Refrigeration Controllers
T4031A; T6031A Refrigeration Temperature Controller
Provide limit or temperature control in refrigerated areas where remote mounting of sensing element is required.
• Liquid-filled copper elements provide rapid sensing to control the compressor system
• Control temperature in a duct, tank, freezer or cooler
• Controller element can be directly immersed in the controlled medium
• Adjustable control setpoint
• Ambient temperature compensation provides good temperature control
• Refer to T775 Electronic Remote Temperature Controller where more exact control is required and/or remote controller location is preferred
Dimensions in inches (millimeters) |
|
|
Type: Remote bu b |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Dimensions, Approximate: 5 5/8 in. high x 2 in. wide x 2 1/4 in. deep |
|
|
|
|
|
|
|
|
|
|
|
|
(143 mm high x 51 mm wide x 57 mm deep) |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
Maximum Operating Temperature: 125 F (52 C) |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
Voltage: 120 Vac; 240 Vac |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Switching: 1 SPDT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sensor Element: Copper bulb |
|
|
|
|
|
|
|
|
|
|
|
|
Bulb Size: 3/8 in. diameter x 3 in. long (10 mm diameter x 76 mm long) |
|
|
|
|
|
|
|
|
|
|
|
|
Contact Ratings (120 Vac): 8.0 AFL, 48.0 ALR |
|
|
|
|
|
|
|
|
|
|
|
|
Contact Ratings (240 Vac): 5.1 AFL, 30.6 ALR |
|
|
|
|
|
|
|
|
|
|
|
|
Approvals |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Canadian Standards Association: Certified: File No. LR95329-1 |
|
|
|
|
|
|
|
|
|
|
|
|
Underwriters Laboratories, Inc: File: SA481, Guide: SDFY |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Capillary Length |
Differential Temperature |
Setting Temperature Range |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
Product Number |
Application |
(ft) |
(m) |
(F) |
|
(C) |
(F) |
(C) |
Comments |
|
|
|
|
|
|
|
|
|
|
|
|
T4031A1073/U |
Provides control of cooled |
8 ft |
2.44 m |
3.5 |
F |
— |
-30 F to +50 F |
— |
— |
|
|
or refrigerated space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T6031A1011/U |
Provides control of cooled |
5 ft |
1.5 m |
3.5 |
F to 16 F |
— |
15 F to 90 F |
— |
— |
|
|
or refrigerated space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• |
T6031A1029/U |
Provides control of cooled |
8 ft |
2.4 m |
3.5 |
F to 16 F |
— |
-30 F to +90 F |
— |
— |
|
|
or refrigerated space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T6031A1052/U |
Provides control of cooled |
5 ft |
1.5 m |
3.5 |
F to 16 F |
— |
-30 F to +90 F |
— |
— |
|
|
or refrigerated space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T6031A1060/U |
Provides control of cooled |
20 ft |
6.1 m |
3.5 |
F to 16 F |
— |
-30 F to +90 F |
— |
— |
|
|
or refrigerated space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T6031A1086/U |
Provides control of cooled |
8 ft |
2.4 m |
— |
|
1.9 C to 8.9 C |
— |
-35 C to +30 C |
Celsius model |
|
|
or refrigerated space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T6031A1136/U |
Provides control of cooled |
8 ft |
2.4 m |
3.5 |
F to 16 F |
— |
-30 F to +90 F |
— |
— |
|
|
or refrigerated space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* TRADELINE models • SUPER TRADELINE models
340 |
customer.honeywell.com |
70-6910 |