Honeywell Home CT30, CT33, CT31 Owner's Manual

CT30 Series
M37781
69-2338EFS-04
Getting started
Owner’s Manual
English: Page 1
Mode d’emploi
Français : Page 6
Manual de Uso
Español: Página 11
Check package contents:
• Thermostat
• Coverplate
Wall anchors & screws (2 each)
Caution card
Wire labels
Remove your old thermostat
TURN OFF POWER at heating/cooling system (or fuse/circuit-breaker panel).
Remove cover and thermostat, but leave wallplate with wires attached.
Leave wallplate in place.
Old thermostat
Cover
Before you begin, make sure you have:
No. 2 Phillips & small pocket screwdrivers
• Hammer
Level (optional)
• Pencil
Drill and bit (3/16” for drywall, 7/32” for plaster)
Is there a sealed tube containing mercury? If so, see mercury notice below.
MERCURY NOTICE
If your old thermostat contains mercury, contact your local waste management authority for proper disposal instructions.
M23786
CT30 Series • Owner's Manual
0
0
0
M23787
Label wires and remove old wallplate
Use a screwdriver to disconnect wires one by one. As you disconnect each wire, wrap it with the label matching the letter on your old thermostat. (Adhesive labels are supplied in your thermostat package.)
Remove the old wallplate only after all wires are labeled. Be careful not to let loose wires fall into the wall opening.
Wrap supplied labels securely around each wire. Do not let wires fall into wall opening!
IGNORE WIRE COLORS: Use only letter designations to identify wire types.
For CT30/CT33: If your old thermostat has 3 or more wires (not counting terminals C or C1), you may have purchased the wrong replacement thermostat. Stop now and call 18004681502 for advice.
Mark mounting position
CT30/CT33 CT31
For CT31: If your old thermostat has 5 or more wires (not counting terminals C or C1), you may have purchased the wrong replacement thermostat. Stop now and call 18004681502 for advice.
1. Pull wires through base (CT31 only).
2. Level base if desired.
3. Mark positions of both screw holes.
69-2338EFS—04 2
English: Page 1 • Français : Page 6 • Español: Página 11
M29583
M29582
Mount thermostat base - CT30/CT33
1. Drill holes at pencil-marked locations (3/16” holes for drywall, 7/32” holes for plaster).
2. Use hammer to tap anchors into holes until flush with wall.
3. Optional: Pull wires through cover plate (if needed to cover marks left by your old thermo­stat).
4. Connect wires first (see page
4), then insert screws. Check level if desired, then tighten screws.
Optional cover plate
Mount thermostat base - CT31
1. Drill holes at pencil-marked locations (3/16” holes for drywall, 7/32” holes for plaster).
2. Use hammer to tap anchors into holes until flush with wall.
3. Optional: Pull wires through cover plate (if needed to cover marks left by your old thermo­stat).
4. Pull wires through thermostat base and insert screws. Check level if desired, then tighten screws.
Optional cover plate
Thermostat base
Thermostat base
3 69-2338EFS—04
CT30 Series • Owner's Manual
M29587A
M29586
M29584
0
Connect wires
1. Match each labeled wire with same letter on terminal.
2. Use a screwdriver to loosen screw terminals, insert bare wires beneath screws, then tighten screws.
3. Push any excess wire back into the wall opening.
Labels don't match?
If labels do not match letters on thermostat, see table below.
Connect to Existing wires CT30/CT33 CT31
R • RH • 5 • V Terminal “R” Terminal “R” W • W1 • H Terminal “W” Terminal “W” Y • Y1 • M [1] Terminal “Y" G • F [1] Terminal “G” Rc [1] [1]
[1] If this wire is present, you may have purchased the
wrong thermostat. Call 18004681502 for help.
CT33 model is for 750 MV heat only
Set adjustment lever (CT30/CT31 only)
1. Separate cover from thermostat, and remove the insert.
2. Use a pencil to move the adjustment lever to the proper setting for your system (see table below).
Your system Setting
Gas or oil furnace (less than 90% efficiency) 0.4 Electric furnace (any type) 0.3 High efficiency furnace (more than 90% efficiency) 0.8 Hot water system 0.8 Gas/oil steam or gravity system 1.2
CT30/CT33
CT31
Finish installation
69-2338EFS—04 4
1. Mount thermostat on base and tighten three mounting screws (CT31 only).
2. Align the 3 tabs on the cover with slots on the thermostat, then push gently until the cover snaps into place.
3. Restore power at the heating/cooling system, or at the fuse/circuit-breaker panel.
Operation
English: Page 1 • Français : Page 6 • Español: Página 11
System off (select models)
Move lever to far left to turn off heating system.
Fan switch (CT31)
Auto: Fan runs only when heating
or cooling system is on.
On: Fan runs continuously.
Temperature setting
Adjust to set desired indoor temperature.
M29588A
System switch (CT31)
Cool: Controls the cooling system.
Heat: Controls the heating system.
Off: All systems are off.
CAUTION: EQUIPMENT DAMAGE HAZARD (CT 31).
Do not operate cooling system when outdoor temperature is below 50°F (10°C).
1-year limited warranty
Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) year from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or (ii) call Resideo Customer Care at 18004681502. Cus­tomer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the product was in the possession of a consumer. Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, IN CLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
5 69-2338EFS—04
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURA TION OF THIS WARRANTY. Some states do not allow limita­tions on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 18004681502.
Loading...