Hoover F5906900 User Manual

The Easy to Use Deep Cleaner
with attached tools
Review this manual before operating deep cleaner
Owner’s Manual
ENGLISH pp. 1-15 ESPAÑOL pág. 16-25 FRANÇAIS p. 26-35
®
SteamVac™ Deep Cleaner cleans carpet fibers by applying hot tap water and cleaning solution.
www.hoover.com
2
Important Safeguards!
When using an electrical appliance, always follow basic
precautions, including the following:
WARNING:
To reduce the risk of fire, electric shock, or injury:
• Use indoors only.
• Use only on surfaces moistened by the cleaning process or small spills. Do not immerse product.
• Connect to a properly grounded outlet only. See “Grounding Instructions”.
• Do not clean over floor electrical outlets.
• Do not use without tanks in place.
• Use extra care when cleaning on stairs. Do not place deep cleaner on stairs.
• Use deep cleaner only for its intended use as described in the instructions.
• Use only attachments recommend­ed by The Hoover Company; others may cause hazards.
• The use of an extension cord is not recommended. If an extension cord is
absolutely necessary, use at least a 16 gauge 3-wire cord which has a 3­prong grounding type plug and a 3­pole receptacle that accepts the machine plug.
• Unplug deep cleaner when not in use. Turn off all controls before unplugging.
• Unplug before connecting the pow­ered hand tool.
• Always disconnect cord from electri­cal outlet before servicing the deep cleaner.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
• Never handle plug or appliance with wet hands.
• Do not pull or carry by cord, use cord as a handle, close door on cord or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
Grounding
Instructions
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resis­tance for electrical current to reduce the risk of electric shock. This appliance is equipped with a cord having an equip­ment-grounding conductor (C) and grounding plug (A). The plug must be plugged into an appropriate outlet (B) that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER-
Improper connection of the equipment­grounding conductor can result in the risk of electric shock. Check with a qual­ified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug (A) illustrated in sketch (Fig. 1).
A temporary adapter (D) may be used to connect this plug to a 2-pole receptacle (E) if a properly grounded outlet is not available (Fig. 2). The temporary adapter should be used only until a properly grounded outlet (B) can be installed by a qualified electrician (Fig. 1). The green colored rigid ear, lug, or the like (F) extending from the adapter must be con­nected to a permanent ground (G) such as a properly grounded outlet box cover (Fig. 2). Whenever the adapter is used, it must be held in place by a metal screw. NOTE: In Canada, the use of a tempo­rary adapter is not permitted by the Canadian Electrical Code.
A
B
C
Fig. 1
Fig. 2
D
F
G
E
READ ALL INSTRUCTIONS BEFORE USING APPLIANCE.
• Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, take it to a Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer.
• Close supervision is necessary when any appliance is used by or near children. Do not allow deep cleaner to be used as a toy or to run unattended at any time.
• Do not point tools toward people or pets.
• Use only commercially available floor cleaners intended for machine application. Do not use any type of wax with deep cleaner.
• To assist in reducing drying time, be certain the area is well ventilated when using detergents and other cleaners with this machine.
• Keep detergents and other cleaners out of children's reach.
• Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
• Do not pick up chlorine bleach, drain cleaner, gasoline or any other toxic material with this appliance.
• Do not pick up anything that is burning or smoking, such as ciga­rettes, matches, or hot ashes.
• Avoid picking up hard, sharp objects with the deep cleaner. They may damage the machine.
• Keep hair, loose clothing, fingers, feet and all parts of body away from openings and moving parts.
• Do not put any object into open­ings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
• To help prevent matting and resoil­ing, avoid contact with carpets until they are dry. Keep children and pets away from carpets until they are com­pletely dry.
• Store in a dry place. Do not expose machine to freezing temperatures.
Save these instructions!
3
Fill in and Save
Please enter the COMPLETE model and serial numbers in the spaces provided and save.
The model and serial numbers are located on the data label on the back of the handle.
Model No.____________________________ Serial number_________________________
Hint: Attach your sales receipt to this owner s manual. Verification of date of purchase may be required for warranty service of your
Hoover product.
Contents
Important safeguards . . . . . . . . . . 2
Parts needed for assembly. . . . . . . 3
Assembling deep cleaner . . . . . . 3-5
Deep cleaner description . . . . . . . . 6
General operation . . . . . . . . . . . . 6-9
Filling the clean solution tank . 7-8 Emptying the recovery tank . . 8-9
Brush speed selector . . . . . . . . . 7
Brush Indicator . . . . . . . . . . . . . . 7
How to use
Before you begin . . . . . . . . . . . . 9
After cleaning . . . . . . . . . . . . 9-10
Cleaning carpet . . . . . . . . . . . . 10
Picking up spills . . . . . . . . . . . . 10
Cleaning bare floors . . . . . . 10-11
Using the tools . . . . . . . . . . 11-14
Cleaning carpeted stairs. . . . . 13
Cleaning upholstery . . . . . 13-14
If you have a problem . . . . . . . . . 15
Lubrication . . . . . . . . . . . . . . . . . . 15
Service . . . . . . . . . . . . . . . . . . . . . 15
Storage . . . . . . . . . . . . . . . . . . . . . 15
Warranty . . . . . . . . . . . . . . . . . . . . 15
1. Assembly
A
B
C
H
E
1-1
A. Deep cleaner B. Upper handle C. Handle bolts and nuts D. Tool holder with screw E. Hose F. Hose holder G. Stair/upholstery nozzle
H. Deep Cleansing Detergent
© 2004 The Hoover Company
www.hoover .com
Carton contents
Thank you for choosing a HOOVER product.
If you need any assistance:
Visit our website at www.hoover.com. Click on the “Service” button to find the service outlet nearest you OR Call 1-800-944-9200 for an automated referral of service outlet locations (U.S. only) OR Call 1-330-499-9499 to speak with a representative in our Consumer Response Center.
PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE.
Accessories
F
Additional accessories not included with your model may be purchased separately using the order form located at the center of this manual.
D
G
Carpet
Bare
Upholstery
floor
Cleaner
cleaner
Attach hose holder
Position hose holder (B) onto handle by matching tabs on rack with openings on back of handle. Make sure bolts are through holes.
4
The assembled cleaner will look like this drawing.
1-2
Attach upper handle
Remove clean solution tank (upper tank) from deep cleaner.
With cord hook (A) to back of deep cleaner, push upper handle down onto lower han­dle. Push bolts into holes on front of han-
dle. If bolts will not go through hole easi­ly handle is not pushed completely down.
1-3
1-6
1-9
1-4
1-5
1-7
1-8
When handle sections are completely together, squeeze trigger (C) on upper handle to snap trigger rod in place.
A
C
B
Replace clean solution tank (upper tank) by positioning bottom first. Press on tank handle to snap top of tank into place.
Place nuts in recessed areas on back of hose holder. Hold each nut in place while tightening each bolt securely (from the front of the handle) with a Phillips screwdriver. Only two nuts are needed on this model. The extra nut is not required but has been provided for your conve­nience.
Attach tool holder
Remove tool and taped screw from holder. Insert projections on holder into slots on back of cleaner.
Slide holder down into place. Insert screw at (D) and tighten with a Phillips screwdriver.
D
5
1-14
1-10
1-11
Press cord into cord clip on back of hose holder. Pull cord tight.
Storing hose
Stretch hose out and identify ends.
E. Nozzle connector end of hose G. Solution tube F. Trigger H. Converter end of hose Note: You may find it helpful when storing the hose to refer to the information on the back of the deep cleaner and on the converter end of the hose.
Start with converter end of hose (H). Fit converter over tab near tool holder (I). Press converter firmly to snap in place. Press solution tube (G) into clip next to converter as shown.
Wrap hose around hook on upper handle (J). Press hose into clips on upper hose holder (K).
G
H
H
I
J
K
G
K
F
E
1-12 1-13
Wrap hose around lower tool holder and continue until nozzle connector is near upper hose holder. Clip hose in place.
Continued
How to reattach tool cover
The tool cover is designed with a break­away feature which allows it to snap free if it is pushed open too far.
To reattach, align hinges of cover with slots on sides of tool storage area.
Push cover down to secure in place.
1-15
1-16
Stair/upholstery nozzle
To store stair/upholstery nozzle, open tool door, place nozzle in bracket and fit it securely into position. To remove,
reverse this procedure.
Upfront tool storage
6
1. Hand grip
2. Solution trigger: press to
release clean solution.
3. Cord clip: place cord in clip
to keep it out of the way when using cleaner
4. Hose
5. Hose holder: wrap hose
around holder and hooks for storage.
6. Hose hooks
7. Cord hooks: wrap cord
around hooks for storage. The top hook can be rotated right or left for quick and easy cord release.
8. Stair/upholstery nozzle
9. Carrying handle
10. Clean solution tank handle
11. Clean solution tank cap/ measuring cup
12. Clean solution tank: holds
cleaning solution.
13. Recovery tank lid
14. Recovery tank: holds dirty
solution.
15. Recovery tank front panel
2. How to use
The assembled deep cleaner will look like the drawing.
2-1
2-2
16. Hood
17. Brush speed selector:
slide selector to set brush speed on HI, LO, or OFF.
18. Brush Indicator: spins
when brushes are rotating.
19. Nozzle
20. Solution tube connection
21. Recovery tank latches
22. ON/OFF pedal
23. Handle release pedal: step
on pedal to lower handle to operating (floor) position.
This deep cleaner is intended for household use.
Operate deep cleaner only at voltage specified on data plate on back of cleaner. Plug deep cleaner Into a properly ground­ed outlet.
ON/OFF pedal & Handle release pedal
Step on pedal (A) to turn deep cleaner on. Step on pedal again to turn deep cleaner off.
Step on pedal (B) to lower handle to operating position. Handle does not lock into a single position but “floats” to allow convenient operation.
A
B
To transport
To move your deep cleaner from room to room put handle in upright and locked position tilt deep cleaner back on wheels and push forward.
2-3
The deep cleaner may also be lifted by placing a hand under the upper clean solution tank handle as shown.
1
2
3
4
7
6
6
5
4
7
8
9
10
11
12
13
14
15
16
17
18
19
20
22
21
23
Deep cleaner description
2-4
7
Agitator Speed
OFF
HI
LO
2-5
2-6
2-7
Automatic “shut off”
When the recovery tank (lower tank) is full the automatic shutoff mechanism will shut off the deep cleaner suction (suction will
be noticeably reduced).
At that time the yellow float disk will rise to the top of the recovery tank lid (E). The deep cleaner will no longer pick up dirty solution and the motor sound will
become noticeably higher in pitch. When this happens turn deep cleaner
off and empty recovery tank before
continuing use. Check clean solution tank also; it may
need to be refilled.
E
F
G
Brush speed selector
Your ‘SteamVac’ deep cleaner has three agitator brush settings.
Hl - for normal cleaning of carpet and bare floors
LO - for gentle cleaning of carpets and bare floors
OFF - for cleaning carpets and bare floors when brushing is not desired. (Such as when picking up liquid spills. See page 10.)
Slide selector button to the desired set­ting before cleaning.
Brush indicator
The brush indicator will spin (F) when the deep cleaner is turned ON and the brushes are rotating.
If the indicator does not spin and the pattern is visible (G)
when the deep
cleaner is turned ON,
the brushes are
not rotating.
There are three reasons why the brushes may not be rotating:
1. Brush speed selector set on OFF (see previous section).
2. Handle in upright position.
3. Brush indicator screen dirty.
2-10
Rotate tank cap counterclockwise and lift up to remove cap.
2-8
2-9
H
To clean screen (H), turn deep cleaner off and disconnect from electrical outlet.
Remove clear cover and wipe off screen with a damp cloth. Snap cover back into position.
The tanks
Clean solution tank (upper tank)
The clean solution tank holds the clean­ing solution that is to be dispersed onto the surface to be cleaned.
How to fill
Disconnect deep cleaner from electrical outlet.
Place deep cleaner handle in the upright, locked position.
To remove tank, press down on handle and pull forward.
Carry tank to a sink.
2-11
Turn cap (A) upside down to serve as a measuring cup.
5 OUNCES/ 150 ml
A
D
C
2-12
2-13
2-14
2-15
Using cap, measure detergent following the chart below.
For carpet, carpeted stairs and uphol­stery:
Fill cap to fill line (5 ounces) with HOOVER Deep Cleansing™ Detergent.
For bare floors: Fill cap to fill line (5 ounces) with HOOVER
Bare Floor Cleaner *
Do not use Bare Floor Cleaner on carpet or upholstery. Do not use any type of wax
with your ‘SteamVac’deep cleaner. NOTE: Use only HOOVER detergents.
They are specially formulated for use with your ‘SteamVac’ deep cleaner.
*Available at additional cost if not included with your model.
CAUTION: Detergents contain Anionic and Nonionic Surfactants. Avoid contact with eyes and skin. In case of contact with eyes, flush with cold water for 15 minutes. In case of contact with skin, wash with water. If Irritation persists, call a physician. For Medical Information (U.S.) call 1-800-752-7869.
Pour detergent into tank. Fill tank to fill line (B) (1 gallon) with hot tap water.
To assure proper performance, use only HOOVER cleaning detergent.
B
If rubber ring (C) on cap has become dislodged, reposition it with uneven side against ledge (D) as shown.
Replace cap. Rotate cap clockwise
until it locks in place. Cap must be locked in place for proper perfor­mance and to prevent leaking.
Position bottom of tank into unit and press on tank handle to snap tank into place.
Recovery tank
(lower tank)
The recovery tank holds the dirty solu­tion that is picked up from the carpet.
When the recovery tank is full, the auto­matic shut-off will engage (see page 7) and the tank must be emptied.
How to empty
Turn deep cleaner off and disconnect from electrical outlet.
To prevent possible leaking, remove clean solution tank (Fig. 2-9) by pressing down on tank handle and pulling for­ward; set tank aside (do not set tank
on furniture).
For heavy traffic areas: Pre-treat with HOOVER Spot and
Stain Spray Cleaner. If you do not have access to the Spot
and Stain Spray Cleaner, double the amount of HOOVER Deep Cleansing™ Detergent (use 2 capfuls or 10 ounces per 1 gallon tank).
8
9
2-16
2-19
2-17
2-18
Step on handle release pedal and lower handle until it rests on the floor.
If cleaning stairs or upholstery, remove hose by reversing procedure as shown on pages 11 and 12.
Rotate recovery tank latches (E) outward (one on each side of tank).
Lift tank off of deep cleaner and carry it to a sink or drain.
Unlatch back part of tank lid and remove lid.
Empty tank. Pour dirty water out from the rear of the tank (F).
The lid replaces in a hinge-like man­ner. Position the front of lid under tabs
(G) on front of tank. Rotate lid down onto tank. Make sure that the lid is
secure on all sides
before placing
tank on cleaner.
For full suction, it is important that the recovery tank lid is prop­erly secured before cleaning.
Replace tank and press down to ensure that it is properly seated in place.
Rotate latches (E) (one on each side of tank) inward to lock tank in place.
To continue cleaning stairs or upholstery, replace hose as shown on pages 11 and
12. Raise handle to upright position and replace upper clean solution tank.
3. How to clean
Before you begin cleaning
a. Vacuum thoroughly - For carpet, use a vacuum cleaner with an agitator for best results. Vacuum upholstery with a vacuum cleaner with cleaning tool attachments. Use a crevice tool to reach into tufts and folds. Do not use the
‘SteamVac’deep cleaner as a dry vac­uum cleaner.
b. For upholstery, check cleaning code - Use your HOOVER ‘SteamVac’
deep cleaner only if the upholstery fab­ric is marked with a “W” (for “wet” clean) or “S/W” (for “solvent/dry” or “wet” clean). Do not clean fabric marked “S” (“solvent/dry” clean only). If your upholstery does not have a code, seek professional assistance.
c. T est for colorfastness - Mix detergent and water according to the instructions under “Fill clean solution tank” on pages 7
and 8. Wet a white absorbent cloth with the solution. In a small, hidden area, gently rub the surface with the dampened cloth. Wait ten minutes and check for color removal or bleed with white paper towel or cloth. If surface has more than one color, check all colors.
d. When cleaning entire floor, move furniture out of area to be cleaned
(may not be necessary if only high traffic areas are to be cleaned). For furniture too heavy to move, place aluminum foil or wax paper under legs. This will pre­vent wood finishes from staining carpet. Pin up furniture skirts and draperies.
e. Pretreat spots and heavy traffic areas with HOOVER
® Spot and Stain
Spray Cleaner*- Test Spot and Stain
Spray Cleaner for colorfastness by first spraying it on a hidden area; wait ten minutes and blot with white paper towels or cloth. If no color change is visible, spray Spot and Stain Spray Cleaner onto spots and traffic areas. Wait at least ten minutes. Use your ‘SteamVac’ deep cleaner to pick up Spot and Stain Spray Cleaner and spot. Repeat until spot is removed; carefully scrub with a
household scrub brush if necessary. Do not saturate carpet or upholstery with
Spot and Stain Spray Cleaner.
If you do not have access to the Spot and Stain Spray Cleaner, double the amount of HOOVER Deep Cleansing™ Detergent (use 2 capfuls or 10 oz. per 1 gallon) in the clean solution tank.
No cleaning solution removes all stains from all carpets. Stain removal varies with the type of spill, time elapsed before removal, carpet material, and carpet type.
f. T o prevent staining, use plastic or alu­minum foil to protect wood or metal sur­faces from possible water spray.
g. T o avoid wetting and possible damage to wood floors underneath area rugs/car­pet, either
move area rugs/ carpet to a non-
E
F
G
E
wood bare floor surface or place waterproof material (e.g. plastic) underneath them before cleaning.
See pages 10 and 11 for instructions on various cleaning tasks.
*Available at additional cost if not included with your model.
After cleaning
a. Allow carpet or upholstery to dry. To help prevent matting and resoiling the carpet, keep children and pets away from surface until it is completely dry. If it is necessary to walk on damp car­pet, place towels or white cloths on the traffic areas.
If furniture must be replaced before the carpet is dry, use plastic or aluminum foil pads under legs of furniture so metal slides or wood finishes will not stain the carpet.
b. If desired, the carpet may be rinsed. Rinsing is not necessary for cleaning,
but it may improve the surface’s appear­ance after it is dry.
To clean the outside of the machine, wipe off dirt with a cloth dampened in warm water and mild detergent. Do not
use solvent or petroleum based prod­ucts to clean the machine.
Carpet Cleaning
Picking up spills
Read “Before you begin cleaning” instructions on page 9.
1. Fill clean solution tank (upper tank) with HOOVER Deep Cleansing™ Detergent according to instructions on pages 7 and 8.
3-2
2. Move speed selector to LO for gen­tle cleaning or Hl for normal cleaning.
3. Dry hands and plug cord into a prop­erly grounded outlet.
Do not clean over floor electrical out­lets.
4. To avoid walking on damp carpet, start at the end of the room farthest from the door or path to sink where tanks will be emptied and filled.
Step on handle release pedal and lower handle to operating position; turn deep cleaner ON.
5. Squeeze trigger to release cleaning solution and slowly push deep cleaner forward (equals one wet stroke).
6. Continue to squeeze trigger and slow- ly pull deep cleaner back toward you (second wet stroke). Release trigger and slowly push deep cleaner forward over area just sprayed with solution (dry stroke). Then slowly pull deep cleaner back toward you without squeezing trig­ger (dry stroke).
7. Overlap strokes by 1 inch to help pre­vent streaking. Keep nozzle flat on floor for both forward and reverse strokes.
8. For heavily soiled areas, repeat steps 5-7.
Note: To avoid saturating carpet, do not use more than 4 wet strokes over one area. Always end with dry strokes.
It is best to alternate wet and dry strokes as described above.
For best cleaning results and to aid in faster drying of carpet, end with more dry strokes. (Continue using dry strokes until little water is visible passing through the recovery tank lid.) Empty recovery tank when the motor sound becomes higher pitched and there is a loss in suction (see “Automatic shut-off”, page 7).
When finished cleaning, follow “After cleaning” instructions on pages 9 and
10.
Your HOOVER SteamVac deep cleaner may also be used to pick up small liq-
uid spills (1 gallon or less, never to exceed 1/4 inch in depth) on carpet,
upholstery, or bare floors. For best results, pick up spills immedi-
ately by placing the stair/upholstery noz­zle just above the spill and suction up any residue on top of the carpet. If the spill remains, place either the stair/ upholstery nozzle or floor nozzle
with
brushes turned OFF in
front of the spill, pull the nozzle very slowly over the spill initially with suction only. Repeat with spray and suction.
When picking up spills on bare floors, use only the floor nozzle with the bare floor attachment in place and speed selector in the OFF position (this will help
prevent spreading the spill). If a spot is left, the stair/upholstery nozzle is
generally more effective for removing it. Although no cleaning solution can com­pletely remove all spots, they can be treat­ed by following the instructions provided by the manufacturer of the carpet, upholstery, or bare floor surface being cleaned.
Do not use the SteamVac deep cleaner to pick up flammable or combustible liq­uids or chemicals.
When finished, follow “After cleaning” instructions on pages 9 and 10.
10
3-1
If rinsing is desired, be careful not to over-wet the carpet or upholstery.
Allow time for carpet or upholstery to dry completely between cleaning and rinsing. To rinse, follow the same proce-
dure for cleaning only using hot tap water with no detergent in the upper clean solution tank.
c. Empty tanks, rinse with clear water and let air dry. Rinse the solution tank cap and recovery tank lid and let air dry.
To clean nozzle
If lint or other debris becomes lodged in
nozzle, do not attempt to remove nozzle cover.
Pour one to two cups of clear water on a non-carpeted floor. Do not pour water
onto a wood floor.
Pick up water with your ‘SteamVac’ deep cleaner. Repeat as necessary until debris is flushed out of nozzle.
d. Remove debris from recovery tank fil­ter and rinse with clean water.
Note: If the filter must be removed for cleaning, it is easier to replace if the fil­ter is wet.
e. If desired, vacuum thoroughly after carpet has completely dried. This will help reduce any shading left by the deep cleaner’s brushes.
Cleaning bare floors
How to attach bare floor attachment (available at addi-
tional cost)
Disconnect deep cleaner from electri­cal outlet.
To prevent possible leaking, remove clean solution tank and recovery tank before positioning bare attachment. Refer to Fig. 2-9 to remove clean solu­tion tank. Set tank aside (do not set tank on furniture).
Refer to Fig. 2-16 to remove recovery tank.
With handle in upright position, tilt clean­er back so that handle rests on the floor.
R
O
T
A
T
E
O
N
B
A
R
E
F
L
O
O
R
3-3
With foam strip (A) (located under the netting) in position as shown, place attachment on front of nozzle (B). Make sure arrow on end of attachment points in the direction as shown.
A
B
R
O
T
A
B
A
T
R
E
E
F
L
O
O
O
N
R
11
To release solution, press trigger. Slowly move deep cleaner forward and back­ward over area to be cleaned.
To pick up dirty solution, release trigger and slowly move deep cleaner over area where solution has just been dis­persed. Use both forward and reverse strokes.
Empty recovery tank when the motor sound becomes higher pitched and there is a loss in suction (see “Automatic shut-off”, page 7).
When finished cleaning, follow “After cleaning” instructions on pages 9 and
10. Remove attachment from nozzle and
rinse in clear water. Do not remove
plastic screen or foam from attach­ment.
To clean floor
Read Before you begin cleaning instructions on page 10.
Do not use the SteamVac deep clean­er on hardwood floors.
Fill clean solution tank with HOOVER Bare Floor Cleaner (available at additional cost if not included with your model) according to instructions on pages 7 and 8.
Do not use any type of wax with your SteamVac deep cleaner.
Move speed selector to the Lo or Hl position for scrubbing or OFF if scrubbing is not desired.
Dry hands and plug deep cleaner into a properly grounded outlet.
Step on handle release pedal and lower handle to operating position; turn deep cleaner ON.
R
O
T
A
T
E
O
N
B
A
R
E
F
L
O
O
R
3-4
Push attachment against nozzle while rotat­ing attachment downward until both ends snap into place.
(Note: Some force may be required to rotate and snap attachment into place.)
Return deep cleaner to upright position. Lower handle and replace recovery tank.
Raise handle to upright position and reposition clean solution tank.
Using the tool
Stair/upholstery nozzle has a built-in brush to help provide the scrubbing action some spots may need for removal.
3-5
3-6
3-7
D
E
How to attach hose
Disconnect deep cleaner from electri­cal outlet.
1. To prevent possible leaking, remove clean solution tank by pressing down on tank handle (D) and pulling forward; set tank aside (do not set tank on furniture). Remove hose from storage rack.
2. Step on handle release pedal (E) and lower deep cleaner handle until it rests on the floor. Unlatch back part of recovery tank and remove lid.
Loading...
+ 25 hidden pages