TARE (<0>
):
The
TARE (<0>
weight of objects that they do not want to include in the total weight calculated
— such as trays or beakers that may be used to contain the item they are
weighing. To use this function:
1.
Place the empty ‘container’ on the weighing tray.
2.
Wait for a stable reading.
3.
Press
Note:
of the container will be displayed as a negative number. Press
return to
) feature is designed to allow the user to compensate for the
ON/OFF
the container is permanently removed from the remainder of the procedure.
key. The unit will now return to zero and the weight value of
When all weight is removed from the weighing tray, the
TARED (<0>
ON/OFF
) value
again to
zero.
AUTO OFF:
This unit comes with an auto-off feature to conserve battery power. The scale
will automatically turn off after approximately 4 minutes of inactivity.
CAUT ION:
Do not place more than the capacity of the scale on the weighing platform.
Excessive weight will overload the scale and cause the display to read E (error)
Abuse of this type can cause damage to the scale and void the warranty.
This scale is a sensitive electronic instrument. Avoid vibrations, strong electrical
or magnetic elds, and rapid changes in humidity or temperature as they can
adversely affect accuracy.
CARE AND MA INTENANCE:
•Avoid lengthy exposure to extreme heat or cold. To achieve optimum functioning,
allow this unit to acclimatize.
•Allow scale a minimum of thirty seconds to warm up before calibration to allow
internal components to stabilize.
•Keep this product clean. Dust, dirt, and moisture can adversely affect the reliability
and accuracy of this scale.
•Vibrations, air currents and proximity to other electronic equipment may affect
accuracy of this product. Avoid disturbing the environmental conditions when
weighing. Be sure weighing is done with scale on a at surface in a sheltered area.
•Handle with care. Although this product is durable, rough treatment may permanently
damage the internal sensor.
•Remember to replace batteries regularly.
.
Hornady Electronic Scale
Instruction Manual
Model GS-
Congratulations on your selection of a quality Hornady product.
With proper care and use, this product will provide years of depend-
able service. Hornady is committed to providing products that t your
needs, manufactured to the highest of quality standards. If you have
any comments or suggestions concerning this product please mail
them to:
Hornady Manufacturing
P.O. Box 1848
Grand Island, NE 68802-1848 USA
Please read all the operating instructions to ensure the best performance from
your Hornady Electronic Scale.
CAPACITY/ACCURACY:
350grain / 23 grams x 0.1grain / 0.01gram
POWER SOURCE:
Two “AA” alkaline batteries
BATTERY INSERTION:
1.
Turn scale upside down and locate battery compartment cover.
2.
Push tab toward compartment cover. Lift cover off.
3.
Insert two “AA” alkaline batteries. ensure that battery polarities are
aligned properly.
4.
Replace battery compartment cover and secure.
5.
The scale is now ready for use.
Note: Do not use excessive force in removing or replacing battery compart ment cover.
350
KEY PAD FUNCTIONS:
ON/O FF Key
a)
Press and hold to turn unit on or off.
b)
Once unit is on, this key operates the tare function. Press to compensate for
the weight of weighing tray or other object.
MODE /CAL Ke y:
a)
Press and hold to begin calibration procedure (see Calibration Procedure).
b)
Press and release to change weight unit, i.e., from grams to grains.
CALI BRATION:
Important: always allow a minimum of thirty seconds for the scan to stabilize.
During prolonged periods of use repeat this procedure at regular intervals for
optimum accuracy.
Note: Any attempt by the end user to internally calibrate the scale will void warranty.
DIGITAL AUTO CALIBRATION PROCEDURE:
1.
Place scale on a at surface in a sheltered area.
2.
Turn scale on by pressing
thirty seconds.
3.
Press and hold
The ashing weight reading indicates the correct weight that must be
placed on the tray.
4.
With the display still ashing, press the
ON/OFF
key. Allow unit to stabilize for at least
CAL
key until the display shows a ashing weight reading.
ON/OFF
key. The display will read
CAL 0.
5.
Wait for
3 seconds
the center of the tray.
6.
When the calibration is complete the unit will briey display
CAL F
and then return to normal operating mode. The calibration is
complete when the display correctly shows the weight that is placed on the
weighing tray and the display has stabilized.
7.
Remove the calibration weight and press the
zero point.
Note: If CAL E appears instead of CAL F, this indicates an error has occurred.
Turn the scale off and repeat the procedure.
and then gently place the correct calibration weight in
TARE (<0>
) key to reset the
OPERATION:
1.
Place scale on a at surface in a sheltered area.
2.
Press and hold the
3.
Open draft shield and place tray on weighing platform. (You may also place
objects directly on the weighing platform.)
4.
Allow the scale to stabilize for at least
the scale will read
5.
Gently place object(s) to be weighed in the weighing tray. Do not overload.
6.
Wait for reading to stabilize.
7.
Read weight.
8.
To change weighing units (from grams to grains) press the
ON/OFF
button to turn the scale on.
8888
before returning to
30 seconds.
zero.
When initially turned on,
MODE/CAL
key.
FEATURES:
DIGITAL AUTO CALIBRATION:
Allows for convenient user digital calibration from the keypad.
POWER UP TEST:
When the unit is initially turned on, all segments of the display will appear. This
will remain for approximately 3 seconds. The scale will then reset to zero. This
is an internal self-test procedure.
RIGH T READI NG INDICATION:
A right facing arrow will appear on the right side of the display to indicate
the weighing mode currently in use. When weight is placed on the tray, this
arrow will disappear while the scale stabilizes and will reappear once the
stable weight reading is achieved.
OVER LOAD:
When a load that exceeds this unit’s capacity is applied to the weighing platform,
an E (error) will appear on the display. Remove this load immediately. The unit
should then return to normal operation unless damage has occurred.
NEGATI VE VALUE RECORD ING:
Any “tared” value or value left in memory will be displayed as a negative
number once all weight is removed from the unit. Press the
return the unit to zero.
TARE (<0>