Hoover F5857955 Owner's Manual

Page 1
HOOVER ®
© 1995, 1996 The Hoover Company
The Easy to Use Deep
Cleaner
attached tools
®
Thank you for selecting a HOOVER product.
This cleaner was inspected and packaged carefully before being shipped from the factory. If you should happen to need assistance during assembly or operation, call
1-800-944-9200 for an automated referral of authorized service outlet locations (U.S. only) or 1-330-499-9499 (U.S.) and 1-800-263-6376 (Canada) to speak with a Hoover representative.with
DO NOT RETURN THIS PRODUCT
TO THE STORE.
Owner’s Manual
Review this manual before oper­ating deep cleaner.
Record and Retain
This HOOVER deep cleaner is designed for deep cleaning of carpet, and rugs. It can also be used to clean carpeted stairs and upholstery.
The model and serial numbers are located on the data label on the back of the deep cleaner handle.
For your personal records, please enter the COMPLETE model and serial numbers in the spaces provided and retain this information.
Your deep cleaner is model and has serial number
It is suggested that you attach your sales receipt to this owner’s manual. Verification of date of purchase may be required for warranty service of your Hoover product.
Grounding Instructions
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electrical current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment­grounding conductor and grounding plug (A). The plug must be plugged into an appropriate outlet (B) that is properly installed and grounded in accordance with all local codes and ordinances.
(A)
GROUNDING PIN
(B)
DANGER-
Improper connection of the equipment-grounding conductor can result in the risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in sketch (A).
Index
Important safeguards .....................................................2
Unpacking deep cleaner.................................................2
Assembling deep cleaner........................................... 3-5
Deep cleaner description ...............................................5
General operation ...........................................................6
Filling the clean solution tank ............................ 7-8
Emptying the recovery tank....................................8
Agitator speed selector...........................................6
Brush indicator ........................................................7
How to use
Before you begin......................................................9
After cleaning ...........................................................9
Cleaning carpet ......................................................10
Picking up spills.....................................................10
Cleaning bare floors ........................................ 10-11
Using the stair/upholstery nozzle................... 11-12
Cleaning carpeted stairs................................13
Cleaning upholstery .......................................14
If you have a problem ...................................................15
Lubrication.....................................................................14
Service ..........................................................................15
Storage ..........................................................................14
A temporary adapter (C) may be used to connect this plug to a 2-pole receptacle (D) if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet (B) can be installed by a qualified electrician. The green colored rigid ear, lug, or the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. When­ever the adapter is used, it must be held in place by a metal screw.
(C)
NOTE: In Canada, the use of a temporary adaptor is not
permitted by the Canadian Electrical Code.
TAB FOR GROUNDING SCREW
METAL SCREW
(D)
Page 2
WARNING:
To reduce the risk of fire, electric shock, or injury:
When using an electrical appliance, always follow
basic precautions, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
Important Safeguards!
Questions or Concerns?
• Use indoors only.
• Use only on surfaces moistened by the cleaning process or small spills. Do not immerse product.
• Connect to a properly grounded outlet only. See “Grounding Instruc­tions”.
• Do not clean over floor electrical outlets.
• Do not use without tanks in place.
• Use extra care when cleaning on stairs. Do not place deep cleaner on stairs.
• Use deep cleaner only for its intended use as described in the instruc­tions. Use only attachments recommended by The Hoover Company; others may cause hazards.
• The use of an extension cord is not recommended. If an extension cord is absolutely necessary, use at least a 16 gauge 3-wire cord which has a 3-prong grounding type plug and a 3-pole receptacle that accepts the machine plug.
• Unplug deep cleaner when not in use. Turn off all controls before unplugging.
• Always disconnect cord from electrical outlet before servicing the deep cleaner.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. Never handle plug or appliance with wet hands.
• Do not pull or carry by cord, use cord as a handle, close door on cord or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
• Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, take it to a Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer.
• Close supervision is necessary when any appliance is used by or near children. Do not allow deep cleaner to be used as a toy or to run unattended at any time.
• Do not point stair/upholstery tool toward people or pets.
• Use only commercially available floor cleaners intended for machine application. Do not use any type of wax with deep cleaner.
• To assist in reducing drying time, be certain the area is well ventilated when using detergents and other cleaners with this machine.
• Keep detergents and other cleaners out of children’s reach.
• Do not use to pick up flammable or combustible liquids such as gaso­line or use in areas where they may be present.
• Do not pick up chlorine bleach, drain cleaner, gasoline or any other toxic material with this appliance.
• Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
• Avoid picking up hard, sharp objects with the deep cleaner. They may damage the machine.
• Keep hair, loose clothing, fingers, feet and all parts of body away from openings and moving parts. Do not operate deep cleaner in bare feet or when wearing open toe shoes or sandals.
• Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
• To help prevent matting and resoiling, avoid contact with carpets until they are dry. Keep children and pets away from carpets until they are completely dry.
• Store in a dry place. Do not expose machine to freezing temperatures.
The Hoover Company wants to quickly resolve any concerns about your cleaner or questions regard­ing its use. Look on the list provided with the product for your local Hoover Factory Service Center or in the Yellow Pages under “Vacuum Cleaners - Household” for the nearest Authorized
Hoover Warranty Service Dealer (Depot) or call:
1-800-944-9200 for an automated referral
of authorized service outlet locations (U.S. only) or
1-330-499-9499 (U.S.) and 1-800-263-6376
(Canada) to speak with a Hoover representative.
DO NOT RETURN THIS PRODUCT TO THE STORE OR SEND IT TO NORTH CANTON FOR SERVICE.
Unpack deep cleaner from the carton and identify the parts shown. Remove and dispose of the cardboard packing and tape securing rotating brushes for shipping purposes only.
Unpacking
Save these instructions!
J
A
A. Deep cleaner B. Upper handle with hose/nozzle rack C. Bolts (2) D. Nuts (3 - one extra included) E. Carpet/Upholstery Detergent (some models
come with 2 bottles)
F. Bare Floor Cleaner (some models come with
2 bottles)
G. PreCleaner (included with some models) H. Bare floor attachment I. Hose J. Stair/upholstery nozzle K. Lower hose hook and screw L. Nozzle clean-out tool
C D
I
B
L
G
E
F
K
H
Page 3
Continued
5
Assembling deep cleaner
The assembled cleaner will look like this drawing.
4
Push bolts into holes on front of handle (Fig. 4). If bolts will not go through hole easily handle is not pushed completely down.
Attach upper handle
1
Remove clean solution tank (upper tank) (Fig. 1).
2
Remove nozzle stored on upper handle by gently pushing nozzle downward while pivoting it away from the handle at (B).
3
CORD HOOK
(B)
Place nuts in recessed areas on back of handle. Hold each nut in place while tightening each bolt securely with a Phillips screw driver (Fig. 5).
Only two nuts are needed on this model. The extra nut is not required but has been provided for your convenience.
6
SQUEEZE TRIGGER
When handle sections are completely together, squeeze trigger on upper handle to snap trigger rod in place (Fig. 6).
7
TANK HANDLE
With cord hook to back of deep cleaner, push upper handle down onto lower handle. (Fig.3).
Replace clean solution tank (upper tank) by positioning bottom first. Press on tank handle to snap top of tank into place (Fig. 7).
Page 4
8
12
HANDLE
NOZZLE CONNECTOR
Press cord into cord clip on back of handle. Pull cord tightn (Fig. 8).
Attach lower hose holder
9
PROJECTIONS
With front of deep cleaner resting on floor, place 2 projections on lower hose holder into 2 holes on back of cleaner (Fig 9).
HOSE HOLDER
HOLES
CORD HOOK
To store hose on rack, begin by placing nozzle connector end of hose (straight end) into clip 1 on rack (Fig. 12).
13
4
CLIP 1
CLIP 1
2
2
1
2
10
Push screw into hole and tighten securely with a Phillips screw driver (Fig 10).
Storing hose and nozzle on rack
11
Stretch hose out and identify ends. Note: You may find it helpful when storing the hose and nozzle to refer to the information on the back of the deep cleaner
and on the converter end of the hose (Fig. 11).
NOZZLE CONNECTOR END OF HOSE
TRIGGER
SOLUTION
HOSE CONVERTER END OF HOSE
3
Secure hose to rack at numbered locations as shown. (Fig. 13)
14
EXTENSION
HOOK
Converter is stored in area as shown.
While aligning arrows (Fig. 14), place extension into bottom of converter opening; then push converter firmly against deep cleaner until it snaps into place.
To remove, first pull top of converter off extension then pull off bottom.
Secure solution hose to converter as shown.
Page 5
Deep cleaner description
1. Hand grip
2. Solution trigger: press to release clean solution.
3. Hose
4. Hose holders: wrap hose around holders for storage.
5. Cord hooks: wrap cord around hooks for storage.
The top hook can be rotated right or left for quick and easy cord release.
6. Stair/upholstery nozzle
7. Carrying handle
8. Clean solution tank handle
9. Clean solution tank cap/ measuring cup
10. Clean solution tank: holds cleaning solution.
11. Recovery tank lid
12. Recovery tank: holds dirty solution.
13. Recovery tank “front panel”
14. Hood
15. Agitator speed selector: slide selector to set brush
speed on HI, LO, or OFF.
16. Brush indicator: spins when brushes are rotating.
17. Nozzle
18. Upholstery and stair cleaning connection: push door
open to connect stair/upholstery tool “solution tube”.
19. Recovery tank latches: one on each side of tank.
20. ON/OFF pedal
21. Handle release pedal: step on pedal to lower handle
to operating position.
The assembled deep cleaner will look like the drawing below.
15
(B)
TAB (A)
The nozzle is stored in the area between the cord hooks (Fig. 15).
Place brushes of nozzle on top of Tab (A) as shown. Gently push the nozzle downward while pivoting it into the nozzle holder (B).
19
18
2
1
3
4
5
6
7
8
9
5
10
11
12
13
14
4
15
16
17
20
21
19
This deep cleaner is intended for household use.
Page 6
General operation
ON/OFF PEDAL
Operate deep cleaner only at voltage specified on data plate on back of cleaner.
ON/OFF pedal
Plug deep cleaner into a properly grounded outlet.
Step on pedal to turn deep cleaner on. Step on pedal again to turn deep cleaner off.
Handle release pedal
To transport
Turn deep cleaner off before transporting.
To move your deep cleaner from room to room, put handle in upright and locked position, tilt deep cleaner back on wheels, and push forward.
HANDLE RELEASE PEDAL
Step on pedal to lower handle to operating position. Handle does not lock into a single position but “floats” to allow conve­nient operation.
Automatic “shut-off”
FLOAT DISK
When the recovery tank (lower tank) is full, the automatic “shut­off”mechanism will shut off the deep cleaner suction.
At that time, the red float disk will rise to the top of the recovery tank lid (see illustration). The deep cleaner will no longer pick up dirty solution and the motor sound will become noticeably higher in pitch.
When this happens, turn deep cleaner off and empty recovery tank before continuing use.
The deep cleaner may also be lifted by placing a hand under the upper clean solution tank handle as shown.
Agitator speed selector
Your ‘SteamVac’ deep cleaner has three agitator brush settings.
HI - for normal cleaning of carpet and bare floors LO - for gentle cleaning of carpets and bare floors OFF - for cleaning carpets and bare floors when
brushing is not desired. (Such as when picking up liquid spills. See page 10.)
Slide selector button to the desired setting before cleaning.
NOTE: Check the recovery tank often. Empty tank when it appears full even if the automatic shut-off has not engaged.
Check clean solution tank also; it may need to be refilled.
Page 7
Turn cap upside down to serve as a measuring cup.
Fill cap to upper “carpet” fill line (5 ounces) with HOOVER
Carpet/Upholstery Detergent.
For bare floors:
Fill cap to upper "carpet” fill line (5 ounces) with HOOVER Bare Floor Cleaner
TANK CAP
Brush indicator
5 OUNCES (carpet)
3 OUNCES (upholstery)
The brush indicator will spin when the deep cleaner is turned on and the brushes are rotating.
There are three reasons why the brushes may not be rotating:
1. Brush speed selector set on OFF. (See previous section.)
2. Solution tube connected (page 12).
3. Brush indicator screen dirty. To clean screen, turn deep cleaner off and disconnect from
electrical outlet.
SCREEN
Remove clear cover and wipe off screen with a damp cloth. Snap cover back into position.
If the indicator does not spin and the pattern is visible
when the deep cleaner is turned on, the brushes are
not rotating.
The tanks
Clean solution tank (upper tank)
The clean solution tank holds the cleaning solution that is to be dispersed onto the surface to be cleaned.
How to fill
Disconnect deep cleaner from electrical outlet.
Using cap, measure detergent following the chart below.
For carpet and carpeted stairs:
Do not use any type of wax with your ‘SteamVac’ deep cleaner.
Do not use Bare Floor Cleaner on carpet or upholstery.
For upholstery:
Fill cap to lower “upholstery” fill line (3 ounces) with HOOVER Carpet/Upholstery Detergent.
NOTE: Use only HOOVER detergents. They are specially formulated for use with your 'SteamVac' deep cleaner.
FILL LINE
TANK HANDLE
Place deep cleaner handle in the upright, locked position.
To remove tank, press down on handle and pull forward.
Carry tank to a sink. Rotate tank cap counterclockwise and lift up to remove cap.
Pour detergent into tank.
Fill tank to fill line (1 gallon) with hot tap water.
To assure proper performance, use only ‘Hoover’ cleaning
detergent .
RUBBER RING
LEDGE
If rubber ring on cap has displaced, replace it with uneven side against cap ledge as shown.
Continued
Page 8
Replace cap. Rotate cap clockwise until it locks in place.
How to empty
To prevent possible leaking, remove clean solution tank by pressing down on tank handle and pulling forward; set tank aside (do not set tank on furniture).
TANK HANDLE
Turn deep cleaner off and disconnect from electrical outlet.
Step on handle release pedal and lower handle until it rests on the floor.
If cleaning stairs or upholstery, remove hose as shown on pages 11 and 12.
Rotate recovery tank latches outward (one on each side of tank).
Lift tank off of deep cleaner and carry it to a sink or drain.
Unlatch back part of tank lid and remove lid. Empty tank. Pour dirty water out from the rear of the tank.
The lid replaces in a hinge-like manner. Position the front of lid under tabs on front of tank. Rotate lid down onto tank. Make
sure that the lid is secure on all sides before placing tank on cleaner.
Replace tank and press down to ensure that it is properly seated in place.
To continue cleaning stairs or upholstery, replace hose as shown on pages 11 and 12.
Raise handle to upright position and replace upper clean solution tank.
Rotate latches (one on each side of tank) inward to lock tank in place.
Cap must be locked in place for proper performance and to prevent leaking.
REAR OF TANK
For full suction, it is important that the recovery tank lid is properly secured before cleaning.
Position bottom of tank into unit and press on tank handle to snap tank into place.
Recovery tank (lower tank)
The recovery tank holds the dirty solution that is picked up from the carpet.
When the recovery tank is full, the automatic “shut-off” will engage (see page 6) and the tank must be emptied.
TABS
LATCH
HANDLE RELEASE PEDAL
LATCH
Page 9
How to use
a. Vacuum thoroughly - For carpet, use a vacuum cleaner with an agitator for best results. Vacuum uphol­stery with a vacuum cleaner with cleaning tool attachments. Use a crevice tool to reach into tufts and folds. Do not use
the ‘SteamVac’ deep cleaner as a dry vacuum cleaner.
Before you begin cleaning
After cleaning
To clean the outside of the machine, wipe off dirt with a cloth dampened in warm water and a mild detergent. Do not use
solvent or petroleum based products to clean the machine.
Slide tool into nozzle and remove debris.
b. For upholstery, check cleaning code - Use your HOOVER ‘SteamVac’ deep cleaner only if the upholstery fabric is marked with a “W” (for “wet” clean) or “S/W” (for “solvent/dry” or “wet” clean). Do not clean fabric marked “S” (“solvent/dry” clean only). If your upholstery does not have a code, seek professional assistance.
c. Test for colorfastness - Mix detergent and water according to the instructions under "Fill clean solution tank" on pages 7 and 8. Wet a white absorbant cloth with the solution. In a small, hidden area, gently rub the surface with the dampened cloth. Wait ten minutes and check for color removal or bleed with white paper towel or cloth. If surface has more than one color, check all colors.
d. When cleaning entire floor, move furniture out of area to be cleaned (may not be necessary if only high
traffic areas are to be cleaned). For furniture too heavy to move, place aluminum foil or wax paper under legs. This will prevent wood finishes from staining carpet. Pin up furniture skirts and draperies.
e. Pretreat spots and heavy traffic areas with HOOVER® PreCleaner* - Test PreCleaner for colorfast-
ness by first spraying it on a hidden area; wait ten minutes and blot with white paper towels or cloth.
If no color change is visible, spray PreCleaner onto spots and traffic areas. Wait at least ten minutes. Use your ‘SteamVac’ deep cleaner to pick up PreCleaner and spot. Repeat until spot is removed; carefully scrub with a household scrub brush if necessary . Do not saturate carpet or upholstery with PreCleaner.
No cleaning solution removes all stains from all carpets. Stain removal varies with the type of spill, time elapsed before removal, carpet material, and carpet type.
d. Remove debris from recovery tank filter and rinse with clean water.
f. To prevent staining, use plastic or aluminum foil to protect wood or metal surfaces from possible water spray.
c. Empty tanks, rinse with clear water and let air dry. Rinse the solution tank cap and recovery tank lid and let air dry.
To rinse, follow the same procedure for cleaning only using hot tap water with no detergent in the upper clean solution tank.
If rinsing is desired, be careful not to over-wet the carpet or upholstery. Allow time for carpet or upholstery to dry
completely between cleaning and rinsing.
b. If desired, the carpet may be rinsed. Rinsing is not necessary for cleaning, but it may improve the surface’s
appearance after it is dry.
If furniture must be replaced before the carpet is dry, use plastic or aluminum foil pads under legs of furniture so metal slides or wood finishes will not stain the carpet.
If it is necessary to walk on damp carpet, place towels or white cloths on the traffic areas.
a. Allow carpet or upholstery to dry. To help prevent matting and resoiling the carpet, keep children and pets away from surface until it is completely dry.
See pages 10-14 for instructions on various cleaning tasks.
Note: If the filter must be removed for cleaning, it is easier to replace if the filter is wet.
e. If desired, vacuum thoroughly after carpet has completely dried. This will help reduce any shading left by the deep cleaner's brushes.
To clean nozzle
If lint or other debris becomes lodged in nozzle, do not attempt to remove nozzle cover.
Pour one to two cups of clear water on a non-carpeted floor.
Do not pour water onto a wood floor.
Pick up water with your ‘SteamVac’ deep cleaner. Repeat as necessary until debris is flushed out of nozzle.
If some debris is left or if a non-carpeted floor is not available, use the nozzle clean-out tool.
Disconnect cleaner from electrical outlet.
*Available at additional cost if not included with your model.
g. To avoid wetting and possible damage to wood floors underneath area rugs/carpet, either move area rugs/carpet
to a non-wood bare floor surface or place waterproof material (e.g. plastic) underneath them before cleaning.
Page 10
Cleaning carpet
Continued
Keep nozzle flat on floor for both forward and reverse strokes.
For best cleaning results and to aid in faster drying of carpet, end with more dry strokes. (Continue using dry strokes until little water is visible passing through the recovery tank lid.)
NOTE: Check the recovery tank for fullness often. Empty tank if it appears full even if automatic shut-off (pg. 6) has not engaged.
When finished cleaning, follow “After cleaning” instructions on page 9.
Release trigger and slowly push deep cleaner forward over area just sprayed with solution (dry stroke). Then slowly pull deep cleaner back toward you without squeezing trigger (dry stroke).
When finished, follow “After cleaning” instructions on page 9.
How to attach bare floor attachment
Disconnect cleaner from electrical outlet.
If a spot is left, the stair/upholstery nozzle is generally more ef­fective for removing it. Although no cleaning solution can completely remove all spots, they can be treated by following the instructions provided by the manufacturer of the carpet, up­holstery, or bare floor surface being cleaned.
For best results, pick up spills immediately by placing the stair/ upholstery nozzle just above the spill and suction up any residue on top of the carpet. If the spill remains, place either the stair/ upholstery nozzle or floor nozzle with brushes turned OFF in front of the spill, pull the nozzle very slowly over the spill initially with suction only. Repeat with spray and suction. When pick-
ing up spills on bare floors, use only the floor nozzle with the bare floor attachment in place and speed selector in the OFF position (this will help prevent spreading the spill).
Your HOOVER ‘SteamVac’ deep cleaner may also be used to pick up small liquid spills (1 gallon or less, never to exceed
1
/4 inch in depth) on carpet, upholstery, or bare floors.
Do not use the ‘SteamVac’ deep cleaner to pick up flam­mable or combustible liquids or chemicals.
Picking up spills
Read “Before you begin cleaning” instructions on page 9.
Fill clean solution tank (upper tank) according to instructions on pages 7 and 8. Use 5 ounces of HOOVER Carpet/Upholstery Detergent.
Move speed selector to LO for gentle cleaning or HI for normal cleaning.
Dry hands and plug cord into a properly grounded outlet.
Do not clean over floor electrical outlets.
To avoid walking on damp carpet, start at the end of the room farthest from the door or path to sink where tanks will be emptied and filled .
Step on handle release pedal and lower handle to operating position; turn deep cleaner ON.
Cleaning bare floors
Squeeze trigger to release cleaning solution and slowly push deep cleaner forward (equals one wet stroke). Continue to squeeze trigger and slowly pull deep cleaner back toward you (second wet stroke).
For heavily soiled areas, repeat. To avoid saturating carpet,
do not use more than 4 wet strokes over one area. Always end with dry strokes.
It is best to alternate wet and dry strokes as described above.
TANK HANDLE
To prevent possible leaking, remove clean solution tank by pressing down on tank handle and pulling forward; set tank aside (do not set tank on furniture.)
HANDLE RELEASE PEDAL
LATCH
Step on handle release pedal and lower handle until it rests on the floor.
Rotate recovery tank latches (one on each side of tank) outward; lift tank off machine.
Page 11
TAB
Unlatch back part of recovery tank lid and remove lid.
Step on handle release pedal and lower deep cleaner handle until it rests on the floor.
“LIP”
With handle in the upright position, tilt deep cleaner back so that handle rests on the floor.
Hold bare floor attachment so that end with arrow is in your left hand and arrow points toward the ceiling. Place tab on other end of attachment into groove in clear lip on front of nozzle (see illustration).
BARE FLOOR ATTACHMENT
“LIP”
To clean floor
Read “Before you begin cleaning” instructions on page 9. Do not use the 'SteamVac' deep cleaner on hardwood floors.
Fill clean solution tank according to instructions on pages 7 and
8. Use 5 ounces of HOOVER Bare Floor Cleaner.
Do not use any type of wax with your ‘SteamVac’ deep cleaner.
Move speed selector to the Lo or HI position for scrubbing or OFF if scrubbing is not desired.
Dry hands and plug deep cleaner into a properly grounded outlet.
Step on handle release pedal and lower handle to operating position; turn deep cleaner ON.
To release solution, press trigger. Slowly move deep cleaner forward and backward over area to be cleaned.
To pick up dirty solution, release trigger and slowly move deep cleaner over area where solution has just been dis­persed. Use both forward and reverse strokes.
When finished cleaning, follow “After cleaning” instructions on page 9.
Remove attachment from nozzle and rinse in clear water. Do not
remove plastic screen or foam from attachment.
Press firmly to snap end of attachment with arrow into groove opposite end of nozzle "lip".
Return deep cleaner to upright position.
LATCH
Lower handle and replace recovery tank. Press down to ensure that it is properly seated in place.
Rotate latches (one on each side of tank) inward to lock tank in place. Raise handle to upright position.
Using the stair/upholstery nozzle
How to attach hose
Disconnect deep cleaner from electrical outlet.
TANK HANDLE
To prevent possible leaking, remove clean solution tank by pressing down on tank handle and pulling forward; set tank aside (do not set tank on furniture).
Remove hose from storage rack.
HANDLE RELEASE PEDAL
Continued
Page 12
FRONT
TAB
NOZZLE CONNECTOR
PANEL
Remove recovery tank front panel by sliding it straight up.
CONVERTER
For full suction, it is important that the recovery tank lid is properly secured before cleaning.
TABS
FRONT
The tank lid is replaced in a hinge-like manner. Position front of lid under tabs on front of tank. Rotate lid down onto tank.
Make sure lid is secure on all sides before cleaning.
Reverse procedure to remove hose and solution tube.
Raise deep cleaner handle to upright position.
Replace panel with converter. Slide converter halfway down opening until it is firmly in place.
SOLUTION TUBE
Before connecting tube to cleaner, make sure black tabs are extended by pulling tan collar toward tube.
Open door on hood labeled “Stair/Upholstery Cleaning Connection”. Press round solution tube connector onto round projection inside door.
Press connector collar down firmly to ensure that it is fully connected.
Attach nozzle to connector end of hose by sliding it onto connec­tor until the tab locks it securely.
To remove nozzle, depress tab while sliding nozzle off connector. Follow the instructions on pages 13 and 14 for the appropriate
cleaning task.
When the solution tube is connected to the deep cleaner, the nozzle brushes will automatically be turned off and will not rotate when the deep cleaner is turned on even if the speed selector is in the HI or LO position.
Continued
Page 13
After using stair/upholstery nozzle
Follow the instructions for “After cleaning” on page 9.
Drain suction hose by turning deep cleaner on and holding nozzle up for several minutes. Do not press trigger.
Disconnect deep cleaner from electrical outlet.
Disconnect hose and solution tube from deep cleaner.
Drain solution tube by placing round end in sink, and raising nozzle above your head. Press the trigger.
CONVERTER
Cleaning carpeted stairs
Read “Before you begin cleaning” instructions on page 9.
Attach hose and solution tube as instructed on pages 11 and 12.
Agitator brushes will not rotate while “solution tube” is connected to deep cleaner.
Fill clean solution tank according to instructions on pages 7 and
8. Use 5 ounces of HOOVER Carpet/Upholstery Detergent. Hose length may require that machine be placed at the top of
the stairs to clean upper half of stairway and at bottom of stairs to clean lower half.
To prevent machine from falling, use extra caution when cleaning on stairs. Do not place deep cleaner on stairs.
Do not point stair/upholstery nozzle at people or pets.
Dry hands and plug deep cleaner into a properly grounded outlet.
Turn deep cleaner on.
CONVERTER CLIP
Occasionally, debris may become lodged inside of the hose at the converter end.
To clean-out the hose, lift bottom of converter clip with a screw driver and remove clip. Remove debris as shown.
SOLUTION HOSE
Snap clip back into positon making sure solution hose is not pinched and moves freely.
Replace recovery tank front panel. Slide panel down until it
snaps firmly in place.
Pre-spray the carpeted stair by holding the nozzle about one inch above the carpet and push the wand forward while pressing the solution trigger (equals one wet stroke).
Position nozzle against the riser and slightly press nozzle into carpet pile. Press the solution trigger and pull the nozzle slowly over the carpet (second wet stroke).
Release the trigger, lift nozzle, and position it against riser. Pull nozzle slowly over carpet without pressing trigger (dry stroke).
It is best to alternate wet and dry strokes as described above. End with more dry strokes to aid in faster drying of carpet.
Overlap strokes by one-half inch to help prevent streaking.
To avoid saturating carpet, do not use more than 4 wet strokes over any one area. Always end with dry strokes.
NOTE: Check the recovery tank for fullness often. Empty
tank if it appears full even if automatic shut-off (pg. 6) has not engaged.
If additional cleaning is necessary, wait until the carpet is completely dry before using the nozzle again.
When finished cleaning, follow “After cleaning” instructions on page 9 and “After using stair/upholstery nozzle” instructions on page 13.
Page 14
Cleaning upholstery and automobile interiors
Read “Before you begin cleaning” instructions on page 9. Be sure to check the cleaning code on your upholstery. Use
your HOOVER ‘SteamVac’ deep cleaner only on upholstery marked “W” or “W/S”.
Attach hose and solution tube as instructed on pages 11 and 12.
Agitator brushes will not rotate while “solution tube” is connected to deep cleaner.
Fill clean solution tank according to instructions on page 7 and
8. Use 3 ounces of HOOVER Carpet/Upholstery Detergent.
Dry hands and plug deep cleaner into a properly grounded outlet.
Turn deep cleaner on.
Gently press the nozzle onto the fabric. Press the solution trigger and slowly pull the nozzle over the fabric.
Overlap strokes by one-half inch to help prevent streaking.
Make additional strokes without pressing the trigger to remove more moisture.
To clean in corners or creases, lift the nozzle one-half inch from the fabric and press the solution trigger. Vacuum up the solution with the nozzle without pressing the trigger.
Storage
Before storing:
• Empty solution tank and rinse thoroughly with clean water.
• Replace empty solution tank and turn deep cleaner ON. Squeeze trigger and push deep cleaner forward and back several times to expel any solution remaining in the deep cleaner's system. (Do not use deep cleaner on wood floors.)
• Empty recovery tank and rinse thoroughly with clean water.
Allow brushes and underside of deep cleaner to air dry thoroughly before storing deep cleaner on a carpeted or wood surface.
Do not store deep cleaner with a full solution tank in place.
Lubrication
The motor is equipped with bearings which contain sufficient lubrication for the life of the motor. The addition of lubricant could cause damage. Do not add lubricant to motor
bearings.
For heavily soiled areas, it may be necessary to repeat the cleaning process. Make crisscrossing strokes to the original pattern; overlap each pass.
Make no more than 2 passes with the solution over any one area to prevent overwetting and damage to fabric.
NOTE: Check the recovery tank for fullness often. Empty
tank if it appears full even if automatic shut-off (pg. 6) has not engaged.
If additional cleaning is necessary, wait until the upholstery is completely dry before using the nozzle again.
When finished cleaning, follow “After cleaning” instructions on page 8 and “After using stair/upholstery nozzle” instructions on page 13.
Page 15
If you have a problem
This appliance was inspected thoroughly and was in good operating condition when it was shipped from the factory. If a minor problem occurs, it usually can be solved quite easily when the cause is found. Therefore, this check list is provided for your convenience.
Possible cause Possible solution
Machine won't run
1. Not firmly plugged in. 1. Plug unit in firmly.
2. No voltage in wall 2. Check fuse or breaker. plug.
3. Blown fuse/tripped 3. Replace fuse/reset breaker. breaker.
Low suction
1. Recovery tank lid not 1. Make sure lid is on on correctly. securely (page 8).
2. Recovery tank full/ 2. Remove and empty automatic shut-off recovery tank. engaged.
3. Obstruction in hose 3. Remove hose; clear on stair/upholstery obstruction. nozzle.
4. Recovery tank front 4. Replace recovery tank panel not replaced after front panel (page 12).
stair or upholstery cleaning.
Clean solution won't dispense
1. Solution tank not 1. Make sure tank is firmly in place. securely locked
in position.
2. Solution tank empty. 2. Refill tank according to
instructions for surface being cleaned (pages 7 & 8).
3. Recovery tank lid 3. Make sure lid is firmly in not on correctly. place (page 8).
4. Stair/upholstery 4. Make sure tube is solution tube not securely fastened securely fastened. at connection of hood.
Solution tube on stair/upholstery nozzle won't connect
1. Connector collar 1. Extend black tabs on pushed forward. connector by pulling
collar toward tube.
Brushes/brush indicator won't rotate during floor cleaning
1. Indicator screen dirty. 1. Remove clear cover over indicator and clean screen. Replace cover (see page 6).
2. Speed selector on OFF. 2. Move speed selector to LO or HI.
3. Solution tube connected 3. Remove stair/upholstery
to “Stair/Upholstery nozzle for floor cleaning. Cleaning Connection”. (see page 12)
Service
To obtain approved HOOVER service and genuine HOOVER parts, locate the nearest Hoover Factory
Service Center or Authorized Hoover Warranty Ser­vice Dealer (Depot) by:
checking the Yellow Pages under “Vacuum Cleaners - Household” OR -
checking the list of Factory Service Centers provided with this cleaner OR -
calling 1-800-944-9200 for an automated referral of authorized service outlet locations (U.S. only).
Do not send your cleaner to The Hoover Company in North Canton for service, this will only result in delay.
If further assistance is needed, contact The Hoover Company Consumer Response Center, North Canton, Ohio 44720 Phone: 330-499-9499.
In Canada, contact Hoover Canada, Burlington, Ontario L7R 4A8, Phone: 1-800-263-6376.
Always identify your cleaner by the complete model number when requesting information or ordering parts. (The model number appears on the back of the cleaner handle.)
Page 16
HOOVER and are registered trademarks
THE HOOVER COMPANY, NORTH CANTON, OHIO 44720
R1 8-96 F5853-/57-/61-/63-900 Litho USA 56518-086
Loading...