Review this manual before operating deep cleaner.
Record and Retain
This HOOVER deep cleaner is designed for deep cleaning of
carpet, and rugs. It can also be used to clean carpeted stairs
and upholstery.
The model and serial numbers are located on the data label
on the back of the deep cleaner handle.
For your personal records, please enter the COMPLETE
model and serial numbers in the spaces provided and retain
this information.
Your deep cleaner is model
and has serial number
It is suggested that you attach your sales receipt to this
owner’s manual. Verification of date of purchase may be
required for warranty service of your Hoover product.
Grounding Instructions
This appliance must be grounded. If it should malfunction or
breakdown, grounding provides a path of least resistance for
electrical current to reduce the risk of electric shock. This
appliance is equipped with a cord having an equipmentgrounding conductor and grounding plug (A). The plug must
be plugged into an appropriate outlet (B) that is properly
installed and grounded in accordance with all local codes and
ordinances.
(A)
GROUNDING PIN
(B)
DANGER-
Improper connection of the equipment-grounding conductor
can result in the risk of electric shock. Check with a qualified
electrician or service person if you are in doubt as to whether
the outlet is properly grounded. Do not modify the plug
provided with the appliance - if it will not fit the outlet, have a
proper outlet installed by a qualified electrician. This appliance
is for use on a nominal 120 volt circuit and has a grounding
plug that looks like the plug illustrated in sketch (A).
Index
Important safeguards .....................................................2
Unpacking deep cleaner.................................................2
Assembling deep cleaner........................................... 3-5
Deep cleaner description ...............................................5
General operation ...........................................................6
Filling the clean solution tank ............................ 7-8
Emptying the recovery tank....................................8
A temporary adapter (C) may be used to connect this plug to a
2-pole receptacle (D) if a properly grounded outlet is not
available. The temporary adapter should be used only until a
properly grounded outlet (B) can be installed by a qualified
electrician. The green colored rigid ear, lug, or the like
extending from the adapter must be connected to a permanent
ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal
screw.
ADAPTER
(C)
NOTE: In Canada, the use of a temporary adaptor is not
permitted by the Canadian Electrical Code.
TAB FOR
GROUNDING
SCREW
METAL SCREW
(D)
Page 2
WARNING:
To reduce the risk of fire, electric
shock, or injury:
When using an electrical appliance, always follow
basic precautions, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
Important Safeguards!
Questions or Concerns?
• Use indoors only.
• Use only on surfaces moistened by the cleaning process or small
spills. Do not immerse product.
• Connect to a properly grounded outlet only. See “Grounding Instructions”.
• Do not clean over floor electrical outlets.
• Do not use without tanks in place.
• Use extra care when cleaning on stairs. Do not place deep cleaner on
stairs.
• Use deep cleaner only for its intended use as described in the instructions. Use only attachments recommended by The Hoover Company;
others may cause hazards.
• The use of an extension cord is not recommended. If an extension
cord is absolutely necessary, use at least a 16 gauge 3-wire cord which
has a 3-prong grounding type plug and a 3-pole receptacle that accepts
the machine plug.
• Unplug deep cleaner when not in use. Turn off all controls before
unplugging.
• Always disconnect cord from electrical outlet before servicing the
deep cleaner.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the
cord. Never handle plug or appliance with wet hands.
• Do not pull or carry by cord, use cord as a handle, close door on cord or
pull cord around sharp edges or corners. Do not run appliance over
cord. Keep cord away from heated surfaces.
• Do not use with damaged cord or plug. If appliance is not working as it
should, has been dropped, damaged, left outdoors, or dropped into
water, take it to a Hoover Factory Service Center or Authorized Hoover
Warranty Service Dealer.
• Close supervision is necessary when any appliance is used by or
near children. Do not allow deep cleaner to be used as a toy or to run
unattended at any time.
• Do not point stair/upholstery tool toward people or pets.
• Use only commercially available floor cleaners intended for machine
application. Do not use any type of wax with deep cleaner.
• To assist in reducing drying time, be certain the area is well ventilated
when using detergents and other cleaners with this machine.
• Keep detergents and other cleaners out of children’s reach.
• Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
• Do not pick up chlorine bleach, drain cleaner, gasoline or any other
toxic material with this appliance.
• Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
• Avoid picking up hard, sharp objects with the deep cleaner. They may
damage the machine.
• Keep hair, loose clothing, fingers, feet and all parts of body away
from openings and moving parts. Do not operate deep cleaner in bare
feet or when wearing open toe shoes or sandals.
• Do not put any object into openings. Do not use with any opening
blocked; keep free of dust, lint, hair, and anything that may reduce
air flow.
• To help prevent matting and resoiling, avoid contact with carpets until
they are dry. Keep children and pets away from carpets until they
are completely dry.
• Store in a dry place. Do not expose machine to freezing temperatures.
The Hoover Company wants to quickly resolve any
concerns about your cleaner or questions regarding its use. Look on the list provided with the
product for your local Hoover Factory ServiceCenter or in the Yellow Pages under “Vacuum
Cleaners - Household” for the nearest Authorized
Hoover Warranty Service Dealer (Depot) or call:
1-800-944-9200 for an automated referral
of authorized service outlet locations (U.S. only) or
1-330-499-9499 (U.S.) and 1-800-263-6376
(Canada) to speak with a Hoover representative.
DO NOT RETURN THIS PRODUCT TO THE
STORE OR SEND IT TO NORTH CANTON
FOR SERVICE.
Unpack deep cleaner from the carton and
identify the parts shown. Remove and dispose
of the cardboard packing and tape securing
rotating brushes for shipping purposes only.
Unpacking
Save these instructions!
J
A
A. Deep cleaner
B. Upper handle with hose/nozzle rack
C. Bolts (2)
D. Nuts (3 - one extra included)
E. Carpet/Upholstery Detergent (some models
come with 2 bottles)
F. Bare Floor Cleaner (some models come with
2 bottles)
G. PreCleaner (included with some models)
H. Bare floor attachment
I. Hose
J. Stair/upholstery nozzle
K. Lower hose hook and screw
L. Nozzle clean-out tool
CD
I
B
L
G
E
F
K
H
Page 3
Continued ➜
5
Assembling deep
cleaner
The assembled cleaner will look like this drawing.
4
Push bolts into holes on front of handle (Fig. 4).
If bolts will not go through hole easily handle is not pushed
completely down.
Attach upper handle
1
Remove clean solution tank
(upper tank) (Fig. 1).
2
Remove nozzle stored on upper
handle by gently pushing nozzle
downward while pivoting it away
from the handle at (B).
3
CORD
HOOK
(B)
Place nuts in recessed areas on back of handle. Hold each
nut in place while tightening each bolt securely with a Phillips
screw driver (Fig. 5).
Only two nuts are needed on this model. The extra nut is not
required but has been provided for your convenience.
6
SQUEEZE
TRIGGER
When handle sections are completely together, squeeze
trigger on upper handle to snap trigger rod in place (Fig. 6).
7
TANK
HANDLE
With cord hook to back of deep cleaner, push
upper handle down onto lower handle. (Fig.3).
Replace clean solution tank (upper tank) by positioning bottom
first. Press on tank handle to snap top of tank into place (Fig. 7).
Page 4
8
12
HANDLE
NOZZLE
CONNECTOR
Press cord into cord clip on back of handle.
Pull cord tightn (Fig. 8).
Attach lower hose holder
9
PROJECTIONS
With front of deep cleaner resting on floor, place 2 projections
on lower hose holder into 2 holes on back of cleaner (Fig 9).
HOSE
HOLDER
HOLES
CORD
HOOK
To store hose on rack, begin by placing nozzle connector end
of hose (straight end) into clip 1 on rack (Fig. 12).
13
4
CLIP 1
CLIP 1
2
2
1
2
10
Push screw into hole and tighten securely with a Phillips screw
driver (Fig 10).
Storing hose and nozzle on rack
11
Stretch hose out and identify ends.
Note: You may find it helpful when storing the hose and nozzle
to refer to the information on the back of the deep cleaner
and on the converter end of the hose (Fig. 11).
NOZZLE CONNECTOR
END OF HOSE
TRIGGER
SOLUTION
HOSE
CONVERTER
END OF HOSE
3
Secure hose to rack at numbered locations as shown.
(Fig. 13)
14
EXTENSION
HOOK
Converter is stored in area as
shown.
While aligning arrows (Fig. 14), place extension into bottom of
converter opening; then push converter firmly against deep
cleaner until it snaps into place.
To remove, first pull top of converter off extension then pull off
bottom.
Secure solution hose to converter as shown.
Page 5
Deep cleaner description
1.Hand grip
2.Solution trigger: press to release clean solution.
3.Hose
4.Hose holders: wrap hose around holders for storage.
5.Cord hooks: wrap cord around hooks for storage.
The top hook can be rotated right or left for quick and easy
cord release.
6.Stair/upholstery nozzle
7.Carrying handle
8.Clean solution tank handle
9.Clean solution tank cap/ measuring cup
10. Clean solution tank: holds cleaning solution.
11. Recovery tank lid
12. Recovery tank: holds dirty solution.
13. Recovery tank “front panel”
14. Hood
15. Agitator speed selector: slide selector to set brush
speed on HI, LO, or OFF.
16. Brush indicator: spins when brushes are rotating.
17. Nozzle
18. Upholstery and stair cleaning connection: push door
open to connect stair/upholstery tool “solution tube”.
19. Recovery tank latches: one on each side of tank.
20. ON/OFF pedal
21. Handle release pedal: step on pedal to lower handle
to operating position.
The assembled deep cleaner will look like the drawing below.
15
(B)
TAB (A)
The nozzle is stored in the area between the cord hooks (Fig. 15).
Place brushes of nozzle on top of Tab (A) as shown. Gently
push the nozzle downward while pivoting it into the nozzle
holder (B).
19
18
2
1
3
4
5
6
7
8
9
5
10
11
12
13
14
4
15
16
17
20
21
19
This deep cleaner is intended for household use.
Page 6
General operation
ON/OFF
PEDAL
Operate deep cleaner only at voltage specified on data plate
on back of cleaner.
ON/OFF pedal
Plug deep cleaner into a properly grounded outlet.
Step on pedal to turn deep cleaner on. Step on pedal again to
turn deep cleaner off.
Handle release pedal
To transport
Turn deep cleaner off before transporting.
To move your deep cleaner from room to room, put handle in
upright and locked position, tilt deep cleaner back on wheels,
and push forward.
HANDLE
RELEASE
PEDAL
Step on pedal to lower handle to operating position. Handle
does not lock into a single position but “floats” to allow convenient operation.
Automatic “shut-off”
FLOAT DISK
When the recovery tank (lower tank) is full, the automatic “shutoff”mechanism will shut off the deep cleaner suction.
At that time, the red float disk will rise to the top of the recovery
tank lid (see illustration). The deep cleaner will no longer pick
up dirty solution and the motor sound will become noticeably
higher in pitch.
When this happens, turn deep cleaner off and empty recovery
tank before continuing use.
The deep cleaner may also be lifted by placing a hand under
the upper clean solution tank handle as shown.
Agitator speed selector
Your ‘SteamVac’ deep cleaner has three agitator brush settings.
HI - for normal cleaning of carpet and bare floors
LO - for gentle cleaning of carpets and bare floors
OFF - for cleaning carpets and bare floors when
brushing is not desired. (Such as when picking up
liquid spills. See page 10.)
Slide selector button to the desired setting before cleaning.
NOTE: Check the recovery tank often. Empty tank when it
appears full even if the automatic shut-off has not engaged.
Check clean solution tank also; it may need to be refilled.
Page 7
Turn cap upside down to serve as a measuring cup.
Fill cap to upper “carpet” fill line(5 ounces) with HOOVER
Carpet/Upholstery Detergent.
For bare floors:
Fill cap to upper "carpet” fill line (5 ounces) with HOOVER
Bare Floor Cleaner
TANK CAP
Brush indicator
5 OUNCES
(carpet)
3 OUNCES
(upholstery)
The brush indicator will spin
when the deep cleaner is
turned on and the brushes
are rotating.
There are three reasons why the brushes may not be rotating:
1. Brush speed selector set on OFF. (See previous section.)
2. Solution tube connected (page 12).
3. Brush indicator screen dirty.
To clean screen, turn deep cleaner off and disconnect from
electrical outlet.
SCREEN
Remove clear cover and wipe off screen with a damp cloth.
Snap cover back into position.
If the indicator does not spin
and the pattern is visible
when the deep cleaner is
turned on, the brushes are
not rotating.
The tanks
Clean solution tank (upper tank)
The clean solution tank holds the cleaning solution that is to be
dispersed onto the surface to be cleaned.
How to fill
Disconnect deep cleaner from electrical outlet.
Using cap, measure detergent following the chart below.
For carpet and carpeted stairs:
Do not use any type of wax with your ‘SteamVac’ deep
cleaner.
Do not use Bare Floor Cleaner on carpet or upholstery.
For upholstery:
Fill cap to lower “upholstery” fill line (3 ounces) with
HOOVER Carpet/Upholstery Detergent.
NOTE: Use only HOOVER detergents. They are specially
formulated for use with your 'SteamVac' deep cleaner.
FILL LINE
TANK
HANDLE
Place deep cleaner handle in the upright, locked position.
To remove tank, press down on handle and pull forward.
Carry tank to a sink.
Rotate tank cap counterclockwise and lift up to remove cap.
Pour detergent into tank.
Fill tank to fill line (1 gallon) with hot tap water.
To assure proper performance, use only ‘Hoover’ cleaning
detergent .
RUBBER
RING
LEDGE
If rubber ring on cap has displaced, replace it with uneven side
against cap ledge as shown.
Continued ➜
Page 8
Replace cap.Rotate cap clockwise until it locks in place.
How to empty
To prevent possible leaking, remove clean solution tank by
pressing down on tank handle and pulling forward; set tank
aside (do not set tank on furniture).
TANK
HANDLE
Turn deep cleaner off and disconnect from electrical outlet.
Step on handle release pedal and lower handle until it rests on
the floor.
If cleaning stairs or upholstery, remove hose as shown on
pages 11 and 12.
Rotate recovery tank latches outward (one on each side of tank).
Lift tank off of deep cleaner and carry it to a sink or drain.
Unlatch back part of tank lid and remove lid.
Empty tank. Pour dirty water out from the rear of the tank.
The lid replaces in a hinge-like manner. Position the front of
lid under tabs on front of tank. Rotate lid down onto tank. Make
sure that the lid is secure on all sides before placing tank on
cleaner.
Replace tank and press down to ensure that it is properly seated
in place.
To continue cleaning stairs or upholstery, replace hose as
shown on pages 11 and 12.
Raise handle to upright position and replace upper clean
solution tank.
Rotate latches (one on each side of tank) inward to lock tank
in place.
Cap must be locked in place for proper performance and to
prevent leaking.
REAR OF
TANK
For full suction, it is important that the
recovery tank lid is properly secured before
cleaning.
Position bottom of tank into unit and press on tank handle to
snap tank into place.
Recovery tank (lower tank)
The recovery tank holds the dirty solution that is picked up from
the carpet.
When the recovery tank is full, the automatic “shut-off” will
engage (see page 6) and the tank must be emptied.
TABS
LATCH
HANDLE
RELEASE
PEDAL
LATCH
Page 9
How to use
a.Vacuum thoroughly - For carpet, use a vacuum
cleaner with an agitator for best results. Vacuum upholstery with a vacuum cleaner with cleaning tool attachments.
Use a crevice tool to reach into tufts and folds. Do not use
the ‘SteamVac’ deep cleaner as a dry vacuum cleaner.
Before you begin cleaning
After cleaning
To clean the outside of the machine, wipe off dirt with a cloth
dampened in warm water and a mild detergent. Do not use
solvent or petroleum based products to clean the machine.
Slide tool into nozzle and remove debris.
b.For upholstery, check cleaning code - Use your
HOOVER ‘SteamVac’ deep cleaner only if the upholstery
fabric is marked with a “W” (for “wet” clean) or “S/W” (for
“solvent/dry” or “wet” clean). Do not clean fabric marked“S” (“solvent/dry” clean only). If your upholstery does not
have a code, seek professional assistance.
c.Test for colorfastness - Mix detergent and water
according to the instructions under "Fill clean solution tank"
on pages 7 and 8. Wet a white absorbant cloth with the
solution. In a small, hidden area, gently rub the surface
with the dampened cloth. Wait ten minutes and check for
color removal or bleed with white paper towel or cloth. If
surface has more than one color, check all colors.
d.When cleaning entire floor, move furniture out of
area to be cleaned (may not be necessary if only high
traffic areas are to be cleaned). For furniture too heavy to
move, place aluminum foil or wax paper under legs. This
will prevent wood finishes from staining carpet. Pin up
furniture skirts and draperies.
e.Pretreat spots and heavy traffic areas with
HOOVER® PreCleaner* - Test PreCleaner for colorfast-
ness by first spraying it on a hidden area; wait ten minutes
and blot with white paper towels or cloth.
If no color change is visible, spray PreCleaner onto spots
and traffic areas. Wait at least ten minutes. Use your
‘SteamVac’ deep cleaner to pick up PreCleaner and spot.
Repeat until spot is removed; carefully scrub with a
household scrub brush if necessary . Do not saturate
carpet or upholstery with PreCleaner.
No cleaning solution removes all stains from all carpets.
Stain removal varies with the type of spill, time elapsed
before removal, carpet material, and carpet type.
d. Remove debris from recovery tank filter and rinse with clean
water.
f. To prevent staining, use plastic or aluminum foil to
protect wood or metal surfaces from possible water spray.
c. Empty tanks, rinse with clear water and let air dry. Rinse
the solution tank cap and recovery tank lid and let air dry.
To rinse, follow the same procedure for cleaning only using hot
tap water with no detergent in the upper clean solution tank.
If rinsing is desired, be careful not to over-wet the carpet or
upholstery. Allow time for carpet or upholstery to dry
completely between cleaning and rinsing.
b. If desired, the carpet may be rinsed. Rinsing is not
necessary for cleaning, but it may improve the surface’s
appearance after it is dry.
If furniture must be replaced before the carpet is dry, use
plastic or aluminum foil pads under legs of furniture so metal
slides or wood finishes will not stain the carpet.
If it is necessary to walk on damp carpet, place towels or white
cloths on the traffic areas.
a. Allow carpet or upholstery to dry. To help prevent matting
and resoiling the carpet, keep children and pets away from
surface until it is completely dry.
See pages 10-14 for instructions on various cleaning tasks.
Note: If the filter must be removed for cleaning, it is easier to
replace if the filter is wet.
e. If desired, vacuum thoroughly after carpet has completely
dried. This will help reduce any shading left by the deep
cleaner's brushes.
To clean nozzle
If lint or other debris becomes lodged in nozzle, do not
attempt to remove nozzle cover.
Pour one to two cups of clear water on a non-carpeted floor.
Do not pour water onto a wood floor.
Pick up water with your ‘SteamVac’ deep cleaner. Repeat as
necessary until debris is flushed out of nozzle.
If some debris is left or if a non-carpeted floor is not available,
use the nozzle clean-out tool.
Disconnect cleaner from electrical outlet.
*Available at additional cost if not included with your
model.
g. To avoid wetting and possible damage to wood floors
underneath area rugs/carpet, either move area rugs/carpet
to a non-wood bare floor surface or place waterproof
material (e.g. plastic) underneath them before cleaning.
Page 10
Cleaning carpet
Continued➚
Keep nozzle flat on floor for both forward and reverse strokes.
For best cleaning results and to aid in faster drying of carpet,
end with more dry strokes. (Continue using dry strokes until
little water is visible passing through the recovery tank lid.)
NOTE: Check the recovery tank for fullness often. Empty
tank if it appears full even if automatic shut-off (pg. 6) has not
engaged.
When finished cleaning, follow “After cleaning” instructions on
page 9.
Release trigger and slowly push deep cleaner forward over
area just sprayed with solution (dry stroke). Then slowly pull
deep cleaner back toward you without squeezing trigger (dry
stroke).
When finished, follow “After cleaning” instructions on page 9.
How to attach bare floor attachment
Disconnect cleaner from electrical outlet.
If a spot is left, the stair/upholstery nozzle is generally more effective for removing it. Although no cleaning solution can
completely remove all spots, they can be treated by following
the instructions provided by the manufacturer of the carpet, upholstery, or bare floor surface being cleaned.
For best results, pick up spills immediately by placing the stair/
upholstery nozzle just above the spill and suction up any residue
on top of the carpet. If the spill remains, place either the stair/
upholstery nozzle or floor nozzle with brushes turned OFF in
front of the spill, pull the nozzle very slowly over the spill initially
with suction only. Repeat with spray and suction. When pick-
ing up spills on bare floors, use only the floor nozzle with
the bare floor attachment in place and speed selector in the
OFF position (this will help prevent spreading the spill).
Your HOOVER ‘SteamVac’ deep cleaner may also be used to
pick up small liquid spills (1 gallon or less, never to exceed
1
/4inch in depth) on carpet, upholstery, or bare floors.
Do not use the ‘SteamVac’ deep cleaner to pick up flammable or combustible liquids or chemicals.
Picking up spills
Read “Before you begin cleaning” instructions on page 9.
Fill clean solution tank (upper tank) according to instructions on
pages 7 and 8. Use 5 ounces of HOOVER Carpet/Upholstery
Detergent.
Move speed selector to LO for gentle cleaning or HI for
normal cleaning.
Dry hands and plug cord into a properly grounded outlet.
Do not clean over floor electrical outlets.
To avoid walking on damp carpet, start at the end of the room
farthest from the door or path to sink where tanks will be emptied
and filled .
Step on handle release pedal and lower handle to operating
position; turn deep cleaner ON.
Cleaning bare floors
Squeeze trigger to release cleaning solution and slowly push
deep cleaner forward (equals one wet stroke). Continue to
squeeze trigger and slowly pull deep cleaner back toward you
(second wet stroke).
For heavily soiled areas, repeat. To avoid saturating carpet,
do not use more than 4 wet strokes over one area. Always
end with dry strokes.
It is best to alternate wet and dry strokes as described above.
TANK
HANDLE
To prevent possible leaking, remove clean solution tank by
pressing down on tank handle and pulling forward; set tank
aside (do not set tank on furniture.)
HANDLE
RELEASE
PEDAL
LATCH
Step on handle release pedal and lower handle until it rests on
the floor.
Rotate recovery tank latches (one on each side of tank)
outward; lift tank off machine.
Page 11
TAB
Unlatch back part of recovery tank lid and remove lid.
Step on handle release pedal and lower deep cleaner handle
until it rests on the floor.
“LIP”
With handle in the upright position, tilt deep cleaner back so that
handle rests on the floor.
Hold bare floor attachment so that end with arrow is in your left
hand and arrow points toward the ceiling. Place tab on other
end of attachment into groove in clear lip on front of nozzle
(see illustration).
BARE FLOOR
ATTACHMENT
“LIP”
To clean floor
Read “Before you begin cleaning” instructions on page 9.
Do not use the 'SteamVac' deep cleaner on hardwood floors.
Fill clean solution tank according to instructions on pages 7 and
8. Use 5 ounces of HOOVER Bare Floor Cleaner.
Do not use any type of wax with your ‘SteamVac’ deep
cleaner.
Move speed selector to the Lo or HI position for scrubbing
or OFF if scrubbing is not desired.
Dry hands and plug deep cleaner into a properly grounded
outlet.
Step on handle release pedal and lower handle to operating
position; turn deep cleaner ON.
To release solution, press trigger. Slowly move deep cleaner
forward and backward over area to be cleaned.
To pick up dirty solution, release trigger and slowly move
deep cleaner over area where solution has just been dispersed. Use both forward and reverse strokes.
When finished cleaning, follow “After cleaning” instructions on
page 9.
Remove attachment from nozzle and rinse in clear water. Do not
remove plastic screen or foam from attachment.
Press firmly to snap end of attachment with arrow into groove
opposite end of nozzle "lip".
Return deep cleaner to upright position.
LATCH
Lower handle and replace recovery tank. Press down to ensure
that it is properly seated in place.
Rotate latches (one on each side of tank) inward to lock
tank in place. Raise handle to upright position.
Using the stair/upholstery nozzle
How to attach hose
Disconnect deep cleaner from electrical outlet.
TANK
HANDLE
To prevent possible leaking, remove clean solution tank by
pressing down on tank handle and pulling forward; set tank aside
(do not set tank on furniture).
Remove hose from storage rack.
HANDLE
RELEASE
PEDAL
Continued ➜
Page 12
FRONT
TAB
NOZZLE CONNECTOR
PANEL
Remove recovery tank front panel by sliding it straight up.
CONVERTER
For full suction, it is important that the recovery
tank lid is properly secured before cleaning.
TABS
FRONT
The tank lid is replaced in a hinge-like manner. Position front
of lid under tabs on front of tank. Rotate lid down onto tank.
Make sure lid is secure on all sides before cleaning.
Reverse procedure to remove hose and solution tube.
Raise deep cleaner handle to upright position.
Replace panel with converter. Slide converter halfway down
opening until it is firmly in place.
SOLUTION
TUBE
Before connecting tube to cleaner,
make sure black tabs are extended
by pulling tan collar toward tube.
Open door on hood labeled “Stair/Upholstery Cleaning
Connection”. Press round solution tube connector onto round
projection inside door.
Press connector collar down firmly to ensure that it is fully
connected.
Attach nozzle to connector end of hose by sliding it onto connector until the tab locks it securely.
To remove nozzle, depress tab while sliding nozzle off connector.
Follow the instructions on pages 13 and 14 for the appropriate
cleaning task.
When the solution tube is connected to the deep
cleaner, the nozzle brushes will automatically be
turned off and will not rotate when the deep cleaner is
turned on even if the speed selector is in the HI or LO
position.
Continued ➚
Page 13
After using stair/upholstery nozzle
Follow the instructions for “After cleaning” on page 9.
Drain suction hose by turning deep cleaner on and holding
nozzle up for several minutes. Do not press trigger.
Disconnect deep cleaner from electrical outlet.
Disconnect hose and solution tube from deep cleaner.
Drain solution tube by placing round end in sink, and raising
nozzle above your head. Press the trigger.
CONVERTER
Cleaning carpeted stairs
Read “Before you begin cleaning” instructions on page 9.
Attach hose and solution tube as instructed on pages 11 and 12.
Agitator brushes will not rotate while “solution tube” is
connected to deep cleaner.
Fill clean solution tank according to instructions on pages 7 and
8. Use 5 ounces of HOOVER Carpet/Upholstery Detergent.
Hose length may require that machine be placed at the top of
the stairs to clean upper half of stairway and at bottom of
stairs to clean lower half.
To prevent machine from falling, use extra caution when
cleaning on stairs. Do not place deep cleaner on stairs.
Do not point stair/upholstery nozzle at people or pets.
Dry hands and plug deep cleaner into a properly grounded
outlet.
Turn deep cleaner on.
CONVERTER
CLIP
Occasionally, debris may become lodged inside of the hose at
the converter end.
To clean-out the hose, lift bottom of converter clip with a screw
driver and remove clip. Remove debris as shown.
SOLUTION
HOSE
Snap clip back into positon making sure solution hose is not
pinched and moves freely.
Replace recovery tank front panel. Slide panel down until it
snaps firmly in place.
Pre-spray the carpeted stair by holding the nozzle about one
inch above the carpet and push the wand forward while
pressing the solution trigger (equals one wet stroke).
Position nozzle against the riser and slightly press nozzle into
carpet pile. Press the solution trigger and pull the nozzle
slowly over the carpet (second wet stroke).
Release the trigger, lift nozzle, and position it against riser.
Pull nozzle slowly over carpet without pressing trigger (dry
stroke).
It is best to alternate wet and dry strokes as described above.
End with more dry strokes to aid in faster drying of carpet.
Overlap strokes by one-half inch to help prevent streaking.
To avoid saturating carpet, do not use more than 4 wet
strokes over any one area. Always end with dry strokes.
NOTE: Check the recovery tank for fullness often. Empty
tank if it appears full even if automatic shut-off (pg. 6) has not
engaged.
If additional cleaning is necessary, wait until the carpet is
completely dry before using the nozzle again.
When finished cleaning, follow “After cleaning” instructions on
page 9 and “After using stair/upholstery nozzle” instructions on
page 13.
Page 14
Cleaning upholstery and
automobile interiors
Read “Before you begin cleaning” instructions on page 9.
Be sure to check the cleaning code on your upholstery. Use
your HOOVER ‘SteamVac’ deep cleaner only on upholstery
marked “W” or “W/S”.
Attach hose and solution tube as instructed on pages 11 and 12.
Agitator brushes will not rotate while “solution tube” is
connected to deep cleaner.
Fill clean solution tank according to instructions on page 7 and
8. Use 3 ounces of HOOVER Carpet/Upholstery Detergent.
Dry hands and plug deep cleaner into a properly groundedoutlet.
Turn deep cleaner on.
Gently press the nozzle onto the fabric. Press the solution
trigger and slowly pull the nozzle over the fabric.
Overlap strokes by one-half inch to help prevent streaking.
Make additional strokes without pressing the trigger to remove
more moisture.
To clean in corners or creases, lift the nozzle one-half inch from
the fabric and press the solution trigger. Vacuum up the solution
with the nozzle without pressing the trigger.
Storage
Before storing:
• Empty solution tank and rinse thoroughly with clean
water.
• Replace empty solution tank and turn deep cleaner
ON. Squeeze trigger and push deep cleaner forward
and back several times to expel any solution remaining
in the deep cleaner's system. (Do not use deep
cleaner on wood floors.)
• Empty recovery tank and rinse thoroughly with clean
water.
Allow brushes and underside of deep cleaner to air
dry thoroughly before storing deep cleaner on a
carpeted or wood surface.
Do not store deep cleaner with a full solution tank in
place.
Lubrication
The motor is equipped with bearings which contain sufficient
lubrication for the life of the motor. The addition of lubricant
could cause damage. Do not add lubricant to motor
bearings.
For heavily soiled areas, it may be necessary to repeat the
cleaning process. Make crisscrossing strokes to the original
pattern; overlap each pass.
Make no more than 2 passes with the solution over any one
area to prevent overwetting and damage to fabric.
NOTE: Check the recovery tank for fullness often. Empty
tank if it appears full even if automatic shut-off (pg. 6) has not
engaged.
If additional cleaning is necessary, wait until the upholstery is
completely dry before using the nozzle again.
When finished cleaning, follow “After cleaning” instructions on
page 8 and “After using stair/upholstery nozzle” instructions on
page 13.
Page 15
If you have a problem
This appliance was inspected thoroughly and was in good
operating condition when it was shipped from the factory.
If a minor problem occurs, it usually can be solved quite
easily when the cause is found. Therefore, this check list is
provided for your convenience.
Possible causePossible solution
Machine won't run
1. Not firmly plugged in.1. Plug unit in firmly.
2. No voltage in wall2. Check fuse or breaker.
plug.
Always identify your cleaner by the complete model
number when requesting information or ordering parts.
(The model number appears on the back of the cleaner
handle.)
Page 16
HOOVER and are registered trademarks
THE HOOVER COMPANY, NORTH CANTON, OHIO 44720
R1 8-96 F5853-/57-/61-/63-900Litho USA 56518-086
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.