Hoover F5857-900, F5851 Owner’s Manual

®
TM
The Easy to Use Deep
Caeaner
ENGL/SH ,_ pp. 1-16
JESPANOL =_ pag.18-33 I FRAN(_AIS 4 p. 35-48
operating deep cmea.ero
Necord and Netain
This HOOVER deep cleaner is designed for deep cleaning of carpet, and rugs. It can also be used to clean carpeted stairs and upholstery.
The model and serial numbers are located on the data label
on the back of the deep cleaner handle.
For your personal records, please enter the COMPLETE model and serial numbers in the spaces provided and retain this information.
Your deep cleaner is model
and has serial number ........
It is suggested that you attach your sales receipt to this owner's manual. Verification of date of purchase may be
required for warranty service of your Hoover product.
Index
Important safeguards ..................................................... 2
Unpacking deep cleaner ................................................. 2
Assembling deep cleaner ........................................... 3=5
Deep cleaner description ............................................... 5
General operation ........................................................... 6
Filling the clean solution tank ............................ 7-8
Emptying the recovery tank .................................... 8
Agitator speed selector ........................................... 6
Brush indicator ........................................................ 7
How to use
Before you begin ...................................................... 9
After cleaning ........................................................... 9
Cleaning carpet ...................................................... 10
Picking up spills ..................................................... 10
Cleaning bare floors ........................................ 10-11
Using the stair/upholstery nozzle ................... 11-12
Cleaning carpeted stairs ................................ 13
Cleaning upholstery ....................................... 14
If you have a problem ................................................... 15
Lubrication ..................................................................... 15
Service .......................................................................... 16
Storage .......................................................................... 15
This cleaner was inspected and packaged carefully before being shipped from the factory. If you should happen to need
assistance during assembly or operation, call
1-800-944-9200 for an automated referral of authorized
service outlet locations (U.S only) or
1-330-499-9499 (U.S) and 1-800-263-6376 (Canada) to speak with a Hoover representative.
PLEASE DO NOT RETURN THIS PRODUCT
TO THE STORE.
Grounding Mnstructions
This appliance must be grounded. Ifit should malfunction or breakdown, grounding provides a path of least resistance for
electrical current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment-
grounding conductor and grounding plug (A). The plug must
be plugged into an appropriate outlet (B) that is properly installed and grounded in accordance with all local codes and
ordinances.
GROUNDING PIN (B)
I
Improper connection of the equipment-grounding conductor can result in the risk of electric shock. Check with a qualified
electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance
is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in sketch (A).
A temporary adapter (C) may be used to connect thisplug to a 2-pole receptacle (D) if a properly grounded outlet is not
available. The temporary adapter should be used only until a
properly grounded outlet (B) can be installed by a qualified
electrician. The green colored rigid ear, lug, or the like
extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. When-
ever the adapter is used, it must be held in place by a metal screw.
APTER
TAB FOR
(C) _ GROUNDING
METAL SCREW -
SCREW
(B)
NOTE: In Canada, the use of a temporary adaptor is not permitted by the Canadian Electrical Code.
© 1995, 1996, 2001 The Hoover Company www.hoover.com
P/N 56518119
important Safegua s, w
When using an electrical appliance, always follow
basic precautions, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
WARNING: To reduce the risk of fire, electric
= Use indoors only. shock, or injury: * Use only on surfaces moistened by the cleaning process or small
spills. Do not immerse product. Connect to a properly grounded outlet only. See "Grounding Instruc-
tions".
. Do not clean over floor electrical outlets. , Do not use without tanks in place. o Use extra care when cleaning on stairs. Do not place deep cleaner on
stairs.
. Use deep cleaner only for its intended use as described in the instruc-
tions. Use only attachments recommended by The Hoover Company; others may cause hazards.
. The use of an extension cord is not recommended. If an extension
cord is absolutely necessary, use at least a 16 gauge 3owire cord which has a 3-prong grounding type plug and a 3-pole receptacle that accepts
the machine plug.
- Unplug deep cleaner when not in use. Turn off all controls before unplugging.
o Always disconnect cord from electrical outlet before servicing the
deep cleaner.
o Do not unplug by pulling on cord. To unplug, grasp the plug, not the
cord. Never handle plug or appliance with wet hands.
o Do not pull or carry by cord, use cord as a handle, close door on cord or
pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
. Do not use with damaged cord or plug. If appliance is not working as it
should, has been dropped, damaged, left outdoors, or dropped into water, take it to a Hoover Factory Service Center or Authorized Hoover
Warranty Service Dealer.
o Close supervision is necessary when any appliance is used by or
near children. Do not allow deep cleaner to be used as a toY or to run unattended at any time.
. Do not point stair/upholstery tool toward people or pets. ° Use only commercially available floor cleaners intended for machine
application. Do not use any type of wax with deep cleaner.
o To assist in reducing drying time, be certain the area is well ventilated
when using detergents and other cleaners with this machine.
° Keep detergents and other cleaners out of children's reach. ° Do not use to pick up flammable or combustible liquids such as gaso-
line or use in areas where they may be present.
° Do not pick up chlorine bleach, drain cleaner, gasoline or any other
toxic material with this appliance.
° Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
° Avoid picking up hard, sharp objects with the deep cleaner. They may
damage the machine.
. Keep hair, loose clothing, fingers, feet and all parts of body away
from openings and moving parts. Do not operate deep cleaner in bare feet or when wearing open toe shoes or sandals.
° Do not put any object into openings. Do not use with any opening
blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
° To help prevent matting and resoiling, avoid contact with carpets until
they are dry. Keep children and pets away from carpets until they are completely dry.
. Store in a dry place. Do not expose machine to freezing temperatures.
[] []
Questions or Concerns?
The Hoover Company wants to quickly resolve any concerns about your cleaner or questions regard-
ing its use. Look on the list provided with the product for your local Hoover Factory Service
Center or in the Yellow Pages under "Vacuum Cleaners - Household" for the nearest Authorized
Hoover Warranty Service Dealer (Depot) or call:
1-800-944-9200 for an automated referral
of authorized service outlet locations (U.S. only) or
1-330-499-9499 (U.S.) and 1-800-263-6376
(Canada) to speak with a Hoover representative.
PLEASE DO NOT RETURN THIS PRODUCT
TO THE STORE OR SEND IT TO NORTH
CANTON FOR SERVICE.
Unpacking
Unpack deep cleaner from the carton and identify the parts shown. Remove and dispose of the cardboard packing and tape securing rotating brushes for shipping purposes only.
c E FG
A
A. Deep cleaner B. Upper handle with hose/nozzle rack
C. Bolts (2) D. Nuts (3 - one extra included)
E. Carpet/Upholstery Detergent + F. Bare Floor Cleaner * *
G. PreCleaner * H. Bare floor attachment *
I. Hose J. Stair/upholstery nozzle
K. Lower hose hook and screw L. Nozzle clean-out tool *
*included with some models
*Some models come with 2 bottles
SteamVac TM Deep Clea,ter cKeans carpet fibers by appiyi.g hot tap
waiter a.d cleani.g soluitio,.
B
2 Safeguards - Unpacking oAssembly
Assembm[ng deep
cleaner
The assembled cleaner will look like this drawing,
i
_ush bolts into holes on front of handle (Fig. 4),
If bolts will not go through hole easily handle is not pushed
completely down.
Attach upper haadme
Remove clean solution tank (upper tank) (Fig. 1),
Remove nozzle stored on upper handle by gently pushing nozzle
downward while pivoting it away from the handle at (B)
!
Place nuts in recessed areas on back of handle, Hold each nut in place while tightening each bolt securely with a Phillips
screw driver (Fig, 5). Only two nuts are needed on this model. The extra nut is not
required but has been provided for your convenience.
!_SQUEEZE
; ll_ TRIG GER
When handle sections are completely together, squeeze trigger on upper handle to snap trigger rod in place (Fig. 6).
/
CORD HOOK
With cord hook to back of deep cleaner, push upper handle down onto lower handle. (Fig.3).
\
Replace clean solution tank (upper tank) by positioning bottom first. Press on tank handle to snap lop of tank into place (Fig, 7).
Continued -_
Assembly 3
Press cord into cord clip on back of handle,
Pull cord tight (Fig. 8).
Attach lower hose ho|der
NOZZLE CONNECTOR
CLIP 1
HOOK
CLIP 1
HOSE HOLDER
With front of deep cleaner resting on floor, place 2 projections on lower hose holder into 2 holes on back of cleaner (Fig 9).
Push screw into hole and tighten securely with a Phillips screw
driver (Fig 10).
1
Stori.g hose and nozzle on rack
To store hose on rack, begin by placing nozzle connector end of hose (straight end) into clip 1 on rack (Fig. 12).
_ i/1 2
Secure hose to rack at numbered locations as shown. (Fig. 13)
EXTENSION
HOOK
ALIGN ARROW
& HOOK FOR CONVERTER
END OF HOSE
NOZZLE CONNECTOR _
Stretch hose out and identify ends. Note: You may find it helpful when storing the hose and nozzle
to refer to the information on the back of the deep cleaner
and on the converter end of the hose (Fig. 11).
4 Assembly
Converter is stored in area as shown.
While aligning arrows (Fig. 14), place extension into bottom of converter opening; then push converter firmly against deep
cleaner until it snaps into place.
To remove, first pull top of converter off extension then pull off
bottom.
Secure solution hose to converter as shown.
!iii i!ii!,!iiiiilil
. v
The nozzle is stored in the area between the cord hooks (Fig. 15).
Place brushes of nozzle on top of Tab (A) as shown. Gently push the nozzle downward while pivoting it into the nozzle
holder (B),
@÷ep emeaaer deseriptJea
The assembled deep cleaner will look like the drawing below.
2
1
3
5 4
!
6-,
s.,
4
I
20
21
1. Hand grip
2. Solution trigger: press to release clean solution.
3. Hose
4. Hose holders: wrap hose around holders for storage.
5. Cord hooks: wrap cord around hooks for storage.
The top hook can be rotated right or left for quick and easy
cord release.
6. Stair/upholstery nozzle
7. Carrying handle
8. Clean solution tank handle
9. Clean solution tank cap! measuring cup
10. Clean solution tank: holds cleaning solution.
11. Recovery tank lid
12. Recovery tank: holds dirty solution.
13. Recovery tank."front panel"
14. Hood
15. Agitator speed selector: slide selector toset brush speed on HI, LO, or OFF.
16. Brush indicator: spins when brushes are rotating.
17. Nozzle
18. Upholstery and stair cleaning connection: push door open to connect stair/upholstery tool "solution tube"
19. Recovery tank latches: one on each side of tank.
20. ON/OFF pedal
21. Handle release pedal: step on pedal to lower handle to operating position.
19
This deep cleaner is intended for household use.
Assembly- Deep cleaner description 5
Genera[ operation
Operate deep cleaner only at voltage specified on data plate on back of cleaner,
ON/OFF pedal
ON/OFF
PEDAL
Plug deep cleaner into a properly grounded outlet.
Step on pedal to turn deep cleaner on. Step on pedal again to turn deep cleaner off.
Handle release pedal
To transport
Turn deep cleaner off before transporting.
To move your deep cleaner from room to room, put handle in upright and locked position, tilt deep cleaner back on wheels,
and push forward.
RELEASE PEDAL
Step on pedal to lower handle to operating position. Handle does not lock into a single position but "floats" to allow conve-
nient operation,
When the recovery tank (lower tank) is full, the automatic "shut- off"mechanism will shut off the deep cleaner suction.
At that time, the red or yellow float disk will rise to the top of the recovery tank lid (see illustration). The deep cleaner will "no longer pick up dirty solution and the motor sound will become noticeably higher in pitch.
When this happens, turn deep cleaner off and empty recovery tank before continuing use.
Check clean solution tank also; it may need to be refilled.
The deep cleaner may also be lifted by placing a hand under
the upper clean solution tank handle as shown.
Agitator speed selector
Your 'SteamVac' deep cleaner has three agitator brush settings.
HI - for normal cleaning of carpet and bare floors
LO - for gentle cleaning of carpets and bare floors
OFF - for cleaning carpets and bare floors when
brushing is not desired. (Such as when picking up liquid spills. See page 10.)
Slide selector button to the desired setting before cleaning.
6 General operation - Agitator speed selector
Brush i.dicator
The brush indicator will spin If the indicator does not spin when the deep cleaner is and the pattern is visible turned on and the brushes when the deep cleaner is are rotating, turned on, the brushes are
not rotating.
There are three reasons why the brushes may not be rotating:
1. Brush speed selector set on OFF. (See previous section.)
2. Solution tube connected (page 12).
3. Brush indicator screen dirty. To clean screen, turn deep cleaner off and disconnect from
electrical outlet.
TANK CAP
5 OUNCES
Turn cap upside down to serve as a measuring cup.
Using cap, measure detergent following the chart below.
For carpet, carpeted stairs and upholstery:
Fill cap to fill line (5 ounces) With HOOVER Carpet/Upholstery Detergent.
For bare floors:
Pill cap to fill line (5 ounces) with HOOVER Bare Floor Cleaner
Do not use any type of wax with your 'SteamVac' deep
cleaner.
Do not use Bare Floor Cleaner on carpet or upholstery.
NOTE: Use only HOOVER detergents. They are specially
formulated for use with your 'SteamVac' deep cleaner.
For heavy traffic areas: Pro-treat with HOOVER PreCleaner Spray. It you do not have access to the PreCleaner Spray,
double the amount of HOOVER Detergent (use 2 capfuls or 10 ounces per 1 gallon tank).
Remove clear cover and wipe off screen with a damp cloth.
Snap cover back into position.
The tanks
Clean solution tank (upper tank)
The clean solution tank holds the cleaning solution that is to be
dispersed onto the surface to be cleaned.
How 1o fill
Disconnect deep cleaner from electrical outlet.
Place deep cleaner handle in the upright, locked _osition.
To remove tank, press down on handle and pull forward.
CAUTION: Detergents.contain Anionic and Nonionic
Surfactants. Avoid contact with eyes and skin. In case of contact with eyes, flus with cold water for 15 minutes. In
case of contact with skin, wash with water. If irritation persists, call a physician. For Medical Information (U.S.) call 1-800-752-7869
FILL LINE
Pour detergent into tank.
Fill tank to fill line (1 gallon) with hot tap water.
To assure proper performance, use only 'Hoover' cleaning detergent.
RING
Carry tank to a sink. Rotate tank cap counterclockwise and lift up to remove cap.
, , LEDGE
(_ RUBBER
If rubber ring on cap has displaced, replace it with uneven side
against cap ledge as shown. CORtilllUed "_
Brushindicator- Filling solutiontank 7
Replace cap. Rotate cap clockwise until it locks in place. Cap must be locked in place for proper performance and to
revent leaking.
/
Position bottom of tank into unit and press on tank handle to snap tank into place.
Recovery tank (tower tank)
The recovery tank holds the dirty solution that is picked up from the carpet.
When the recovery tank is full, the automatic "shut-off" will engage (see page 6) and the tank must be emptied.
How to empty
REAR OF
TANK
Unlatch back part of tank lid and remove lid. Empty tank, Pour dirty water out from the rear of the tank.
TABS
The lid replaces in a hinge-like manner. Position the front of lid under tabs on front of tank Rotate lid down onto tank. Make
sure that the lid is secure on all sides before placing tank on cleaner.
S! JIL//
Turn deep cleaner off and disconnect from electrical outlet. To prevent possible leaking, remove clean solution tank by
pressing down on tank handle and pulling forward; set tank aside (do not set tank on furniture).
PEDAL
LATCH
Step on handle release pedal and lower handle until it rests on the floor,
If cleaning stairs or upholstery, remove hose by reversing procedure as shown on page t2.
Rotate recovery tank latches outward (one on each side of tank),
LATCH"
For full suction, it is important that the
recovery tank lid is properly secured before cleaning.
Replace tank and press down to ensure that it is properly seated in place.
Rotate latches (one on each side of tank) inward to lock tank
in place.
To continue cleaning stairs or upholstery, replace hose as shown on pages 11 and 12.
Raise handle to upright position and replace upper clean solution tank.
Lift tank off of deep cleaner and carry it to a sink or drain.
8 Filling solution tank - Emptying recovery tank
H@w t@ use
Before you begi. emea.i.g
a, Vacuum thoroughly- For carpet, use a vacuum cleaner with an agitator for best results. Vacuum uphol- stery with a vacuum cleaner with cleaning tool attachments.
Use a crevice tool to reach into tufts and folds. Do not use
the 'SteamVac' deep cleaner as a dry vacuum cleaner.
b. For upholstery, check cleaning code - Use your HOOVER 'SteamVac' deep cleaner only if the upholstery
fabric is marked with a "W" (for "wet" clean) or "S/W" (for
"solvent/dry" or "wet" clean). Do not clean fabric marked "S" ("solvent/dry" clean only). If your upholstery does not have a code, seek professional assistance,
c. Test for colorfastness - Mix detergent and water according to the instructions under "FINclean solution tank" on pages 7 and 8. Wet a white absorbant cloth with the
solution. In a small, hidden area, gently rub the surface with the dampened cloth. Wait ten minutes and check for
color removal or bleed with white paper towel or cloth. If surface has more than one color, check all colors.
d. When cleaning entire floor, move furniture out of area to be cleaned (may not be necessary if only high
traffic areas are to be cleaned). For furniture too heavy to
move, place aluminum foil or wax paper under legs. This
will prevent wood finishes from staining carpet. Pin up
furniture skirts and draperies. e. Pretreat spots and heavy traffic areas with
HOOVER@ PreCleaner* - Test PreCleaner for colorfast- ness by first spraying it on a hidden area; wait ten minutes and blot with white paper towels or cloth.
If no color change is visible, spray PreCleaner onto spots and traffic areas. Wait at least ten minutes Use your
'SteamVac' deep cleaner to pick up PreCleaner and spot. Repeat until spot is removed; care[ully scrub with a
household scrub brush if necessary, Do not saturate carpet or upholstery with PreCleaner.
No cleaning solution removes all stains from all carpets. Stain removal varies with the type of spill, time elapsed before removal, carpet material, and carpet type.
If you do not have access to the PreCleaner Spray, doubk
the amount of HOOVER detergent (use 2 capfuls or 10 oz. per 1 gallon) in the clean solution tank.
*Available at additional cost if not included with your
model.
f. To prevent staining, use plastic or aluminum foil to
protect wood or metal surfaces from possible water spray.
g,To avoid wetting and possible damage to wood floors underneath area rugs/carpet, either move area rugs/carpet
to a non-wood bare floor surface or place waterproof
material (e.g. plastic) underneath them before cleaning.
After cJeaning
a. Allow carpet or upholstery to dry. To help prevent matting and resoiling the carpet, keep children and pets away from surface until it is completely dry.
If it is necessary to walk on damp carpet, place towels or white cloths on the traffic areas.
If furniture must be replaced before the carpet is dry, use plastic or aluminum _oil pads under legs of furniture so metal
slides or wood finishes will not stain the carpet.
b. If desired, the carpet may be rinsed. Rinsing is not necessary for cleaning, but it may improve the surface's
appearance after it is dry.
If rinsing is desired, be careful not to over-wet the carpet or
upholstery, Allow time for carpet or upholstery to dry completely between cleaning and rinsing.
To rinse, follow the same procedure for cleaning only using hot
tap water with no detergent in the upper clean solution tank. c. Empty tanks, rinse with clear water and let air dry, Rinse
the solution tank cap and recovery tank lid and let air dry.
/
d. Remove debris from recovery tank filter and rinse with clean
water. Note: If the filter must be removed for cleaning, it is easier to replace if the filter is wet.
e. If desired, vacuum thoroughly after carpet has completely dried. This will help reduce any shading left by the deep
cleaner's brushes.
To clean nozzme
If lintor other debris becomes lodged in nozzle, do not attempt to remove nozzle cover.
Pour one to two cups of clear water on a non-carpeted floor Do not pour water onto a wood floor.
Pick up water with your 'SteamVac' deep cleaner, Repeat as necessary until debris is flushed out of nozzle.
Some models have a nozzle clean-out tool, as shown below, for
removing debris or if a non-carpeted floor is not available.
Disconnect cleaner from electrical outlet.
See pages 10-14 for instructions on various cleaning tasks.
To clean the outside of the machine, wipe off dirt with a cloth dampened in warm water and a mild detergent. Do not use
solvent or petroleum based products to clean the machine,
Before you begin - After cleaning 9
Read "Before you begin cleaning" instructions on page 9.
1. Fill clean solution tank (upper tank) according to instructions on pages 7 and 8. Use 5 ounces of HOOVER Carpet/Upholstery Detergent.
2. Move speed selector to LO for gentle cleaning or HI for normal cleaning.
3. Dry handsand plug cord intoaproperly groundedoutlet. Do not clean over floor electrical outlets.
4. To avoid walking on damp carpet, start at the end of the room farthest from the door or path to sink where tanks will be emptied and filled.
Step on handle release pedal and lower handle to operating position; turn deep cleaner ON.
Your HOOVER 'SteamVac' deep cleaner may also be used to
pick up small liquid spills (1 gallon or less, never to 1/4inch in depth) on carpet, upholstery, or bare floors.
For best results, pick up spills immediately by placing the stair/ upholstery nozzle just above the spill and suction up any residue on top of the carpet. If the spin remains, place either the stair/
upholstery nozzle or floor nozzle with brushes turned OFF in front of the spill. Pull the nozzle very slowly over the spill initially
with suction only. Repeat with spray and suction. When pick- ing up spills on bare floors, use only the floor nozzle with
the bare floor attachment in place and speed selector in the OFF position (this will help prevent spreading the spill).
tf a spot is left, the stair/upholstery nozzle is generally more ef-
fective Ior removing it. Although no cleaning solution can
completely remove all spots, they can be treated by following
the instructions provided by the manufacturer of the carpet, up-
holstery, or bare floor surface being cleaned.
Do not use the 'SteamVac' deep cleaner to pick up flam- mable or combustible liquids or chemicals.
When finished1 follow "Alter cleaning" instructions on page 9.
exceed
How to attach bare floor attachme.t
Disconnect cleaner from electrical outlet,
5. Squeeze trigger to release cleaning solution and slowly push deep cleaner forward (equals one wet stroke).
6. Continue to squeeze trigger and slowly pull deep cleaner back toward you (second wet stroke).
Release trigger and slowly push deep cleaner forward over area just sprayed with solution (dry stroke). Then slowly pull
deep cleaner back toward you without squeezing trigger (dry stroke).
7. Overlap strokes by one inch to help prevent streaking. Keep nozzle flat on floor for both forward and reverse strokes.
For heavily soiled areas, repeat steps 5-7. To avoid saturating
carpet, do not use more than 4 wet strokes over one area. Always end with dry strokes.
It is best to alternate wet and dry strokes as described above.
For best cleaning results and to aid in faster drying of carpet, end with mere dry strokes. (Continue using dry strokes until
little water is visible passing through the recovery tank lid.)
When finished cleaning, follow "After cleaning" instructions on
page 9.
/
TANK
HANDLE
To prevent possible leaking, remove clean solution tank by
pressing down on tank handle and pulling forward; set tank aside (do not set tank on furniture.)
F PEDAL
LATCH
Step on handle release pedal and lower handle until it rests on the floor.
Rotate recovery tank latches (one on each side of tank) outward; lift tank off machine.
10 Cleaning carpet - Picking up spills - Cleaning bare floors
Continued
FOAM STRIP
With handle in upright position, tilt deep cleaner back so that handle rests on the floor.
Place attachment on front of nozzle with foam strip (under netting) in position as shown.
To c|ean fleer
Read "Before you begin cleaning" instructions on page 9. Do not use the 'SteamVac' deep cleaner on hardwood floors.
Filt clean solution tank according to instructions on pages 7 and 8 Use 5 ounces of HOOVER Bare Floor Cleaner.
Do not use any type of wax with your 'SteamVac' deep
cleaner.
Move speed selector to the Lo or HI position for scrubbing or OFF if scrubbing is not desired.
Dry hands and plu9 deep cleaner into a properly grounded
outlet.
Step on handle release pedal and lower handle to operating position; turn deep cleaner ON.
To release solution, press trigger. Slowly move deep cleaner forward and backward over area to be cleaned,
To pick up dirty solution, release trigger and slowly move deep cleaner over area where solution has just been dis-
persed. Use both forward and reverse strokes.
When finished cleaning, lollow "After cleaning" instructions on page 9.
Remove attachment from nozzle and rinse in clear water Do not remove plastic screen or foam from attachment.
Push attachment against lip while rotating attachment downward until both ends "snap" into place.
(Note: Some force may be required to rotate and snap attachment into place.)
Return deep cleaner to upright position.
LATCH
Lower handle and replace recovery tank. Press down 1oensure
that it is properly seated in place.
Rotate latches (one on each side of tank) inward to lock
tank in place. Raise handle to upright position.
How to attach hose
Disconnect deep cleaner from electrical outlet.
To prevent possible leaking, remove clean solution tank by pressing down on tank handle and pulling forward; set tank aside
(do not set tank on furniture).
Remove hose from storage rack.
HANDLE RELEASE
PEDAL
Step on handle release pedal and bowerdeep cleaner handle until it rests on the floor.
Unlatch back part of recovery tank lid and remove lid.
Continued 4
Cleaningbare floors - Using stair/upholsterynozzle 11
Remove recovery tank front panel By sliding it straight up.
Replace panel wilh converter. Slide converter halfway down
opening until it is firmly in place,
SOLUTION TUBE
TABS
The tank lid is replaced in a hinge-like manner. Position front
of lid under tabs on front of tank, Rotate lid down onto tank
Make sure lid is secure on all sides before cleaning:
For full suction, it is important that the recovery tank lid is properly secured before cleaning.
Reverse procedure to remove hose and solution tube.
Raise deep cleaner handle to upright position.
___t /
Before connecting tube to cleaner, make sure black tabs are extended
by pulling tan collar toward tube.
Open door on hood labeled "Stair/Upholstery Cleaning Connection". Press round solution tube connector onto round
projection inside door
Press connector collar down firmly to ensure that it is fully
connected.
When the solution tube is connected to the deep cleaner, the nozzle brushes will automatically be
turned off and will not rotate when the deep cleaner is turned on even if the speed selector is in the HI or LO
position.
Continued ._
NOZZLE CONNECTOR
Attach nozzle to connector end of hose by sliding it onto connec- tor until the tab locks it securely,
Using your thumb, push forward and up on the latch to remove nozzle
Follow the instructions on pages 13 and 14 for the appropriate cleaning task.
12 Using stair/upholstery nozzle
After usi.g stair/upho|stery nozzle
Follow the instructions for "After cleaning" on page 9.
Drain suction hose by turning deep cleaner ON and holding nozzle up for several minutes. Do not press trigger,
Disconnect deep cleaner from electrical outlet. Disconnect hose and solution tube from deep cleaner,
Drain solution tube by placing round end in sink, and raising nozzle above your head. Press the trigger.
Read "Before you begin cleaning" instructions on page 9.
Attach hose and solution tube as instructed on pages 11 and 12.
Agitator brushes will not rotate while "solution tube" is connected to deep cleaner,
Fill clean solution tank according to instructions on pages 7 and
8. Use 5 ounces of HOOVER CarpeL/Upholstery Detergent. Hose length may require that machine be placed at the top of
the stairs to clean upper half of stairway and at bottom of
stairs to clean lower half,
To prevent machine from falling, use extra caution when cleaning on stairs. Do not place deep cleaner on stairs.
Do not point stair/upholstery nozzle at people or pets.
Dry hands and plug deep cleaner into a properly grounded
outlet.
Turn deep cleaner ON,
Occasionally, debris may become lodged inside of the hose at the converter end.
To clean-out the hose, lift bottom of converter clip with a screw driver and remove clip. Remove debris as shown.
SOLUTION HOSE
Snap clip back into positon making sure solution hose is not pinched and moves freely.
Pre-spray the carpeted stair by holding the nozzle about one inch above the carpet and push the wand forward while pressing the solution trigger (equals one wet stroke).
I
Position nozzle against the riser and slightly press nozzle into carpet pile. Press the solution trigger and pull the nozzle slowly over the carpet (second wet stroke).
Release the trigger, lift nozzle, and position it against riser. Pull nozzle slowly over carpet without pressing trigger (dry stroke).
It is best to alternate wet and dry strokes as described above.
End with more dry strokes to aid in faster drying of carpet.
Overlap strokes by one-half inch to help prevent streaking.
To avoid saturating carpet, do not use more than 4 wet strokes over any one area. Always end with dry strokes.
Replace recovery tank front panel, Slide panel down until it snaps firmly in place.
If additional cleaning is necessary, wait until the carpet is
completely dry before using the nozzle again.
When finished cleaning, follow "After cleaning" instructions on
page 9 and "After using stair/upholstery nozzle" instructions on page 13.
Stair/upholstery nozzle - Cleaning carpeted stairs 13
Read "Before you begin cleaning" instructions on page 9. Be sure to check the cleaning code on your upholstery. Use
your HOOVER 'SteamVac' deep cleaner only on upholstery
marked "W" or "W/S".
Attach hose and solution tube as instructed on pages 11 and 12.
Agitator brushes will not rotate while "solution tube" is connected to deep cleaner,
Fill clean solution tank according to instructions on page 7 and 8, Use 5 ounces of HOOVER Carpet/Upholstery Detergent.
Dry hands and plug deep cleaner into a properly grounded
outlet.
Turn deep cleaner ON,
P,emovab|e brushes
Your deep cleaner is equipped with removable brushes for easy cleaning.
To remove brushes
Disconnect cleaner from electrical outlet.
To prevent possible leaking, remove clean solution tank and recovery tank. Set tanks aside,
Press handle release pedal to lower handle. Turn cleaner over so bottom is facing up.
Gently press the nozzle onto the fabric. Press the solution trigger and slowly pull the nozzle over the fabric.
©verlap strokes by one-half inch to help prevent streaking.
Make additional strokes without pressing the trigger to remove more moisture.
To clean in corners or creases, lift the nozzle one-half inch from the fabric and press the solution trigger. Vacuum up the solution
with the nozzle without pressing the trigger.
For heavily soiled areas, it may be necessary to repeat the cleaning process, Make crisscrossing strokes to the original pattern; overlap each pass.
Make no more than 2 passes with the solution over any one
area to prevent overwetting and damage to fabric.
If additional cleaning is necessary, wait until the upholstery is completely dry before using the nozzle again.
When finished cleaning, follow "After cleaning" instructions on
page 8 and "After using stair/upholstery nozzle" instructions on page 13.
Grasp inner portion of brush (A) and pull brush assembly out slightly to reveal latches (B).
........ .i
. _'/ J __ 11
1 I/
Press all four latches (B) and pull brush block out. The brushes can be cleaned under running water.
To replace brushes
Align posts (C) on both ends of brush assembly with slots (D)
in cleaner housing. Make sure that square post (E) also aligns with square hole (F). Turn brushes slightly until post fits easily into hole,
14 Cleaning upholstery
Pressbrushassemblyfirmlytosnapintoplace.
Storage
Before storing:
Empty solution tank and rinse thoroughly with clean
water.
Replace empty solution tank and turn deep cleaner ON. Squeeze trigger and push deep cleaner forward and back several times to expel any solution remaining in the deep cleaner's system. (Do not use deep
cleaner on wood floors.) ,, Empty recovery tank and rinse thoroughly with clean
water.
Allow brushes and underside of deep cleaner to air dry thoroughly before storing deep cleaner on a
carpeted or wood surface. Do not store deep cleaner with a full solution tank in
place.
Lubrication
The moter is equipped with bearings which contain sufficient
lubrication for the life of the motor. The addition of lubricant
could cause damage. Do not add lubricsnt to motor
bearings.
mfyou have a probHem
If a minor problem occurs, it usually can be solved quite
easily when the cause is found by using the check list below.
Possible cause
Possible solution
. Not firmly plugged in
Plug unit in firmly o No voltage in wall plug
, Check fuse or breaker
Blown fuse/tripped breaker , Replace fuse/reset breaker
Possible cause
Possible solution
° Recovery tank lid not oncorrectly
o Make sure lid is on securely (page 8) ° Recovery tank full/automatic shut off engaged
° Remove and empty recovery tank
Obstruction in hose on stair/upholstery nozzle
o Remove hose; clear obstruction o Recovery tank front panel not replaced after stair or
upholstery cleaning
o Replace recovery tank frontpanel (page 12)
= ao _ -. I e* *
Possible cause
Possible solution
, Solution tank not firmly in place
Make sure tank is securely locked in position , Solution tank empty
Refill tank according to instructions for surface being cleaned
(pages 7 & 8)
Recovery tank lid not on correctly o Make sure lid is firmly in place (page 8)
Stair/upholstery solution tube not securely fastened ° Make sure tube is securely fastened at connection of hood
Possible cause
Possible solution
° Connector collar pushed forward
= Extend black tabs on connector by pulling collar towards tube
Possible cause
Possible solution
Indicator screen dirty. o Remove clear cover over indicator and clean screen. Replace
cover (see page 7).
, Speed selector on OFF.
Move speed selector to Low or Hi. oSolution tube connected to "Stair/Upholstery Cleaning
Connection".
° Remove stair!upholstery nozzle for floor cleaning. (see page 12)
15
Service
To obtain approved HOOVER service and genuine HOOVER parts, locate the nearest Hoover Factory
Service Center or Authorized Hoover Warranty Ser- vice Dealer (Depot) by:
® checking the Yellow Pages under "Vacuum
Cleaners - Household" OR -
,, checking the list of Factory Service Centers
provided with this cleaner OR -
calling 1-800-944-9200 for an automated referral of authorized service outlet locations
(US. only) OR -
checking the Service section of The Hoover Company on-line at www.hoover.com
Do not send your cleaner to The Hoover Company in North Canton for service, this will only result in delay.
If further assistance is needed, contact The Hoover Company Consumer Response Center, North Canton,
Ohio 44720 Phone: 1-330-499-9499. In Canada, contact Hoover Canada, Burlington, Ontario L7R 4A8, Phone: 1-800-263-6376.
Always identify your cleaner by the complete model number when requesting information or ordering parts.
(The model number appears on the back of the cleaner handle.)
16