Platinum
Central Vacuum Systems
Systèmes d’aspiration
centrale Platinum
Power Canisters
Aspirateurs centraux
Thank you for selecting a
HOOVER
This cleaner was inspected and packaged carefully before being shipped from the factory. If
you should happen to need assistance during
assembly or operation,
Call 1-800-944-9200 for automated referral of
authorized service outlet locations (U.S. only)
OR
Visit us on-line at
service outlet nearest you (click on the
“Service” button) OR
Call 1-800-263-6376 to speak with a
representative in our Consumer Response
Center.
® product.
hoover.com to find the
Français
➜ p. 8-12
PLEASE DO NOT RETURN THIS
PRODUCT TO THE STORE
.
Merci d’avoir choisi ce
.ca.
®
Cliquez
produit HOOVER
Cet aspirateur a été inspecté et emballé
soigneusement avant d’être expédié depuis
l’usine. Si vous avez besoin d’aide au cours de
l’utilisation ou de l’assemblage de l’appareil,
appelez :
Hoover Canada – 1-800-263-6376
isitez notre site W
V
sur le bouton « Service » pour connaître
l’adresse du Centre de service le plus près de
chez vous
PRIÈRE DE NE PAS RETOURNER
CET APPAREIL AU DÉTAILLANT.
eb au
hoover
Review this manual before operating
Lire attentivement ces instructions
cleaner.
avant d’utiliser l’appareil.
Fill in and retain
The HOOVER Central Vacuum System Power unit will be permanently mounted.
or your records, please enter model and serial numbers in the spaces provided
F
below and retain in a safe place.
ower Unit Model No. _______________ Serial No. _______________________
P
(See side of power unit)
Attach your sales receipt to this owner’s manual. Verification of purchase date
may be required for warranty service.
Important Safeguards!
When using an electrical appliance, always follow basic precautions, including
the following:
Warning:To reduce the risk of fire, electric shock, or injury:
• Do not use on wet surfaces.
• Connect to a properly grounded outlet only. See “Grounding Instructions.”
• Close supervision is necessary when any appliance is used by or near children.
Do not allow cleaning system to be used as a toy or to run unattended at any
time.
• Do not allow any objects to be put into wall inlets.
• Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
• Do not use to pick up flammable or combustible liquids such as gasoline or fine
wood sandings or use in areas where they may be present.
• Do not use without filter in place. Empty dust container and clean filter
frequently when picking up very fine materials such as powder.
• Do not use without filter bag in place on models including a filter bag. Change
bag frequently when picking up very fine materials such as powder.
• Use extra care when cleaning stairs.
• Do not put any objects into openings. Do not use with any openings blocked:
keep free of dust, lint, hair, and anything that may reduce air flow.
• Do not pull or carry by cord, use cord as a handle, close a door on cord or pull
cord around sharp edges or corners. Do not run appliance over cord. Keep
cord away from heated surfaces.
• Always disconnect cord from electrical outlet before servicing the power unit.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Never handle plug or appliance with wet hands.
• Unplug cleaner when not in use. Turn off all controls before unplugging.
• Do not use with damaged cord or plug. If appliance is not working as it should,
has been dropped, damaged, left outdoors, or dropped into water, take it to a
Hoover Sales and Service Center or Authorized Hoover Warranty Service Dealer
(Depot).
• Use vacuum cleaner only for its intended use as described in this owner’s
manual. Use only attachments recommended by Hoover; others may cause
hazards.
When using accessory kits, note these additional
Safeguards:
• Do not use powered nozzle outdoors.
• Keep hair, loose clothing, fingers, feet and all parts of body away from openings, rotating agitator and any other moving parts. Do not operate nozzle in
bare feet or when wearing open toe shoes or sandals.
• Disconnect hose from wall inlet and cord from electrical outlet when not in use
and before servicing motorized nozzle.
• The hose contains electrical wires. Do not use if damaged, cut, or punctured.
Avoid picking up sharp objects.
Always disconnect cord from electrical outlet before connecting or
•
disconnecting hose or motorized nozzle.
2
Save these instructions!
1. Assembly
C
ANAVAC SYSTEMS INC
O
NTARIO, CANADA
LR37447
N
RTL/C
MODEL
120 V
6
0HZ
W
ARNING:
AVERTISSEMENT:
Serial No.
No. Desérie
Mount at least 12 in. from ceiling.
Connect to individual brance circuit.
To reduce the risk of electric shock do not
useoutdoors or on wet surfaces.
Assurer un dégagement d'au moids 12 po. entre les plafond
s
elon les cas.
Brancher a une derivation distincte
P
our reduire les risgues de choc
m
atieres humides.
electrique ne pas utiliser a l'exterieur et ne pas aspiere de
E119989
C
U
L
perate cleaning system only at
O
voltage specified on power unit.
his system is intended for
T
household use.
Grounding
Instructions
This appliance must be grounded. If it
hould malfunction or breakdown,
s
grounding provides a path of least
resistance for electrical current to
reduce the risk of electric shock. This
appliance is equipped with a cord having an equipment-grounding conductor
(A) and grounding plug (B). The plug
must be plugged into an appropriate
outlet (C) that is properly installed and
ounded in accordance with all local
gr
codes and ordinances.
DANGER-
Improper connection of the equipmentgrounding conductor can result in the
risk of electric shock. Check with a
qualified electrician or service person if
you are in doubt as to whether the outlet
is properly grounded.
he plug provided
t
if it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
This appliance is for use on a nominal
120 volt circuit and has a grounding
lug that looks like the plug illustrated in
p
Fig. 1-1.
A
Temporary adapter (D) may be used
to connect this plug to a 2-pole receptacle (E) if a properly grounded outlet is
not available. The
should be used only until a properly
grounded outlet (C) can be installed by
a qualified electrician. The green colored rigid ear (F), lug, or the like extending from the adapter must be connected
to a permanent ground such as a properly grounded outlet box cover.
Whenever the adapter is used, it must
be held in place by a metal screw (G).
The Power Canister can be mounted in
the basement, utility room, garage or
ny other remote area, except where
a
exposed to weather, and convenient to
n electrical outlet. The unit requires
a
ventilation.
roducing or confined area such as the
p
attic, furnace room, etc. If desired, the
ower Canister can be exhausted to the
P
outside.
The top of the Canister should be no
less than 12” (30.5 cm) from the ceiling,
and any corner wall, to allow proper
cooling to the motor. For ease of removing the dust container, the bottom of the
unit should be at least 18” (46 cm)
above the floor.
Central Vacuum Power Canisters require
a separate/dedicated, 120 Volt, 60Hz.,
20 Amp, 3 wire grounded power circuit,
protected by a 120 Volt, 60 Hz., AC, 20
Amp time delay fuse or circuit breaker
and a 120 Volt, 60 Hz., 20 Amp grounded receptacle.
If a 120 volt, 60 Hz., 20 Amp grounded
receptacle is not available, have a quali-
DO NOT install in a heat
fied electrician install one for you. The
receptacle should be no more than 5
feet (152 cm) from the Power Canister.
UNDER NO CIRCUMSTANCES
SHOULD AN EXTENSION CORD BE
USED WITH THIS CANISTER.
Mounting the power
canister
) Determine if the wall you will be
1
ounting the Canister to is block,
m
concrete, or plaster/drywall.
2)
Block or Concrete Wall
You will need (2) 1-1/2” (3.8 cm) x
1/4” (.64 cm) lead plugs and (2) 11/2” (3.8 cm) x 1/4” (.64 cm) lag
bolts. Drill a 1/2” (1.3 cm) dia. x 13/4” (4.4 cm) deep hole with a
masonry drill bit. Insert a lead plug
into the hole.
Mount the bracket (Fig. 2-1) from a
top hole with a lag bolt. Mark the
other upper hole of the bracket.
Make sure that the bracket is
straight. Slide the bracket away
from the mark and drill a hole directly over the mark.
Insert a lead plug into the hole.
Align the bracket over the hole and
tightly fasten with a lag bolt.
Continue to 4).
2-1
Drywall or Plaster Wall
3)
You will need(2) 1-1/2” (3.8 cm) x
1/4” (.64 cm) wood screws. Locate
a stud and drill a 1/8” (.32 cm) dia.
x 1-3/4” (4.4 cm) pilot hole. Mount
the bracket from a top hole with a
wood screw. Make sure that the
bracket is straight. Drill a second
pilot hole using a lower hole on the
bracket and fasten tightly with the
other wood screw.
4) Mount the Power Canister on the
bracket making sure the bar on the
back of the machine is settled to the
bottom of the slots on the mounting
bracket. The wall mounting bracket
must fit between the two brackets
on the back of the central vacuum.
TOP
MOUNTING
RACKET
B
5) Route the intake tubing to the
Canister.
6) Insert the tubing into the Canister
inlet.
7) Tighten the inlet connection with the
3” (7.6 cm) gear clamp (included).
(Do not cement pipe to plastic
inlet port.)
8) When venting the exhaust air, a
noise reducing exhaust muffler (A) is
included, which is installed inline in
the piping to vent outside or it can
be installed to vent indoors as
shown in Fig. 2-2. Connect to the
exhaust (right hand side near to of
unit). Tighten the exhaust connection with the gear clamp (included).
(Do not cement pipe to plastic
exhaust port.)
Connect the 24 Volt wir
9)
om the wall valves into the 24 V
fr
receptacle on the machine.
es coming
olt
2-2
A
10) Plug the power cord in.
11) Assuming that the wall inlet valves
are connected, the system is now
ready.
3. How to use
3-1
A
To start your Power Canister, simply plug
your hose end into any wall inlet valve.
Both types of wall valves (Standard (A) -
ded Hose; Electrified (B) - Cor
Cor
Hose) are shown in Fig 3-1.
B
dless
Hose inlet port
Insert the hose into the hose inlet (A) as
shown in Fig. 3-2. The power unit is
turned ON and OFF with the switch
found on the upper section of the motor
module.
3-2
A
If you have a hose without switches, the
Power Canister will star
hose is inserted into the wall valve.
If you have a hose with a switch, then
the Power Canister can be tur
OFF with the switch.
The Power Canister can also be tur
ON and OFF with the switch found on
the upper section of the motor module.
Check the System
Check each connection for proper seal
and that no air leaks occur. If one is present, you may hear a “hissing” sound.
t as soon as the
ned ON or
ned
4
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.