Horstmann AS Thermoplus AS1 Operation Manual

Page 1
TThhee HHoorrssttmmaannnn TThheerrmmooPPlluuss AASS11 -- PPrrooggrraammmmaabbllee RRoooomm TThheerrmmoossttaatt
Offers a number of pre-installed heating profiles which are simple to set-up by the installer or user to provide maximum comfort. Once complete, user operations are kept to a minimum by using the +/ - and Warm/Cool buttons on the front of the unit.
TTHHEERRMMOOPPLLUUSS AASS11
LEAFLET No P82312
ISSUE 1
Horstmann Controls Limited
Bristol
BS4 1UP
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
PPLLEEAASSEE NNOOTTEE::
The ThermoPlus contains a selection of five pre-set and one adjustable profile options, one of these profiles should have been set by the Installer to meet your heating requirements. Care should be taken to ensure the correct profile is selected that most suits your lifestyle. Details on how to change the selected profile are located on page 5 of this guide.
PAGE 12 PAGE 1
Page 2
II
NNTTRROODDUUCCTTIIOONN AANNDD OOPPEERRAATTIINNGG GGUUIIDDEE PPAAGGEE 22 WWAARRMM // CCOOOOLL TTEEMMPPEERRAATTUURREE AADDJJUUSSTTMMEENNTT PPAAGGEE 33 PPRROOGGRRAAMMMMIINNGG MMOODDEE PPAAGGEE 44 TTIIMMEE AANNDD DDAATTEE CCHHEECCKK PPAAGGEE 44 SSEETTTTIINNGG PPRROOFFIILLEESS PPAAGGEE 55 HHEEAATTIINNGG PPRROOFFIILLEESS 11 -- 55 PPAAGGEE 66 PPRROOFFIILLEE 66 -- UUSSEERR AADDJJUUSSTTAABBLLEE PPAAGGEE 88 RREESSEETT PPRROOCCEEDDUURREE PPAAGGEE 99 GGEENNEERRAALL IINNFFOORRMMAATTIIOONN PPAAGGEE 1100 SSPPEECCIIFFIICCAATTIIOONN PPAAGGEE 1100
IINNDDEEXXIINNTTRROODDUUCCTTIIOONN AANNDD OOPPEERRAATTIINNGG GGUUIIDDEE
The ThermoPlus AS1 has been designed to be a simple to use thermostat, requiring minimal user intervention. The normal day-to day operation is taken care of by the pre-set heating profiles, any temporary adjustments are simply made by using the + and - buttons. The indicator lights react to any temporary user adjustments made, the LED indicators work in the following way;
Warm is shown by two red lights (6) and Cool is shown by a single blue light (5). The centre button (3) marked 'Warm / Cool' allows you to toggle between warm and cool settings.
When one or more red lights are on, you can increase the temperature by pressing the '+' button (1). For example, press once to go up by 1 degree or press twice to go up by 2 degrees.
When the two or three red lights are on, the temperature can also be lowered by using the '-' button (2). For example, press once to go down to the warm setting temperature and press again to go down to one degree below warm setting temperature.
The Blue light means the unit is working to the lower temperature and the '+' or '-' buttons do not work when this blue light is on. To change to the warm setting press the ‘Warm/Cool’ button.
Under the flap (7) is a Blue button (4). During the summer, or when you want your central heating off for long periods, for example if you go on holiday, press the Blue button and close the flap. When you want to go back to normal operation, open the flap and press the Blue button again, remembering to close the flap once finished.
Both the Warm and Cool temperature settings can be fully adjusted, this operation is detailed opposite
PAGE 2
CCoonnttaacctt ttyyppee::
Micro dis-connection (Voltage Free) CCoonnttaacctt rraattiinngg::
3(1)Amps 230-240V AC
PPoowweerr ssuuppppllyy::
230-240V AC 50Hz
OOppeerraattiinngg TTeemmppeerraattuurree rraannggee::
0
o
C to 40oC
TTeemmppeerraattuurree CCoonnttrrooll RRaannggee::
5oC to 30oC
SSttaannddbbyy TTeemmppeerraattuurree::
5
o
C to 30oC DDoouubbllee iinnssuullaatteedd.. DDiirrtt pprrootteeccttiioonn::
Normal situations.
EEnncclloossuurree pprrootteeccttiioonn::
IP30
PPuurrppoossee ooff ccoonnttrrooll::
Electronic thermostat
RReesseerrvvee BBaatttteerryy TTyyppee::
Lithium
CCaassee mmaatteerriiaall::
Thermoplastic, flame retardant
DDiimmeennssiioonnss::
120mm x 90mm x 32mm
DDiissppllaayy: UUsseerr
- LED
PPrrooggrraammmmiinngg
- Liquid crystal, Backlit
CClloocckk::
24 hour
DDiissppllaayy ttiimmee aaddjjuussttmmeenntt::
1 Minute steps
SSwwiittcchheedd ttiimmee aaddjjuussttmmeenntt::
15 Minute steps
PPrrooggrraammmmee sseelleeccttiioonn::
Auto, Standby
OOppeerraattiinngg ppeerriiooddss ppeerr ddaayy ((WWaarrmm))::
3
OOvveerrrriiddee::
Instant Warm/Cool
BBaacckkppllaattee::
Industry Standard Backplate
SSPPEECCIIFFIICCAATTIIOONN TTHHEERRMMOOPPLLUUSS AASS11
PAGE 11
Page 3
1
4
2
3 5
6
78
PAGE 3
WWAARRMM AANNDD CCOOOOLL TTEEMMPPEERRAATTUURREE AADDJJUUSSTTMMEENNTTSS
The ThermoPlus has two preset temperature levels, these are known as ‘Warm’, higher level temperature(21oC) and ‘Cool’, lower or set back temperature(15oC). The preset temperatures have been selected to give a comfortable, safe, yet efficient temperature level in the home. In certain installations it may be necessary to adjust either the ‘Warm’ and / or ‘Cool’ temperatures to meet the specific needs of the user. This can be achieved by following the simple steps below; (Additional information is also contained within the General Information section of this guide)
PAGE 10
FFRROOSSTT PPRROOTTEECCTTIIOONN
The Blue button situated under the flap will initiate the frost protection mode when pressed, the word ’STANDBY’ will appear on the display, the thermostat has been pre-programmed with a frost protection temperature level of 7
o
C, this can be adjusted by using the up and down
arrow buttons.
BBAATTTTEERRYY
The programmer is fitted with a non-rechargeable, long life battery, which will maintain the programmed time settings for a minimum of 12 months with the supply disconnected. THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the LCD display and LED indicators will not function.
SSEERRVVIICCEE AANNDD RREEPPAAIIRR
The ThermoPlus AS1 is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE THERMOSTAT section of this user guide located on page 9. If this fails to resolve the problem please contact a local heating engineer or a qualified electrician.
Page 4
TTHHEERRMMOOPPLLUUSS PPRROOGGRRAAMMMMIINNGG MMOODDEE
The ThermoPlus AS1 has been designed for minimal user intervention, however should any changes be required please press buttons 4 and 8 simultaneously to enter the programming mode, this will allow you to;
-- CChheecckk tthhee ccuurrrreenntt ttiimmee//ddaattee//yyeeaarr
-- CChheecckk tthhee ccuurrrreenntt pprrooffiillee
TTIIMMEE AANNDD DDAATTEE CCHHEECCKK
The ThermoPlus thermostat has been pre-set with the current time and date during manufacture. No alteration should be required to the time and date, however if any modification is required please refer to the flowchart below.
8
4
-- SSeett aa nneeww pprree--sseett pprrooffiillee oorr
-- SSeett aa uusseerr ddeeffiinneedd pprrooffiillee
PPLLEEAASSEE NNOOTTEE;;
Upon completion of the instructions above, please ensure that you exit the programming mode by pressing button 4 and 8 simultaneously.
GGEENNEERRAALL IINNFFOORRMMAATTIIOONN
- On the ThermoPlus AS1 press the ‘UP’ and ‘DOWN’
arrow buttons together:
- Then release the buttons and the thermostat will
return to preset factory settings.
RREESSEETTTTIINNGG TTHHEE TTHHEERRMMOOPPLLUUSS AASS11
TO RESET PRESS
RREESSEETT PPRROOCCEEDDUURREE
PPLLEEAASSEE NNOOTTEE;;
Using this procedure will restore the ThermoPlus to the original factory
programme settings, the time setting will also default to
11sstt JJaannuuaarryy 22000055
.
Electronic equipment can in some circumstances be affected by electrical interference. If the
display becomes frozen or scrambled; or if you wish to revert back to the default settings please
use the following procedure.
RREESSEETTTTIINNGG TTHHEE TTHHEERRMMOOPPLLUUSS AASS11
WWAARRMM AANNDD CCOOOOLL TTEEMMPPEERRAATTUURREE AADDJJUUSSTTMMEENNTT
The Warm and Cool target temperature settings on the ThermoPlus AS1 are fully adjustable. To change a target temperature it is first necessary to press the the centre button to bring up the ‘Warm’ or ‘Cool’ setting (Indicated by the red or blue LED indicators). By using the up/down keys under the flap the ‘Warm/Cool’ temperature can be increased or decreased to the desired temperature setting
PLEASE NOTE - it is not possible to set the warm setting to below that of the cool setting or vice versa. Once a new temperature has been set on either the Warm or Cool setting the AS1 will continue to use this setting until the next manual adjustment.
PLEASE NOTE - The AS1 will display any temporary change the user has made by pressing the + or - buttons, this does not indicate a permanent change in either the Warm or Cool settings, the temperature will return to the pre-set levels at the next switching period. During an override the ‘Warm’ or ‘Cool’ setting will not be displayed on the LCD.
To Increase
Press
To Decrease
Press
Press
Here Select
PAGE 9
(DETAILS GIVEN ABOVE)
PAGE 4
Page 5
SSEETTTTIINNGG HHEEAATTIINNGG PPRROOFFIILLEESS
The ThermoPlus contains a selection of five pre-set and one user definable profile options, one of these may have been set by the Installer. Care should be taken to ensure a profile is selected that suits the lifestyle of the user concerned. The flow chart below is designed to easily guide you through the process of setting the required profile.
Profiles one to five are detailed on page 6 and 7.
If none of the pre-set profiles meets your requirements it is possible to set a user defined profile, full details are given on page 8.
PPrrooffiilleess oonnee ttoo ffiivvee hhaavvee ffiixxeedd pprrooggrraammmmeess,, tthheeyy ccaann bbee rreevviieewweedd bbyy pprreessssiinngg tthhee sseett bbuuttttoonn oonnccee tthhee sseelleeccttiioonn pprroocceessss ddeettaaiilleedd aabboovvee hhaass bbeeeenn ccoommpplleetteedd.. TToo sseett aa ccuussttoomm pprrooffiillee pplleeaassee rreeffeerr ttoo tthhee iinnssttrruuccttiioonnss oonn ppaaggee 88..
PAGE 5
PPRROOFFIILLEE SSIIXX
UUSSEERR DDEEFFIINNAABBLLEE -- 77 DDAAYY PPRROOGGRRAAMMMMIINNGG
Profile six will allow you to set up a profile to your exact requirements. By using the flow chart below you can adjust the Warm/Cool timing periods on each day of the week.
CCOOPPYY FFEEAATTUURREE TThhee ccooppyy ffeeaattuurree ccaann bbee uusseedd ttoo aappppllyy cchhaannggeess mmaaddee ffrroomm oonnee ddaayyss pprrooggrraammmmiinngg ttoo tthhee nneexxtt.. TThhiiss iiss aacchhiieevveedd bbyy pprreessssiinngg tthhee ddoowwnn aarrrrooww bbuuttttoonn wwhheenn SSEETT iiss ddiissppllaayyeedd oonn tthhee ssccrreeeenn.. SSEETT iiss ddiissppllaayyeedd aafftteerr tthhee llaasstt ccooooll ppeerriioodd iiss ccoonnffiirrmmeedd oonn eeaacchh ddaayy..
PAGE 8
PPRROOFFIILLEE
6
77 DDAAYY
Page 6
The ThermoPlus has six heating profiles, five are fixed and one is adjustable. Profile ‘
OONNEE
’ has been set as the default and is detailed below. During installation a heating profile should have been set to best match your requirements, illustrations of the pre-set profiles are shown below.
HHEEAATTIINNGG PPRROOFFIILLEESS
PPRROOFFIILLEE OONNEE -- DDEEFFAAUULLTT SSTTAARRTT SSTTAATTUUSS
EVERY DAY
0066::0000 WWAARRMM 22:00 COOL
PPRROOFFIILLEE TTWWOO SSTTAARRTT SSTTAATTUUSS
EVERY DAY
0066::0000 WWAARRMM 08:00 COOL 1177::0000 WWAARRMM 22:30 COOL
PPRROOFFIILLEE TTHHRREEEE SSTTAARRTT SSTTAATTUUSS
EVERY DAY
0066::0000 WWAARRMM 08:00 COOL 1111::3300 WWAARRMM 13:30 COOL 1177::0000 WWAARRMM 22:30 COOL
PPRROOFFIILLEESS OONNEE TTOO TTHHRREEEE
2244 HHOOUURR -- SSAAMMEE PPRROOFFIILLEE EEAACCHH DDAAYY
Time
Profile
Warm Cool
5678123491011121314151617181920212223
00
TIME PROFILE
TEMP ERATURE PROFI LE
Time
Profile
Warm Cool
22
23
TEMP ERATURE PROFI LE
18192021141516
17
TIME PROFILE
12345670089101112
13
Time
Profile
Warm Cool
00
TEMP ERATURE PROFI LE
1819202114
15
TIME PROFILE
1234567222389101112131617
PPRROOFFIILLEE
1
PPRROOFFIILLEE
2
PPRROOFFIILLEE
3
PAGE 6
PPRROOFFIILLEE FFOOUURR SSTTAARRTT SSTTAATTUUSS SSTTAARRTT SSTTAATTUUSS MON - FRI
0066::0000 WWAARRMM
SAT/SUN
0077::0000 WWAARRMM 08:00 COOL 22:00 COOL 1111::3300 WWAARRMM 13:30 COOL 1177::0000 WWAARRMM 22:30 COOL
PPRROOFFIILLEE FFIIVVEE SSTTAARRTT SSTTAATTUUSS SSTTAARRTT SSTTAATTUUSS MON - FRI
0066::0000 WWAARRMM
SAT/SUN
0077::0000 WWAARRMM 08:00 COOL 22:00 COOL 1177::0000 WWAARRMM 22:30 COOL
PPRROOFFIILLEESS FFOOUURR AANNDD FFIIVVEE
55 DDAAYY // 22 DDAAYY -- DDIIFFFFEERREENNTT WWEEEEKKDDAAYY // WWEEEEKKEENNDD PPRROOFFIILLEE
Time Profile
MON- FRI
SAT / SUN
MON- FRI
Warm Cool
SAT / SUN
Warm Cool
TEMP ERATURE PROFI LE
22230018192021141516171011121367892345
TIME PROFILE
1
Time Profile
MON- FRI
SAT / SUN
MON- FRI
Warm Cool
SAT / SUN
Warm Cool
TIME PROFILE
1234567891011121314151617181920212223
00
TEMP ERATURE PROFI LE
Profiles one to five have fixed periods, no alteration to the Warm/Cool times can be made, if it is necessary to make any alterations then profile six must be used. Profile six will allow you to set up a profile to your exact requirements. Please refer to the flowchart on page 8.
PPRROOFFIILLEE
4
PPRROOFFIILLEE
5
PAGE 7
2244 HHRR
2244 HHRR
2244 HHRR
55//22 DDAAYY
55//22 DDAAYY
Loading...