Honeywell Home D6 PRO Installation Manual

D6 PRO SMART
33-00322EFS-03
DUCTLESS CONTROLLER
DC6000WF
Installation Guide
Need Help?
Go to
customer.resideo.com
Call
1-8 0 0- 63 3- 39 91
In this box
Wall plug
USB cable
Tabletop stand
Wall mount hook and loop strips (2)
Controller
The op eration of t his equip ment is subj ect to the fo llowin g two cond itions : (1) this equi pment or dev ice may not c ause har mful inter ferenc e, and (2) this eq uipment or d evice mu st accept a ny interf erence , includin g interfe rence tha t may caus e undesire d operat ion.
Power supply input 120240V, 5060HZ, 0.3 A. Output to control 5V 1000 mA
Resideo Inc., 1985 Douglas Drive North,
www.resideo.com
©2019 Resid eo Technolo gies, In c. This pro duct is man ufactur ed by Resi deo Technol ogies, I nc., Gol den Valley, M N, 1-800-633-3991 The Hon eywell H ome trade mark is us ed under lic ense fro m Honeyw ell Inter national I nc. All ri ghts res erved.
Golden Valley, MN 55422 33-00322EFS—03 M.S. Rev. 11-19 | Printed in United States
Quick reference
Mode icons
Status display
Down button
AUTO
Auto Changeover
WiFi status
Up button
Mode/ Select button
Choose a location
150°
)
(1
)
°
)
Choose a location where the controller’s signal has a clear path to the ductless unit.
Remove the batteries from the remote controller that came with the ductless unit. That way the two controllers won’t send conflicting commands.
r
ü
The controller sends an IR signal from three places. One on each side, left and right, and one from the top.
Consider them when you choose a location.
75
5 0 ft (10 m
0 ft
0 m
30 ft (10 m
2
Tabletop assembly
1
Pull the power cord through the tabletop stand.
2
Plug the power cord into the controller.
3
Connect the tabletop stand to the controller.
Place the controller in your
5
selected location.
Wall mount assembly
1
Plug the power cord into the controller.
4
Plug the power cord into the wall adapter, and plug in the wall adapter.
2
Snap the back plate onto the controller.
3
Attach the wall mount hook and loop strips to the controller, slightly overlapping the back plate on both sides.
Attach the controller to the
5
wall in your selected location.
4
Plug the power cord into the wall adapter, and plug in the wall adapter.
3
System setup
Connect the controller to power. Press any button to enter setup.
1
2
3a
Press
o once. Display should
-1 (Controller Location).
show
Setting Options (Default in bold)
Controller Location 01 – Tabletop
-1
3c
Press
o to select the option for setting -1.
4a
Setting
-2 is displayed. Press o
to access options for setting
Temperature Scale 01 – °F
-2
Press
4c
5a
5c
6a
6c
7a
7c
8a
8c
9
o to select the option for setting -2.
Setting
-3 is displayed. Press o
to access options for setting
Outdoor Unit
-3
Configuration
o to select the option for setting -3.
Press
Setting
-4 is displayed only if
-3 is set to 02 - Multi. Press
setting
o to access options for setting -4.
Multi Outdoor Unit
-4
Number
Press
o to select the option for setting -4.
-5 is displayed. Press o
Setting to access options for setting
Ductless Unit Brand See page 19 for Ductless Unit Brand
-5
Press
o to select the option for setting -5.
-6 is displayed. Press o
Setting to access options for setting
Ductless Unit Model See page 19 for Ductless Unit Model
-6
o to select the option for setting -6.
Press
The screen will display
Setup Complete
3b
Press
until the display shows the
+
desired setting for the controller location.
02 – Wall mount
4b
-2.
02 – °C
5b
-3.
01 – Single
02 – Multi
with the same outdoor unit)
6b
02 - 99 (One D6 per indoor unit. Set a different
number for each D6 when controlling a multi­unit system. This is used for app control.)
7b
-5.
ID
8b
-6.
ID
. Press o to save and exit system setup.
until the display shows the
Press
+
desired setting for the temperature scale.
Press
until the display shows the
+
desired setting for outdoor unit.
(more than one indoor unit used
Press
to define the number of
+
the indoor unit this D6 controls.
until the display shows
Press
+
the desired brand ID.
until the display shows
Press
+
the desired model ID.
Note: If you need to re-enter the set-up menu, press/hold the
4
and o buttons.
+, -
Display sleep
The controller goes into Display sleep (the screen is dim) after 45 seconds of inactivity. Press does not change temperature or settings.
o to wake up the controller. This button push
Change mode
1. Be sure the controller is not in Display sleep, then press the system mode.
2. Stop pressing
The ductless unit will beep when it gets a command from the controller.
Symbol Mode
[screen is
blank]
o when you reach the mode you want.
Heat mode - the ductless unit warms the space to the temperature shown on the controller.
Cool mode - the ductless unit cools the space to the temperature shown on the controller.
Off mode - the ductless unit is turned off
o to change
Change temperature
Warmer Cooler
Room temperature
Any time the controller is not being interacted with, the current room temperature is displayed on screen.
Viewing set temperature
Be sure the controller is not in Display sleep, then press + or - once to view the current set temperature. The set temperature will “pulse” on screen. After a short period of time the screen will change to display the room temperature.
Change temperature
1. Be sure the controller is not in Display sleep, then press + or - more than once to change the set temperature so it is higher or lower in the current mode.
2. Stop pressing
3. The screen will pulse and then return to the room temperature display.
or - when you reach the temperature you want.
+
5
WiFi setup
AUTO
1. Download the Honeywell Home app.
2. Create an account or log in to your account.
3. Select “Add New Device” from the menu in the app.
4. Choose D6 Pro WiFi Ductless Controller.
5. Follow instructions in the app to configure the controller.
Note: During setup, the WiFi icon you the controller status in the WiFi connection process.
Blinking blue Controller is powered up and ready to begin connecting. Solid blue Controller is connected to the mobile device through the app. Solid green Controller is connected to the WiFi network. Solid red Controller is disconnected from the WiFi network. Blinking red Controller is disconnected from WiFi network and has lost it’s
schedule. Reconnect to WiFi network to resume schedule.
In the Honeywell Home app
In the app you can set the controller to Auto Changeover. The controller will switch from heating mode to cooling mode based on the temperature setting and the room temperature.
When in Auto Changeover mode, screen.
will blink or be on solid. This tells
will be displayed on the controller
Enter system setup
You can change your controller settings at any time. To enter system setup:
1. Be sure the controller is not in Display sleep, then press and hold
and o and - for three seconds all at the same time.
+
2. Change the settings as needed. See “System setup” for more
information.
Software and security questions
Q: How can I be sure my D6 controller is running the most up-to-date
firmware?
A: When your D6 controller is connected to WiFi, it will automatically
receive over-the-air firmware updates from Resideo. These firmware updates contain things such as new features as well as security upgrades. Keep your D6 controller connected to WiFi to ensure it receives these updates.
Q: How can I prevent a cybercriminal from making unauthorized changes
to my D6 controller?
A: If a cybercriminal gains access to your WiFi router, they can tamper
with a wide range of online activities, including the settings on your connected devices. Make sure you change the default password on your WiFi router, and when you select a new password, make sure it uses multiple upper- and lower-case letters and special characters.
The product should n ot be dispose d of with other h ousehold wa ste. Check f or the neares t authorize d colle ction cent ers or authorized recyc lers. The c orrect disp osal of end- of-life eq uipment will help preven t potential negative consequences for the environment and human health.
6