MAN0897-01 Specifications / Installation
1 GENERAL SPECIFICATIONS
Storage
Temperature
Operating
Temperature
Free from corrosive
Atmosphere
Vibration
Frequency Acceleration Amplitude
10 ≤ f < 57 Hz
57 ≤ f ≤ 150 Hz
Frequency Acceleration Amplitude
10 ≤ f < 57 Hz
57≤ f ≤ 150
Hz
Shocks
Maximum shock
acceleration
Duration Time 11 ms.
Pulse Wave Half sine wave pulse (3 times in each of X, Y, Z directions)
Noise Immunity
Square wave
impulse noise
Electrostatic
Discharge
Radiated
electromagnetic
field
Fast Transient
Burst Noise
excessive dust
General Specifications
-25° to 70° C
0° to 55° C
gases and
Occasional Vibration
- 0.075 mm
2
9.8 m/s
{1G} -
Continuous Vibration
- 0.035 mm
2
{0.5G} -
4.9 m/s
Severity
level
Voltage 2 kV 1 kV 0.25 kV
Operating
and Storage
Humidity
Pollution
degree
Cooling
method
147 m/s
AC: ± 1,500VDC
DC: ± 900VDC
Voltage: 4kV (contact discharge)
27 – 500MHz, 10V/m
All power
modules
Digital I/Os
(Ue ≥24V)
SmartStixTM HE559DQM602
Remote I/O for the OCS/RCS Family
16 Relay Outputs (250VAC, 30VDC, 2.0A
5 to 95% Non-condensing
2 or lower
Self-cooling
Sweep
Count
10 times in each
direction for
X,Y,Z
Sweep
Count
10 times in each
direction for
X,Y,Z
2
{15G}
Digital I/Os
(Ue < 24 V)
Analog I/Os
Communication
I/Os
2 DIMENSIONS
a. DQM602
0.18 [4.6mm]
1.97 [49.9mm]
1.62 [41.1mm]
6.61 [167.9mm]
6.95 [176.5mm]
b. Terminal Strips
0.31
1.87
HE559-With Removable
Strip
3 NETWORK CABLE
For detailed wiring information, refer to the Control Station Hardware Manual. A
handy checklist is provided that covers panel box layout requirements and minimum
clearances. See Section 10 for our web address.
Pin Description
RED 1 V+
WHT 2 CAN_H
NC 3 No Connection
BLU 4 CAN_L
BLK 5 V-
4 ID SWITCHES (SETTING CSCAN NETWORK IDs)
CsCAN Network IDs are set using the hexadecimal number system from 01 to FD. The
decimal equivalent is 1-253. Refer to Section 8, which shows the decimal equivalent of
hexadecimal numbers. Set a unique Network ID by inserting a small Phillips screwdriver
into the two identical switches. Note: The CsCAN Baud Rate for SmartStix I/O is fixed at
125KBaud.
Power and Diagnostic
LEDs
SmartStix I/O
SmartStix I/O
Use this switch to set the
High Digit –has an x16
multiplier.
MS
MS
Recommended Cable
Thick:
(Max Distance =
500m)
Thin:
(Max Distance =
100m)
NS PWR
NS PWR
Belden 3082A
Belden 3084A
Use this switch to set
the Low Digit – has
an x1 multiplier.
LO (x1)HI (x16)
LO (x1)HI (x16)
I/O Status LEDs
INPUTS
INPUT
2 1 4 5 6 7 8 113 9 12 13 14 15 1610
2 1 4 5 6 7 8 113 9 12 13 14 15 1610
Close-up of Switches
006DIM001
5 LEDs
a. Diagnostic LED Indicators
Diagnostic LED State Meaning
MS: (indicates fault status of
Module )
NS: (indicates fault status of
Network)
b. Status LED Indicators
The Power Status LED illuminates Red when power is applied to the module. There are
I/O Status LED indicators for each of the Digital I/O points, which illuminate Red when an
I/O point is ON.
Solid Red RAM or ROM test failed
Blinking Red I/O test failed
Blinking Green Module is in power-up state
Solid Green Module is running normally
Solid Red Network Ack or Dup ID test failed
Blinking Red Network ID test failed
Blinking Green
Solid Green Network is running normally
Module is in Life Expectancy default
state
______________________________________________________________________________________________________
03/02/2009 Page 1 of 2 ECN # 952

MAN0897-01 Specifications / Installation
6 WIRING
DQM602 Relay Outputs
Number of output points 16
Commons per Module 2
Rated Load Voltage
Rated Voltage
Internal power
Consumption (mA)
24VDC,
220VAC
11 – 25
VDC
550mA
220VAC
OR
24VDC
N
L
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
220VAC
OR
24VDC
N
L
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
7 INTERNAL WIRING
I/O Connector
Field
Side
C1
Q1
SmartStix
Specification for transient voltage suppressors (transorbs) used on output circuitry is
400VDC, bi-directional 400 watts.
Electro-mechanical relays comply with IEC1131-2.
Minimum load voltage /
current
Maximum Load Current
(resistive)
OFF to ON Response 10ms. Max.
ON to OFF Response 12ms. Max.
Output Type N.O.
Weight 9.91oz. (281 g)
FG
NC
NC
NC
Q1
C1
Q4
Q5
C1
Q8
NC
Q9
C2
Q12
Q13
C2
Q16
NC
NC
006DQM008-R1
NC
NC
NC
NC
Q10
Q11
Q14
Q15
Pin
NC*
FG Frame Ground
NC*
NC No Connection
NC No Connection
NC
NC No Connection
NC No Connection
Q2
NC No Connection
NC No Connection
Q3
Q1 Output 1
Q2 Output 2
C1
Q6
Q7
C1
C1
C2
C2
C2
C1 Common 1
Q3 Output 3
Q4 Output 4
C1 Common 1
Q5 Output 5
Q6 Output 6
C1 Common 1
Q7 Output 7
Q8 Output 8
C1 Common 1
NC No Connection
C1 Common 1
Q9 Output 9
Q10 Output 10
C2 Common 2
Q11 Output 11
Q12 Output 12
C2 Common 2
Q13 Output 13
Q14 Output 14
C2 Common 3
Q15 Output 15
Q16 Output 16
C2 Common 2
NC No Connection
C2 Common 2
NC No Connection
-
5VDC / 1mA
2.0A per channel
5.0A per common
Signal
DQM602
No Connection
(*Do not Connect)
No Connection
(*Do not Connect)
To
Controller
+
9 INSTALLATION / SAFETY
8 DECIMAL (DEC) TO HEXADECIMAL (HEX) CONVERSION TABLE
Dec Hex Dec Hex Dec Hex
HI LO HI LO HI LO
0 0 0 86 5 6 172 A C
1 0 1 87 5 7 173 A D
2 0 2 88 5 8 174 A E
3 0 3 89 5 9 175 A F
4 0 4 90 5 A 176 B 0
5 0 5 91 5 B 177 B 1
6 0 6 92 5 C 178 B 2
7 0 7 93 5 D 179 B 3
8 0 8 94 5 E 180 B 4
9 0 9 95 5 F 181 B 5
10 0 A 96 6 0 182 B 6
11 0 B 97 6 1 183 B 7
12 0 C 98 6 2 184 B 8
13 0 D 99 6 3 185 B 9
14 0 E 100 6 4 186 B A
15 0 F 101 6 5 187 B B
16 1 0 102 6 6 188 B C
17 1 1 103 6 7 189 B D
18 1 2 104 6 8 190 B E
19 1 3 105 6 9 191 B F
20 1 4 106 6 A 192 C 0
21 1 5 107 6 B 193 C 1
22 1 6 108 6 C 194 C 2
23 1 7 109 6 D 195 C 3
24 1 8 110 6 E 196 C 4
25 1 9 111 6 F 197 C 5
26 1 A 112 7 0 198 C 6
Warning: To protect the module and associated wiring from load faults, use external
Warning: Connecting high voltage to any I/O pin may cause high voltage to appear
Warning: Wiring the line side of the AC source to loads connected to outputs 0
10 TECHNICAL ASSISTANCE
For assistance and manual updates, contact Technical Support at the following locations:
North America:
Tel: 317 916-4274
Fax: 317 639-4279
Web:
Email:
Cscape, SmartStix and CsCAN are trademarks of Horner APG. This information is
sub
27 1 B 113 7 1 199 C 7
28 1 C 114 7 2 200 C 8
29 1 D 115 7 3 201 C 9
30 1 E 116 7 4 202 C A
31 1 F 117 7 5 203 C B
32 2 0 118 7 6 204 C C
33 2 1 119 7 7 205 C D
34 2 2 120 7 8 206 C E
35 2 3 121 7 9 207 C F
36 2 4 122 7 A 208 D 0
37 2 5 123 7 B 209 D 1
38 2 6 124 7 C 210 D 2
39 2 7 125 7 D 211 D 3
40 2 8 126 7 E 212 D 4
41 2 9 127 7 F 213 D 5
42 2 A 128 8 0 214 D 6
43 2 B 129 8 1 215 D 7
44 2 C 130 8 2 216 D 8
45 2 D 131 8 3 217 D 9
46 2 E 132 8 4 218 D A
47 2 F 133 8 5 219 D B
48 3 0 134 8 6 220 D C
49 3 1 135 8 7 221 D D
50 3 2 136 8 8 222 D E
51 3 3 137 8 9 223 D F
52 3 4 138 8 A 224 E 0
53 3 5 139 8 B 225 E 1
54 3 6 140 8 C 226 E 2
55 3 7 141 8 D 227 E 3
56 3 8 142 8 E 228 E 4
57 3 9 143 8 F 229 E 5
58 3 A 144 9 0 230 E 6
59 3 B 145 9 1 231 E 7
60 3 C 146 9 2 232 E 8
61 3 D 147 9 3 233 E 9
62 3 E 148 9 4 234 E A
63 3 F 149 9 5 235 E B
64 4 0 150 9 6 236 E C
65 4 1 151 9 7 237 E D
66 4 2 152 9 8 238 E E
67 4 3 153 9 9 239 E F
68 4 4 154 9 A 240 F 0
69 4 5 155 9 B 241 F 1
70 4 6 156 9 C 242 F 2
71 4 7 157 9 D 243 F 3
72 4 8 158 9 E 244 F 4
73 4 9 159 9 F 245 F 5
74 4 A 160 A 0 246 F 6
75 4 B 161 A 1 247 F 7
76 4 C 162 A 2 248 F 8
77 4 D 163 A 3 249 F 9
78 4 E 164 A 4 250 F A
79 4 F 165 A 5 251 F B
80 5 0 166 A 6 252 F C
81 5 1 167 A 7 253 F D
82 5 2 168 A 8 254 F E
83 5 3 169 A 9 255 F F
84 5 4 170 A A
85 5 5 171 A B
a. All applicable codes and standards need to be followed in the installation of
this product.
b. For I/O wiring (discrete), use the following wire type or equivalent: Belden
8441 or equivalent.
c. For detailed installation information, refer to Chapter Two in the Control
Station Hardware Manual (MAN0227). A
handy checklist is provided that
covers panel box layout requirements and minimum clearances.
Warning: Consult user
documentation.
Warning: Electrical Shock Hazard.
fuse (5 A).
at other I/O pins.
through 15 and the neutral side of the AC source to the output common(s)
would create a Negative Logic condition, which may be considered an
unsafe practice.
Europe:
Tel: +353-21-4321266
Fax: +353-21-4321826
http://www.heapg.com
techsppt@heapg.com
Web:
http://www.horner-apg.com
Email: tech.support@horner-apg.com
ect to change without notice.
______________________________________________________________________________________________________
03/02/2009 Page 2 of 2 ECN # 952