Honeywell Home T87N, T87K Owner's Manual

Owner’s Manual
4
English: Page 1
Mode d’emploi
Français : Page 6
Manual de Uso
Español: Página 11
T87N/ T87K
This manual covers the following models:
• Heat-only T87K • Heat and Cool T87N
Pre-installation checklist
®
Check package contents:
• Thermostat
• Wall anchors & screws (2 each)
Before you begin, make sure you have:
• No. 2 Phillips & small pocket screwdrivers
• Hammer
• Level (optional)
• Pencil
• Drill and bit (3/16” for drywall, 7/32” for plaster)
Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions
can damage the product or cause a hazardous condition.
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.
This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material—special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate
69-1958EFS-0
T87N/T87K • Owner's Manual
Product application
This thermostat provides electronic control of:
• 24 VAC heating systems (T87K)
• 24 VAC heating and cooling systems (T87N)
System Types
• Gas or oil heat (T87K)
• Gas, oil, or electric heat with air
conditioning (T87N)
• Warm air, hot water, high-efficiency furnaces, heat pumps, steam, gravity
• Heat only
• Heat only with fan (T87N)
• Heat only, 2-wire, and 3-wire hot­water valve (power open and close valves) (T87K)
• Cool only (T87N)
System Settings (T87N)
• Heat, Off, Cool
Installation tips
Install the thermostat about 5 feet (1.5 m) above the floor in an area with good air circulation at average temperature.
Fan Settings (T87N)
• Auto, On
Specifications
Temperature Range
• 40° to 90°F (4.5° to 32°C)
Shipping Temperature
• 20° to 120°F (28.9° to 48.9°C)
Operating Relative Humidity
• 5% to 90% (non-condensing)
Electrical Ratings
• Voltage: 2030 VAC
• Running current:0.021.0A
NO
NO
Do not install in locations where the thermostat can be affected by:
• Drafts or dead spots behind doors and in corners
• Hot or cold air from ducts
• Sunlight or radiant heat from appliances
• Concealed pipes or chimneys
• Unheated/uncooled areas such as an outside wall behind the thermostat
69-1958EFS—04 2
NO
English: Page 1 • Français : Page 6 • Español: Página 11
Wallplate installation
1. Pull wires through wire hole. Position wallplate on wall, level, and mark hole positions.
2. Drill holes (3/16” for drywall, 7/32” for plaster) and tap in supplied wall anchors.
3. Pull wire through wallplate, position over anchors, then insert and tighten mounting screws. Check level if desired.
Wiring
1. Loosen screw terminals, insert wires into terminal block, then re-tighten screws.
2. Push excess wire back into the wall opening.
3. Plug the wall opening with nonflammable insulation to prevent drafts from affecting thermostat operation.
Terminal DesignationsT87N
W Heat relay. Y Compressor contactor. G Fan relay. O Heat pump changeover valve
energized in cooling.
Rc Cooling power. Connect to secondary
side of cooling system transformer.
R Heating power. Connect to secondary
side of heating system transformer.
B Heat pump changeover valve
energized in heating.
NOTES R & Rc terminals (T87N)
In single-transformer system, leave metal jumper in place between metal jumper if two-transformer system.
3 69-1958EFS—04
R & Rc. Remove
Terminal DesignationsT87K
W Heat relay. R Power. Connect to secondary side of
heating system transformer.
Y This terminal can be used for some
3-wire hot-water valve systems (power open and close valves).
R
W
Y
Heat pump systems (T87N)
If wiring to a heat pump, use a small piece of wire (not supplied) to connect terminals W and Y.
Wire specifications
Use 18-gauge thermostat wire. Shielded cable is not required.
T87N/T87K • Owner's Manual
Fan operation settings (T87N)
Fan operation settings: F: For gas or oil heating systems, leave the
fan operation switch in this factory-set position (for systems that control the fan in a call for heat).
E: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the ther­mostat to control the fan in a call for heat, if a fan wire is connected to the G termi­nal.)
Cycle rate settings
Heating System Switch 1 Switch 2
Steam or gravity (1 CPH) On On High efficiency warm air Off On
(90%+), hot water, or heat pump (3 CPH)
Gas or oil warm air Off Off (factory setting) (5 CPH)
Electric warm air (9 CPH) On Off
Move the cycle rate switches to the proper setting for your system (see table below).
Thermostat mounting
Base
Thermostat
69-1958EFS—04 4
Align the slots on the base with tabs on the thermostat, then push gently until the thermostat snaps into place.
Operation
English: Page 1 • Français : Page 6 • Español: Página 11
System switch (T87N)
Cool: Controls the cooling system.
Heat: Controls the heating system.
Off: All systems are off.
Temperature
Desired indoor temperature. Current indoor temperature.
Fan switch (T87N)
On: Fan runs continuously.
Auto: Fan runs only when
heating or cooling system is on.
Temperature setting
Rotate to set desired indoor temperature.
CAUTION: EQUIPMENT DAMAGE HAZARD (T87N)
Do not operate cooling system when outdoor temperature is below 50°F (10°C).
Limited 5-year warranty
Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of five (5) years from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).
If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to
the place from which you purchased it; or (ii) call Resideo Customer Care at 18004681502. Customer
Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replace­ment product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the product was in the possession of a consumer.
Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, IN CLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
5 69-1958EFS—04
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of inciden­tal or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE FIVE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 18004681502.
Loading...
+ 11 hidden pages