Table of Contents
RAPiD® Safe Setup and Operation
Warnings and Important Information ................................................. Page 2
Items Included........................................................................................ Page 3
Setup and Operation ............................................................................. Page 4
Warranty .................................................................................................. Page 9
Product Registration and Service ...................................................... Page 10
Frequently Asked Questions ............................................................... Page 10
Mounting Template ............................................................................... Page 11
Items included with your RAPiD® Safe
1. RAPiD® Safe 2600 or RAPiD® Safe 2700
2. Wall Power Supply
3. One (1) RFID Wristband (No. 98164)
4. Two (2) RFID Stickers (No. 98168)
5. One (1) RFID Key Fob Tag (No. 98167)
6. Two (2) Circular Barrel Keys
7. Security Cable
Not Pictured:
• Owner’s Manual
1
• Warranty Card
2
6
Congratulations on purchasing the technologically advanced RAPiD® Safe.
You have taken a significant step in securing the safety of your handgun.
To achieve the best experience with your RAPiD® Safe, please read all
instructions carefully, and understand its operation.
After the RAPiD® Safe has been taken out of the box, please check to be sure
both circular barrel keys fit and unlock your RAPiD® Safe. Contact Hornady®
at 800-338-3220 if the keys do not work. Store keys in a secure location
outside the safe.
How to Program Your
RFID Tags
Your RAPiD® Safe includes three (3)
styles of RFID tags, including:
• 1 Wristband
• 1 Key Fob
• 2 Stickers
*Additional styles and sizes can be
purchased separately.
The RAPiD® Safe can store up to 5 tags.
To program these tags:
1. Open the RAPiD Safe with either the
key or a previously programmed RFID
tag. (The safe does not ship with preprogrammed RFID tags. A RFID tag
must be programmed to work with
this safe.)
4
5
7
RAPiD Safe 2600
Item No. 98175
Exterior: 10.7"x 8.7" x 2.9"
Interior: 7.0" x 7.7" x 2.2"
Power : 12 V 1.0A or four (4) A A bat teries
(batteries not included)
1 2
RAPiD Safe 2700
Item No. 98170
Exterior: 12.7" x 8.7" x 2.9"
Interior: 9.0 " x 7.7" x 2.2"
Power: 12 V 1.0A or four (4) AA batteries
(batteries not included)
3
2. Locate the red program button.
Press and release the button to begin
programming a RFID tag. The first
available program location will begin
to blink.
3. Hold the RFID tag within 1" of the
illuminated RFID reader area on the
top of the safe lid. If the programming
was successful, the safe should
beep two times and the available slot
should go from blinking to solid red
for approximately ten seconds.
One to five RFID tags can be programmed
into the safe.
NOTE: If the user attempts to
program a RFID tag that is already
stored into the safe, the safe will
beep 3 times and the RFID tag
will not be programmed into the
duplicate slot. The RFID tag can
only be programmed into one
location.
4. Verify the RFID tag is programmed
by holding the tag over the RFID
reader with the lid open. The motor
should cycle after each scan.
5. If the RFID tag does not program
into the safe, the program function
will time out after ten seconds
and the safe will return to normal
operation. If multiple attempts to
program a RFID tag fails, please
reference the troubleshooting
section.
6. One to five RFID tags can be
programmed into the safe. If there
is an attempt to program a sixth
RFID tag, the safe will not enter
program mode.
Program Button
Batteries
For backup or mobile use, your
safe requires four AA batteries (not
included). Press in the lid’s stop
catches to fully release the lid for easy
battery installation.
To install batteries, remove inner foam
from base and verify AC adapter is
uplugged. Press down on the two lock
tabs and rotate door forward on the
battery compartment. Only use new
high quality AA batteries. Replace all
batteries at the same time.
To check battery level:
1. Disconnect from AC power source.
2. Press and release RFID button
on the lid.
3. The LED light on the RFID reader
button will flash.
a. Flashing Green – Good battery
b. Flashing Yellow – Low battery
c. Flashing Red – Dead battery
4. After 10 seconds the safe will return
to normal operation.
Stop Catches
Foam
Lock Tabs
To remove all tags from safe:
1. Open the RAPiD Safe with either the key or a previously programmed RFID
tag. Locate the red program button. Press and hold the button for 5 seconds to
erase all tags from the safe. All five red LEDs will begin to blink in sequence.
(The safe does not allow individual tags to be removed. They must all be
erased at one time. The intended RFID tags can then be reprogrammed back
into the safe with the instructions above.)
NOTE: To abort the erase procedure, press the RFID button on the lid of the
safe or do not touch anything and the erase procedure will automatically abort
after 10 seconds and return to normal operation. Test RFID tags to confirm they
are operational.
2. To confirm erasing procedure, press and release the program button again. All
5 LEDs will blink 3 times to visually confirm all RFID tags have been removed.
All RFID tags will no longer work until they are programmed back into the safe
with the instructions in the “How to Program Your RFID Tags” section.
3 4
NOTE: Replace batteries every twelve
months or if they become weak.