Honeywell
T6380, T8380 SERIES
Electronic Fan Coil Thermostats
The Um and T8380 Series
of electronic Ian coil ihcrmoslals
provide precision ON-OFF control
of fan-forced heating, ventilating
and air conditioning equipment.
There are models for
cooling-only, heating-only, and
heating-cooling fan coil systems
with manual or remote heat-cool
changeover.
llydronic Ian coil systems may
be four- or two-pipe configuration
iitted with zone or VC Series valves.
f-an control options include
constant, cycled, or user selectable
“ON-.UTO” operation. Manual Ian
speed selection is standard. .Ml
models can turn the system off.
✓ Electronic tcmpcraiurc sensing provides energy-
elTiciem. precision operation for imixiinum comfort.
✓ Adjustment ranges 55® to 90®F or 13® lo 32®C.
✓ Optional scalcpiatc nxarked "Cool Warm" available.
✓ Easy-to-use set point knob.
✓ LED system status indicator.
✓ Contemporary white sculpted styling.
✓ Rugged molded iheniioplaslic housing with
captive mounting screws, mounts on single-gang
NEMA-siandard (U.S.) electrical box.
✓ Optional range stops and cover locking kit available.
✓ Vertical or horizontal mounting configurations.
✓ .Available for line or low-voltage control.
✓ Suitable for electric heat and inductive loads such as
valves, relays, contactors, compressors, and fans.
^ Screw terminal block wiring.
^ Three level fan speed selection.
^ System OFF disconnects all connected loads.
Electronic Fan Coil Thermostats
Specifications
ELECTRICAL RATINGS;
Señes -
Power Supply; 110-130 or 208-277 Vac 50-60Hz.
T638L T6387 Output Rating, cyd&l (“Auto’^’) fan control
50-60 Hz
Full Load Amps* 3.8 2.1 1.9 1.6
Locked Rotor A 22.8 12.6
Hlot DUTY 125 VA
' Equivalent to NEMA 1/8 horsepower rating for a hermeicallysealed motor such as a compressor. Allowable connected load
mu$l be determined by adding nameplate full load and
locked rotor (Inrush) ratings of all loads.
T63S3 Output Rating, constant fan operation
Thermostai (Heat and Cool
50-60 Hz 120 V
Full Load Amps** 3.8
Locked Rotor A
Pilot DUTY
Resistive {heat only) 10.0 N/At
Fan (Air Handler)
50-60 Hz
Full Load Amps** 3.8 2.1 1.9 1.6
Locked Rotor A 22.8 12.6
Equivalent to N£MA 1/4 horsepower rating for a hermetically-
sealed motor. Allowable load must be determined from fan name
plate ratinge.
t North American national electrical codes require all ungrounded
(live) conductoro to cicctrio rcoiotanoc heating to bo OroKon at tho
thermostat OFF setting. The T6380 has a single line break.
The 230 V rating is site-approvable in Canada on 416 V 4-wlre Wye
distribution systems. The non-induclive rating for 230 V “a.c. mains'*
with one ungrounded conductor is 6.0 A.
120 V
22.8 12.6 11.4 9.5
120 V
208V
outputs)
208V 230 V 277 V
2.1 1.9 1.6
208V
125 VA
230 V 277 V
114
N/At
230 V 277 V
11.4
9.5
5.6
9.5
Models - Order Specifications
Fan Coil System
2-pipe
• Cooling only Constant T6383A
• Heating Only Constant T6383A T6383A
2-pipe Heat-Coo)
♦ Manual
Char»ge/0\^r
• Seasonal Auto C/0 Constant T0383A T6383A T8383A
♦Seasonal Auto C/0
with Aux Electric Ht.
4-pipe Heat-Cool
• Manual C/0 Constant T6383B
3-Speed
Fan
Cycled T6381A T6381A T8381A
On-Aulo T6387A T6387A T8387A
Cyded T6381A T6381A
On-Auto
Constant T6383B ТБ383В T8383B
Cycled T6381B T6381B T8381B
Cycled T6381A
On-Auto
Constant T6383B T6383B T8383B
Cycled Т63Б1В T6381B T8381B
Cycled T6381B
120V 208-277V 24V
T6383A T8383A
ТбЗе7А T6367A T&387A
T6381A T8381A
T6387A
T6387A T8387A
T6383B T8383B
T6381B T8381B
T8380 Series -
Power Supply; 20-30 Vae, 50-60 Hz, Class 2.
Output Rating: 100 VA pilot duty.
CONTROL RANGE;
55 to 90®F, J3 to 32®C, marked in P increments.
System L.E.D. illuminates on call for heating or eooling.
OPERATING RANGE:
-22 to +104^F (-30 to + 40^C), 5 to 95% RH,
non-condensing.
PERFORMANCE SPECIFICATIONS:
Precision; ± 1®F temperature swing (0.9^C differential)
Accuracy: (PC) droop with 4 A toad.
DIMENSIONS; See Fig. 1 - Nominal Dimensions.
MOUNTING:
Direct mounting on single gang NEMA 2” x 3”
flush-mount or 2’’ x 4’^ surface mount electrical box,
or on 4” X 4” box with mud ring.
Dress covers avai.able for vertieal or horizontal mount.
COMPATIBILITY:
T6380 series is compatible with V4043, V4044 Zone
Valves and VC40-series Balanced Hydronic Valves.
T6383A is also compatible with VC60-scries, 3-wire
valve in cooling-only and heating-only applications.
T8380 scries compatible with V8043, V8044 and
VC80-sei ies valves.
WIRING CONNECTIONS:
Screw teiminal block suitable for 1-14 AWG, 2-18
AWG, or 1-1.5 mm^ copper wire.
APPROVALS:
Canadian Standards Association Certified LR1322
Underwriters Laboratories Listed File No. E47434.
ACCESSORIES
272380 range stop/cover locking kit.
272827 - T6380 replacement cover with Cool-Warm scale.
272828 - T8380 replacement cover with Cool-Warm scale.
Fig. 1 - Nominal Dimensions in inches and mm.
T8383A
T8381A
Home and Building Control
In the tl.S.A.
1985 Douglas Dr. North
Golden Valley, MN 55422
A14S4 4/9$
Honeywell
Hefpmg You Contro/ Your World
In Canada
740 Ellesmere Road
Scarborough, ON MlP 2V9