Honeywell TBE PRODUCT DATA

<
FIXED ORIFICE, FLARE CONNECTIONS
TBEX 0.5 - 4.5 two-way
TBEX 0.5 - 4.5 angle
Application
Thermostatic expansion valves series TBE are used in plants with one or more refrigerant circuits, especially for series installations mobile air-conditioning and cooling units with flare connection, e. g. bus AC, train AC, transport cooling.
Materials
Body
Thermal head
Connections
brass
stainless steel
brass
Series TBE
THERMOSTATIC EXPANSION VALVES
PRODUCT DATA
Features
TBE: with internal pressure equalisation; for single
injection in installations with one or more cooling circuits.
TBEX: with external pressure equalisation; for optimal
evaporation effectiveness in all applications. Obligatory for multiple injection by liquid distributors.
Combi adsorber charge as standard
The same valve can be used for different
refrigerants (see table on page 2)
Controller charge is high sensitive and responsive
thus lowest possible level of superheat can be achieved
Charge is not sensitive to effects of temperature on
the capillary tube and valve head
damping characteristic results in stable control
behaviour
Optional available with gas charge and MOP
Adjustable superheat for two-way construction
Fixed superheat setting for angle construction
Warm thermal head provides best reliability
Flare connections
Extreme durable due to stainless steel head and
stainless steel diaphragm welded using protective gas
Fixed orifice
Refrigerants: R134a, R401A, R12
R22, R407C, R407A, R422D R404A, R507A, R402A, R407B, R502 Further refrigerants on request.
Specification
Nominal capacity range
Evaporating temperature range
Maximum pressure PS Maximum test pressure PF Max. ambient temperature Max. bulb temperature Static superheat Length of capillary tube Bulb diameter
0.99 to 17.0 kW R22 (small orifice graduation for optimal control behaviour)
see table on page 2 see table on page 2 see table on page 2 100 °C 140 °C approx. 3 K
1.5 m 12 mm
Copyright © 2009 Honeywell GmbH • Subject to change without notice EN0H-1906GE23 R0709
SERIES TBE
Thermal Charges and Temperature Ranges
1. Adsorber charge
Refrigerant
R134a, R401A, R12
R22, R407C, R407A, R422D
R404A, R507A, R402A, R407B, R502
Further refrigerants on request.
Thermal systems with adsorber charge are completely insensitive to effects of temperature on the capillary tube and valve head. It reacts only according to the temperature of the bulb.
Thus, Honeywell TBE(X) valves with combi adsorber charge work absolutely reliable, even in icy condition or while defrosting using hot gas.
2. Adsorber charge with pressure limiting performance (MOP)
Refri­gerant
R134a, R401A, R12
R22, R407C, R407A, R422D
R404A, R507A, R402A, R407B, R502
Further refrigerants and MOP on request
Evaporation temperature range
+5 °C to -30 °C MOP A +15 °C 34 37.4
-10 °C to -30 °C MOP A ±0 °C 29 31.9
+5 °C to -45 °C MOP A +15 °C 36 39.6
-10 °C to -45 °C MOP A ±0 °C 29 31.9
-27 °C to -45 °C MOP A -18 °C 29 31.9
-10 °C to -50 °C MOP A ±0 °C 36 39.6
-20 °C to -50 °C MOP A -10 °C 34 37.4
-27 °C to -50 °C MOP A -18 °C 34 37.4
Evaporation temperature range
+15 °C to -30 °C 34 37.4
+15 °C to -45 °C 36 39.6
±0 °C to -50 °C 36 39.6
MOP PS
PS
(bar(a))
(bar(a))
PF
(bar(a))
PF
(bar(a))
Capacities
3. Gas charge
Refrigerants and MOP on request. With gas charged valves and MOP it is under all operating
conditions necessary that the bulb is always colder than the capillary tube and the thermal head!
With the Honeywell TBE series the thermal head is heated advantageously by the liquid refrigerant. The warm thermal head is on the safe side at any time.
Type Orifice size
0.5 0.69 0.99 0.95 0.67 0.68 0.69
0.7 1.0 1.4 1.3 0.92 0.97 0.98
1.0 1.4 2.0 1.9 1.3 1.4 1.4
TBE
TBEX
* Capacities are based on t0 = +4 °C, tc = +38 °C and 1 K subcooled liquid refrigerant entering the valve.
For other operating conditions see capacity charts in Honeywell catalogue or consult the Honeywell software.
EN0H-1906GE23 R0709 2 Honeywell GmbH • Subject to change without notice
1.5 2.2 3.2 3.1 2.2 2.2 2.3
2.0 2.9 4.0 3.9 2.7 2.8 2.9
2.5 4.0 5.8 5.6 3.9 4.1 4.1
3.0 6.6 9.3 8.9 6.3 6.5 6.6
3.5 8.7 12.2 11.7 8.3 8.6 8.7
4.5 11.8 17.0 16.4 11.3 12.0 12.1
R134a R22 R407C R422D R404A R507A
Nominal capacity (kW)*