Honeywell Home RTH111, RTH111B1042 Owner's Manual

RTH111
Series
RTH111B1042
Owner’s Manual
Read before installing
For help please visit honeywellhome.com
Identify System Type
This thermostat is compatible with the following systems:
Gas, oil or electric furnace
Central air conditioner
Hot water system with or without pump
Millivolt system
Central heating and cooling system
Heat pump without auxiliary/backup heat
Heat Off Cool
Fan
Auto On
Do you need assistance? We are here to help.
Call 18004681502 for wiring assistance before returning the thermostat to the store.
This thermostat cannot be used on heat pumps with backup heat or on multistage systems.
ATTENTION: MERCURY RECYCLING
SANS MERCURE
M32707
NOTICE
This product does not contain mercury.
Hg
However, this product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash.
For more information on how and where to
NO MERCURY
properly recycle a thermostat containing mercury in the United States, please refer to the Thermostat Recycling Corporation at www.thermostat-recycle.org.
For mercury thermostat recycling in Canada, please refer to Switch the Stat at www.switchthestat.ca
NOTICE: To avoid possible compressor damage, do not run air conditioner if the outside temperature drops below 50 °F (10 °C).
Customer assistance
For assistance with this product, please visit
honeywellhome.com
Or call Resideo Customer Care toll-free at
18004681502.
To save time, please note your model number and date code before calling.
Pull at bottom to remove thermostat from wallplate.
Turn thermostat over to find model number and date code.
RTHXXXX
2
Table of contents
Installation
Installation ....................................................... 3
Advanced Installation ................................8
About your new thermostat
Controls and Home screen
quick reference ........................................... 10
Compressor protection...........................11
Replace batteries .......................................11
Appendices
Troubleshooting .........................................12
Limited warranty ........................................ 13
1 Turn Off Power to Heating/Cooling System
or
Circuit breaker
box
Heating/cooling system
power switch
3
2 Remove Old Thermostat
M32731
Remove old thermostat but leave wallplate with wires attached.
If you have an older thermostat with
Do not remove wallplate yet
a sealed mercury tube, turn to page 2 for proper disposal instructions.
Terminal designation
C
C
3 Label Wires with Tags
Label the wires using the supplied wire labels as you disconnect them.
Wire Labels
C
C
www.honeywellhome.com
Terminal designation
4 Separate Wallplate from New Thermostat
Remove wallplate from the new thermostat and mount onto wall.
TO REMOVE WALLPLATE
PULL HERE
Wallplate
4
5 Mount Wallplate
M32714
Mount the new wallplate using the included screws and anchors.
Not
W/
Used
Aux
Drill 3/16-in. (4,76 mm ) holes for drywall Drill 3/32-in. (2,38 mm ) holes for plaster
6 Connect Wires
Simply match wire labels. If labels do not match letters on the thermostat, check “Alternate Wiring” on
page 6 and connect to terminal as shown (see notes, below).
WIRE HOLE
LABELED WIRES
R
Remove metal jumper if you have both R and
Rc wires.
INSERT WIRES
AND TIGHTEN
SCREWS
SCREW
G
Y
W
Not
W
Used
We are here to help. Call 18004681502 for wiring assistance.
5
Alternate Wiring
M32734
If labels do not match letters on the thermostat, check the chart below and connect to terminal as shown here (see notes, below).
44
NOT
B O G Y
W
R Rc
USED
If wires will be connected to both R and Rc terminals, remove metal jumper.
Do not use C or X. Wrap bare end of wire with electrical tape.
If you have a heat pump without auxiliary/backup heat connect O or B, not both. If you do not have a heat pump, do not connect B. Wrap bare end of wire with electrical tape.
Place a jumper (piece of wire) between Y and W if you are using a heat pump without auxiliary/backup heat.
7 Install Batteries
Install two AAA alkaline batteries.
Back of thermostat
RTHXXXX
M32707
6
8 Set fan operation switch
M32716
Move the switch to the proper setting: Gas or Oil: For gas or oil heating systems,
leave the fan operation switch in this factory­set position (for systems that control the fan in a call for heat).
Electric or Heat Pump: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.)
9 Install Thermostat
onto Wallplate
Install thermostat onto the wallplate on the wall.
GAS OR OIL
ELECTRIC OR HEAT PUMP
GAS OR OIL
ELECTRIC OR HEAT PUMP
Not
W/
Used
Aux
RTHXXXX
10 Turn Power Back On
Turn the power back on to the heating/cooling system.
Circuit breaker box Heating/cooling system
Fan
Heat Off Cool
Heat Off Cool Auto On
Fan
Auto On
M33588
or
power switch
7
11 If your system type is...
M33589
M33590
If your system type is:
q Single Stage Heat and Cool q Heat Only or Cool Only
Congratulations, you’re done!
If you are not sure of your system type or if you have other questions, call us toll-free at 18004681502.
This thermostat works on single stage 24 volt or 750 mV systems. It will NOT work on multi-stage systems.
Advanced Installation
Enter System Setup
To enter system setup, press and hold both the s and t buttons until the display changes (approximately 5 seconds).
Changing Settings
1. Press the s or t button to change the setting.
2. Press the s and t buttons simultaneously for one second to advance to the next function.
3. When the last function is displayed, press the s and t buttons to save any changes and exit the menu.
Heat Off Cool
5
8
Fan
Auto On
5
Function Setting
NOTE: If you do not press any button for 60 seconds while you are in the setup menu, the thermostat automatically saves any changes made and exits the menu.
Function
5 select your heating system and
14 select Fahrenheit or Celsius
15* select Compressor Protection settings
* Compressor Protection: This feature forces the compressor to wait approximately 5 minutes
before restarting, to prevent equipment damage. During the wait time, the message “Cool On” or “Heat On” is displayed on screen.
Description Press the s or t button to Setting
optimize its operation
temperature display
5 Gas or oil furnace: Use this setting if you have a standard gas or
oil furnace that is less than 90% efficient.
6 Electric furnace: Use this setting if you have any type of electric
heating system.
3 Heat pump, hot water or high-efficiency furnace:
Use this setting if you have a hot water system or a gas furnace of greater than 90% efficiency.
2 Gas/oil steam or gravity system: Use this setting if you
have a steam or gravity heat system.
0 Fahrenheit temperature display (°F) 1 Celsius temperature display (°C)
1 On 0 Off
About your new thermostat
Your new Resideo thermostat has been designed to give you many years of reliable service and easy-to-use, push-button climate control.
Displays ambient (measured) temperature at all times
One-touch access to setpoint temperature
Built-in compressor protection
9