Hoover F6211-900 Owner’s Manual

f
HOOVER
_ k
_f ENGLISH -_ pp. 1-14 | ESPANOL ,._ pag. 16-24
TM
SteamVac
TM
www.hoover.com ®
including the following:
READ ALL INSTRUCTIONS BEFORE USING APPLIANCE.
WARNING:
To reduce the risk of fire, electric
shock, or injury:
, Use indoors only.
Use only on surfaces moistened by the cleaning process. Do not immerse product.
Connect to a p roperlygrounded Close supervision is necessary outlet only. See Grounding when any appliance is used by or
Instructions '. near children. Do not allow deep
Do not clean over floor electrical unattended at any time.
outlets.
Do not use without tanks in place, or pets.
Use extra care when cleaning on
stairs. Do not place deep cleaner on stairs.
Use deep cleaner only for its intended use as described in the
instructions.
Use only attachments recom-
mended by The Hoover Company; others may cause hazards.
The use of an extension cord is not recommended. If an extension
cord is absolutely necessar), use at least a 16 gauge 3-wire cord which has a 3-prong grounding type plug
and a 3-pole receptacle that accepts the machine plug.
Unplug deep cleaner when not in rettes, matches, or hot ashes. use. Turn off all controls before
unplugging. Avoid picking up hard, sharp
Unplug deep cleaner before con- may damage the machine.
necting the tool.
Always disconnect cord from electri- feet and all parts of body away
cal outlet before servicing the deep from openings and moving parts.
cleaner.
Do not unplug by pulling on
cord. To unplug, grasp the plug, nol
the cord.
Never handle plug or appliance
with wet hands. To help prevent matting and
Do not pull or carry by cord, use until they are dry. Keep children
cord as a handle, close door on cord and pets away from carpets until or pull cord around sharp edges or they are completely dry
corners. Do not run appli'ance over cord. Keep cord away from heated Store in a dry place. Do not ex-
surfaces, pose machine to freezing tempera-
Do not use with dmnaged cord or
plug. If appliance is not working as
it should, has been dropped, dam- aged, left outdoors, or dropped into
water, take it to a Hoover FActory
Service Center or Authorized Hoover Warranty Service Dealer.
cleaner to be used as a toy or to run
Do not point tools toward people
Use only commercially available
Hoover SteamVac TM cleaners intended for machine application.
Do not use any type of wax with deep cleaner.
Keep detergents and other clean-
ers out of chirdren's reach.
Do not use to pick up flammable
or combustible liquids such as
gasoline or use in areas where they may be present.
Do no[ pick up chlorine bleach,
drain cleaner, gasoline or any other
toxic material with this appliance.
Do not pick up anything that is
burning or smoRing, such as ciga-
objects with the deep cleaner. They
Keep hair, loose clothing, fingers,
Do not put any object into open-
ings. Do not use with any opening blocked; keep free of dust, Iint,
hair. and anything that may reduce air flow.
resoiling, avoid contact With carpets
tures.
Grounding
Instructions
B
© ©
C
This appliance must be grounded. If it
should inalfunction or breakdown, grounding provides a path of least resis
tance for electrical current to reduce tile risk of electric shock. This appliance is
equipped with a cord having an equip ment-grounding conductor (C) and grounding plug (A). The plug must [0e plugged into all appropriate outlet (B) that is properly installed and grounded
ill accordance with all local codes and ordinances.
DANGER-
Iinproper connection of the equipment- grounding conductor can result ill tile risk of electric shock. Check with a quali fled electrician or service person if you
are in doubt as to whether the outlet is properly grounded. Do not modify the
plug provided with the appliance if it
will not t_t the outlet, have a proper out-
let installed by a qualified electrician. This appliance is fin" use on a nomilml 120 volt circuit and has a grounding plug that looks like the plug illustrated
in sketch (A).
A temporary adapter (D) may be used to connect this plug to a 2-pole receptacle
(E) if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet (B) call be installed by a qualified electrician. The green cok)red rigid ear, lug, or tile like (F) extending ti'Oln the adapter must be connected to a perma nent ground (G) such as a properly grounded outlet box covm: Whenever the adapter is used, it must be held ill place by a metal screw. NOTE: Ill Canada, the use of a temporary adapter is not permitted by tile Canadian
Electrical Code.
r To contact us:
www.hoover.com
1-800-944-9200 - automated service
dealer locator
1-330-499-9499 - our Consumer Response Center (8 AM to 5 PM
Monday - Friday)
f Fill in and Save
For"your" records, enter the model number and serial numbers in the spaces provided. These
numbers are located on the data label on the back of the cleaner.
Model No. Serial No.
Save your sales receipt and attach it to this manual. Proof of date of purchase may be
Important safeguards ........ 2
Carton contents ............. 3
Cleaner description .......... 4
Deep cleaner basics .......... 5
Filling the tank ............ 5
Emptying the recovery tank . 6
Attaching the hose ......... ?
Using the tool ............. ?
Draining & storing hose .... 8
Cleaning carpet .......... 10-11
Cleaning upholstery ..... 11-12
Basic steps for cleaning ...... ]a
Warranty .................. 14
_,, J
oOus
LISTED
© 2004 The Hoover Company
www.hoover.com
A
Continued ._
15
1. Hand grip
2. Solution trigger: press to release cleaning solution
3. Clean Surge TM button
4. Upper handle
5. Upper handle release button
6. Solution tank cap/measuring cup
7. Solution tank release button
8. Solution tank
9. Brush setting selector
10. Nozzle
11. Recovery tank
12. Recovery tank release button
13. Stair/upholstery tool
14. Recovery tank cap
15. Cord hooks (tool caddy removed)
16. Hose door
17. Handle release pedal
18. ON/OFF pedal
19. Hose
20. Cord hooks (tool caddy stored on
cleaner)
21. Hose connector
22. Tool caddy
Your HOOVER Deep Cleaner is
fully assembled and ready to begin cleaning!
This deep cleaner is intended for household use.
Operate deep cleaner only at voltage specified on data plate on back of cleaner. Plug deep cleaner into a
properly grounded outlet.
Unfold handle How to fold handle
Raise upper handle (A) to upright position until it locks in place.
Press upper handle release
button (B) to fold handle.
Fill the solution tank
Unplug deep cleaner from
electrical outlet.
/
Press button (A) and remove solution tank (Fig. 3)
/
Release latches (B) on tank cap and remove (Fig. 4)
/
Use cap on solution tank (Fig. 5) to mea- sure the proper amount of HOOVER detergent according to the chart below:
Amount of
Surface detergent Type of detergent
Carpet two HOOVER Carpet/
caps Upholstery Detergent
Upholstery one HOOVER Carpet/
cap Upholstery Detergent
For heavy traffic areas: Pre-treat with HOOVER Spot and Stain Spray (available at additional cost if not
included with your model)
OR
Use 4 caps of Carpet/Upholstery detergent.
They are specifically formulated for use with your NOTE: For best results, use only Hoover detergents.
SteamVaC M Deep Cleaner.
/
Pour detergent into tank
/
Fill tank to fill line (C) (approx. 1 gallon) with hot tap water
(Fig.6)
/
Replace cap. Secure both latches (B) (Fig. 4)
/
Place bottom of tank onto cleaner. Pivot top of tank and snap in place (Fig. 7)
)
TWiCe_o_¢A_Pe_
0_C_ f_rUP_0LST_a¥
CLEANING D_TERGEN'/
TO ASSURE pFJ_
pERFORMANCE
FJ_IT_kw_th
HOT TAP WMER
USEO_L¥HOOW_
Caution: Detergents contain Anionic and Nonionic Surfactants. Avoid contact with the eyes and skin. In case of contact with eyes, flush with cold water for 15 minutes.
In case of contact with skin, wash with water. If irritation persists, call a physician. For Medical Information (U.S.),
call 1-800-752-7869.