Horing LIH Industrial Co., LTD. NDKA1, NDKB1 User Manual

Carbon Monoxide
Detector
Model: NDKA1(Standalone) NDKB1(System)
Detector Base
Manual
1.Introduction
2.Source of CO
CO enters the body through breathing. CO poisoning can be confused with flu symptoms, food poisoning and other illnesses. Some symptoms include shortness of breath, nausea, dizziness, light headedness or headaches. High levels of CO can be fatal, causing death within minutes.
The concentration of CO, measured in parts per million (ppm) is a determining factor in the symptoms for an average, healthy adult.
Source: NFPA's Fire Protection Handbook, 20th Edition.
Mounting detector in the house with heating installations, furnaces or garages, such as living room, corridor, kitchen, boiler room, parking lot, basement and so on. Installed quantity should correspond to the room size to make sure the best warning effect.
4.Recommended mounted location
1. Keep a distance of above 1.5m from any heating installations or avoid mounting right above.
2. Avoid mounting in the house with full of dust, pollution, dirt, grease and high humidity.
3. Avoid mounting around air vent, conditioner vent and the ceiling fan.
4. If there are any volatile chemicals in the mounting place, they should be sealed well in case that volatile gas will bring about detector malfunction.If the house is being refurbished and painted, please dismantle the detector and store away. After all is done, please install it back.
A. Hang on wall
Remove/Affix
(Screw to ceiling/wall)
Lock
(twist clockwise to lock)
Open
(twist counterclockwise to open)
Hang on wall
B. Screw
5.Not recommended mounted location
6.Mounting Detector
1.Home: The heating installation, such as hot-water heaters with gas and
gas stoves, is easy to combust incompletely and then produce CO.
3.Fire: Smolder is a kind of incomplete combustion. It often occurs before & after the fire as a disaster and produce a large amount of CO.
The scooters/cars or general machine tools can exhaust fumes with high concentration.
2.Parking lots & garage:
20cm
20cm
Model NDKB1NDKA1 Power Source 12~24V3V DC Standby Current 800uA24uA Alarm Current under 40mAunder 65mA Alarm Sound 85dB/3M and above Relay Output a set of contacts Ambient Temperature -10~50 Dimensions 102mm(Dia.) × 45mm(H.) Weight about 150g Material fire-proof plastic
Carbon monoxide concentration
The underlying symptom
50 ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
No adverse effects with 8 hours of exposure.
200
Mild headache after 2-3 hours of exposure.
400
Headache and nausea after 1-2 hours of exposure.
800
Headache, nausea, and dizziness after 45 minutes; collapse and unconsciousness after 1 hour of exposure.
1,000
Loss of consciousness after 1 hour of exposure.
1,600
Headache, nausea, and dizziness after 20 minutes of exposure.
3,200
Headache, nausea, and dizziness after 5-10 minutes; collapse and unconsciousness after 30 minutes of exposure.
6,400
Headache and dizziness after 1-2 minutes; unconsciousness and danger of death after 10-15 minutes of exposure.
ppm12,800
Immediate physiological effects, unconsciousness and danger of death after 1-3 minutes of exposure.
There is a test button on the surface to test if it is normal or not. And it also can delete detection data.
7.Testing 9.Battery installation/Wiring Diagram
1.The product acts in accordance with CO concentration of EN standard inspection procedure as follows:
There is no need to clean & maintain, please just keep the surface of detectors clean. In normal times, you can press the test button to make sure it is under normal condition.
1. Avoid using detergent or solvent to wipe. Please don’t use water or detergent to wash, either.
2. Keep a certain distance from home appliances with electronic interference.
3. Prohibit from taking down the product to overhaul or make a change to it.
8.Operation
10.Maintenance
11.Warning
CO concentration
30 ppm
50 ppm
100 ppm
300 ppm
120 minutes
60 minutes
10 minutes
90 minutes
40 minutes
3 minutes
Won’t release alarm before the time Release alarm before the time
2. Power indicator: the LED flashes green once every 30 seconds after normally supplying the power.
3. Warm-up time: about 1 minute.
4. Indicator mode:
5.
Reset: when the CO concentration is below 30ppm, detector will reset automatically.
6.
Test button function:
A. Warm-up: flash for 1 second and then go off for 1 second.
A. General operation: Pressing it for alarm test, it will flash green and red and yellow twice every second and 2 beep sounds.
B. Early warning operation: Pressing it can remove the early warning status. But if it detects the CO concentration which meets the requirement of early warning, it will still enter early warning status.
C. Alarm operation: Pressing it can remove the alarm status. But if it detects the CO concentration which meets the requirement of alarm, it will still enter the alarm status.
B. Standby: flash green once every 30 seconds. C. Early warning: flash red once every 10 seconds and 1 beep sound. D. Alarm: flash red 5 times every 5 seconds and 5 beep sounds. E. Fault:
1. Low Power: flash yellow one times every 30 seconds and 1 beep sounds.
2. Expected useful life expire (5 years): flash yellow two times every 30 seconds and 2 beep sounds.
3. Sensor malfunction: yellow light ON continuously and 2 beep sounds.
*Prior to determining the action will enter the early warning mode multiple judgments, confirmed after entering the action mode.
20cm
TEST BUTTON
NDKA1(Standalone)-Battery installation
NDKB1(System)-Wiring Diagram
20cm
1O.NDKA1.M51 Ver.A0
Black line (POSITIVE)
Red line (NEGATIVE)