Horiba B-741, B-742, B-743 Operating Manual

CODE:GZ0000297062
Refer to page 7 to page 27 for detailed instructions.
Preface
This manual describes the operation of the COMPACT NO Be sure to read this manual before using the product to ensure proper and safe operation of the instrument. Also safely store the manual so it is readily available whenever necessary.
Product specifications and appearance, as well as the contents of this manual are subject to change without notice.
J Warranty and Responsibility
HORIBA, Ltd. warrants that the Product shall be free from defects in material and workmanship and agrees to repair or replace free of charge, at option of HORIBA, Ltd., any malfunctioned or damaged Product attributable to responsibility of HORIBA, Ltd. for a period of one (1) year from the delivery unless otherwise agreed with a written agreement. In any one of the following cases, none of the warranties set forth herein shall be extended;
z Any malfunction or damage attributable to improper operation z Any malfunction attributable to repair or modification by any person
not authorized by HORIBA, Ltd.
z Any malfunction or damage attributable to the use in an
environment not specified in this manual
z Any malfunction or damage attributable to violation of the
instructions in this manual or operations in the manner not specified in this manual
z Any malfunction or damage attributable to any cause or causes
beyond the reasonable control of HORIBA, Ltd. such as natural disasters
z Any deterioration in appearance attributable to corrosion, rust, and
so on
z Replacement of consumables such as the sensor and standard
solutions
HORIBA, LTD. SHALL NOT BE LIABLE FOR ANY DAMAGES RESULTING FROM ANY MALFUNCTIONS OF THE PRODUCT, ANY ERASURE OF DATA, OR ANY OTHER USES OF THE PRODUCT.
-
METER, B-74X.
3
August, 2012 © 2012 HORIBA, Ltd.
J Trademarks
Generally, company names and brand names are either registered trademarks or trademarks of the respective companies. (R), (TM) symbols may be omitted in this manual.
z OnGuard is a registered trademark or trademark of DIONEX
corporation in the United States and other countries.
Regulations
J Conformable Directive
This equipment conforms to the following directives and standards:
Directives: the EMC Directive 2004/108/EC Standards: [the EMC Directive] EN61326-1:2006
Q Information on Disposal of Electrical and Electronic
Equipment and Disposal of Batteries and Accumulators
The crossed out wheeled bin symbol with underbar shown on the product or accompanying documents indicates the product requires appropriate treatment, collection and recycle for waste electrical and electronic equipment (WEEE) under the Directive 2002/96/EC, and/or waste batteries and accumulators under the Directive 2006/66/EC in the European Union. The symbol might be put with one of the chemical symbols below. In this case, it satisfies the requirements of the Directive 2006/66/EC for the object chemical. This product should not be disposed of as unsorted household waste. Your correct disposal of WEEE, waste batteries and accumulators will contribute to reducing wasteful consumption of natural resources, and protecting human health and the environment from potential negative effects caused by hazardous substance in products. Contact your supplier for information on applicable disposal methods.
Class B, Portable test and measurement equipment
J FCC Rules
iἽ ὤὤ Oᴴ㥉㟝 ⵝ㋕䋩㐔ὤ㣄㣠P
Any changes or modifications not expressly approved by the party responsible for compliance shall void the user's authority to operate the equipment.
Q WARNING
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
J Korea Certification
Q
㢨 ὤὤ⏈ ᴴ㥉㟝OiἽPG㤸㣄䑀㤵䚝ὤὤ⦐㉐ 㨰⦐ ᴴ㥉㜄㉐ ㇠㟝䚌⏈ ᶷ㡸 ⯝㤵㡰⦐ 䚌⮤SG⯜☔ 㫴㜡㜄㉐ ㇠㟝䚔 ㍌ 㢼㏩⏼␘U
J Taiwan Battery Recycling Mark
Contents
1 Introduction.......................................................................................... 1
1.1 Items in package .........................................................................1
1.2 Consumable parts sold separately ..............................................2
2 Part Names and Functions ................................................................. 3
3 Handling Precautions.......................................................................... 5
4 Basic Handling..................................................................................... 7
4.1 Inserting/removing batteries ........................................................7
4.2 Attaching/detaching the sensor ................................................... 8
4.3 Power ON/OFF ............................................................................9
4.4 Storage ........................................................................................9
5 Calibration.......................................................................................... 10
5.1 About calibration ........................................................................10
5.2 One-point calibration in high concentration ...............................11
5.3 One-point calibration in low concentration .................................11
5.4 Two-point calibration .................................................................12
6 Measurement...................................................................................... 13
6.1 Sample setting ...........................................................................13
6.2 Measurement operations ...........................................................16
7 Special Setting Mode......................................................................... 17
7.1 Measurement unit setting ..........................................................19
7.2 Temperature display mode ........................................................20
7.3 Calibration point setting .............................................................21
7.4 Multiplying compensation setting ...............................................22
7.5 Adding compensation setting ....................................................23
7.6 Sensor voltage display mode ....................................................24
7.7 Low calibration value setting .....................................................25
7.8 Initialization mode ......................................................................27
7.9 Software version display mode ..................................................27
8 Appendix ............................................................................................ 28
8.1 Frequently asked questions .......................................................28
8.2 Specifications ............................................................................31
8.3 Interfering ions ...........................................................................32
1 Introduction
The COMPACT NO sensor and enables accurate measurement of nitrate ion (NO tions from a single drop of a sample.
1.1 Items in package
Meter model
Sensor S040 1 1 1
Meter
Storage case 1 1 1 Carrying case Batteries CR2032 2 2 2
Dedicated stan­dard solutions
Pipette 5 5 1 Washing bottle 250 mL 1 1 ­Squeezer 1 - ­Medical cup For diluting 3 - ­Extraction bottle - 3 ­Spoon for soil sampling - 2 ­Sampling sheet holder cover - 2 -
Sampling sheet B Tweezers - 1 -
Instruction manual Common 1 1 1
-
METER B-74X incorporates HORIBA original flat
3
B-741
for crops
B-741 1 - ­B-742 - 1 ­B-743 - - 1
For B-741 1 - ­For B-742 - 1 -
-
30 ppm
NO
3
-
150 ppm
NO
3
-
300 ppm
NO
3
-
2000 ppm
NO
3
-
5000 ppm
NO
3
100 sheets 5 sheets
-1-
--1
11 -
--1
1- -
-1-
--1
B-742
for soil
-
) concentra-
3
for geneal-use
B-743
1
Meter model
B-741
for crops
B-742
for soil
B-741 1 - -
Quick-start manual
B-742 - 1 ­B-743 - - 1
1.2 Consumable parts sold separately
Part No. Name Type Application
3200459870 Sensor 3200053535
S040NO Y044, NO
3200053536 Y045, NO 3200053514 Y042, NO
Standard
solutions 3200053532 Y043, NO 3200053433 Y041, NO
3200459736
3200053858
Sampling sheet
holder cover
Sampling
sheet B
Y048
Y046, 100 sheet pack
-
3
-
30 ppm B-742 (low conce ntration)
3
-
150 ppm B-743 (low concentration)
3
-
300 ppm
3
-
2000 ppm B-743 (high concentration)
3
-
5000 ppm B-741 (high concentration)
3
B-741B-742B-743
B-741 (low concentration) , B-742 (high concentration)
B-711, B-712, B-713, B-721, B-722, B-731, B-741, B-742, B-743, B-751
B-711, B-712, B-713, B-721, B-722, B-731, B-741, B-742, B-743, B-751
B-743
for geneal-use
2
2 Part Names and Functions
9
10
11
12
13
14
15
A
B
1
2
3
4
5
6
7
8
No. Name Description
1 Flat sensor
2 Light shield cover
3 Lithium batteries CR2032 (u2)
4 MEAS switch
5 ON/OFF switch Turns ON/OFF the meter. 6 CAL switch 7 Waterproof gasket Makes the meter waterproof.
Place a sample on this sensor. This sensor consists of a liquid junction (A) and response membrane (B). Both A and B must be covered with the sample.
Shields the sensor from light, which affects the sensor. Close the light shield cover before starting measurement. If using the sampling sheet holder cover (refer to page 15), shield the flat sensor from light with an alternative.
Switches the calibration mode to the measurement mode, activates/deactivates the reading locking function in the measurement mode, and starts/applies settings in the special setting mode.
Starts calibration, and switches items/settings in the special setting mode.
3
No. Name Description
8 Strap eyelet A strap can be attached here.
9 MEAS icon
10 CAL icon
11 Battery alarm icon
T emperature alarm
12
icon
13 Stability icon Lights up when the measured value is stabilized.
Measured value
14
display
Measurement unit
15
display
Blinks until the measured value is stabilized, and lights steadily when the measured value is settled, while the reading locking function is active.
Blinks during calibration, and lights steadily when calibration is finished.
Lights up when the batteries are low and need to be changed.
Blinks when the measuring environment temperature does not meet the specified operating temperature (5qC to 40qC).
Displays a measured, set, or status value. A unit symbol lights up corresponding to the valu e displayed
on the measured value display (14). “ppm NO
concentrations. “ppm NO selectable for nitrate nitrogen concentrations.
Furthermore, kg/10a can be set for B-742 (refer to page 19). The default setting is “pm NO
-
” or “mg/L NO
3
-
” is selectable for nitrate ion
3
-
-N” or “mg/L NO
3
-
”.
3
-
3
-N” is also
4