Installer Programming mode User Programming mode
Master User Programming
mode
GKP advanced functionalities
Version V1.0
Author: Florent Busnoult, EMEA Residential Sales Support EMEA, HSF
Date: 15/11/2016

© 2015 by Honeywell International Inc. All rights reserved.
9
Recap’
1
Installer
Procedure Sucrebox Domonial
Associate a TAG to a
user

© 2015 by Honeywell International Inc. All rights reserved.
9
Recap’
1
Master User
Here
User
Procedure Sucrebox Domonial

© 2015 by Honeywell International Inc. All rights reserved.
9
Set arming with identification
1
3 - Press “Total arming” button to select function
4 - Press to activate arming with identification (code and TAG)
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234
All Status LEDs start flashing and a long beep is played
5 - Press (⑤ to exit programming and save your changes
All LEDs stop flashing and a double beep is played

© 2015 by Honeywell International Inc. All rights reserved.
9
Set quick arming (no identification needed)
1
3 - Press “Total arming” button to select function
4 - Press to activate quick arming
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234
All Status LEDs start flashing and a long beep is played
5 - Press (⑤ to exit programming and save your changes
All LEDs stop flashing and a double beep is played

© 2015 by Honeywell International Inc. All rights reserved.
9
Associate a TAG to a user
1
3 - Press “0 to 9” button to select user’s number
4 - Present the TAG to the tag reader
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234
All Status LEDs start flashing and a long beep is played
5 - Press (⑤ to exit programming and save your changes
All LEDs stop flashing and a double beep is played

© 2015 by Honeywell International Inc. All rights reserved.
9
Change a user’s code
1
3 - Press “0 to 9” button to select user’s number
4 - Enter new user’s code (4 or 6 digits)
5 - Re-enter new user’s code
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234
All Status LEDs start flashing and a long beep is played
6 - Press (⑤ to exit programming and save your changes
All LEDs stop flashing and a double beep is played

© 2015 by Honeywell International Inc. All rights reserved.
9
Disable a user’s code (disable the code for a user and keep the
TAG only)
1
3 - Press “0 to 9” button to select user’s number
4 - Enter 0000 (or 000000 if 6 digits)
5 - Press
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234
All Status LEDs start flashing and a long beep is played
6 - Press (⑤ to exit programming and save your changes
All LEDs stop flashing and a double beep is played

© 2015 by Honeywell International Inc. All rights reserved.
9
Disable a user
1
3 - Press “0 to 9” button to select user’s number
4 - Press to disable the user (code and TAG)
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234
All Status LEDs start flashing and a long beep is played
5 - Press (⑤ to exit programming and save your changes
All LEDs stop flashing and a double beep is played

© 2015 by Honeywell International Inc. All rights reserved.
9
Enable a user
1
3 - Press “0 to 9” button to select user’s number
4 - Press to enable the user (code and TAG)
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234
All Status LEDs start flashing and a long beep is played
5 - Press (⑤ to exit programming and save your changes
All LEDs stop flashing and a double beep is played

© 2015 by Honeywell International Inc. All rights reserved.
9
Adjust beep volume
1
1 - Press and hold the and keys simultaneously more than 2
seconds to enter user programming mode.
A double beep is played and all LED light on.
2 - Keep pressing the key to select the device that you wish to adjust
(each device will emit a beep when it is selected).
Example: If you want to adjust the beep level for device 2: press the
key twice. Device 2 will emit a beep to confirm its selection.
All LEDs start flashing.
3 - Press a key from to to select the required beep volume (1 =
min, 7 = max).
The device selected will emit a beep at the new level to confirm
the beep volume.
4 - Press the key to exit user programming mode and save you
changes.
5 - After a few seconds, a double beep is played and all LED stop flashing.
User
Programming mode

© 2015 by Honeywell International Inc. All rights reserved.
9
To enable/disable chime
1
1 - Press and hold the and keys simultaneously more than 2
seconds to enter user programming mode.
A double beep is played and all LED light on.
2 - Press the key.
A double beep is played and all status LEDs start flashing.
3 - Press the key to enable the chime or the key to disable the
chime.
A long beep is played.
4 - Press the key to exit user programming mode and save you
changes.
5 - After a few seconds, a double beep is played and all LED stop flashing.
User
Programming mode

© 2015 by Honeywell International Inc. All rights reserved.
9
To associate a TAG to a user
1
1 - Press and hold the user number “0 to 9” key for 3 seconds (1 is the
master).
A double beep is played and all LEDs light on.
2 - Enter the master code or present the master tag.
A beep is played and all status LEDs start flashing.
3 - Present a new TAG.
The programming mode ends automatically.
4 - After a few seconds, a double beep is played and all status LED stop
flashing.
The operation fails if the TAG is already registered.
If the user already has a TAG, the new one will take its place.
Master User
Programming mode

© 2015 by Honeywell International Inc. All rights reserved.
9
To change a user’s code
1
1 - Press and hold the user number “0 to 9” key for 3 seconds (1 is the
master).
A double beep is played and all LEDs light on.
2 - Enter the master code or present the master tag.
A high beep is played and all status LEDs start flashing.
3 - Enter the code for the new user. A high beep is played.
4 - Re-enter new user’s code. A high beep is played.
The programming mode ends automatically.
5 - After a few seconds, a double beep is played and all status LED stop
flashing.
Master User
Programming mode

© 2015 by Honeywell International Inc. All rights reserved.
9
To disable a user’s code
1
To disable a user’s code and keep the TAG only:
1 - Press and hold the user number “0 to 9” key for 3 seconds (1 is the
master).
A double beep is played and all LEDs light on.
2 - Enter the master code or present the master tag.
A high beep is played and all status LEDs start flashing.
3 - Change the code to 0000 (or 000000 if 6 digits).
4 - Re-enter the code 0000 (or 000000 if 6 digits).
A high beep is played.
5 - After a few seconds, a double beep is played and all status LED stop
flashing.
Master User
Programming mode

© 2015 by Honeywell International Inc. All rights reserved.
9
To disable a user
1
1 - Press and hold user number “0 to 9” key for 3 seconds.
Note: it is not possible to disable the master user.
A double beep is played and all status LEDs light on.
2 - Enter the master code or present the master tag.
A high beep is played and all status LEDs start flashing.
3 - Press the key to disable the user.
The programming mode ends automatically.
4 - After a few seconds, a double beep is played and all status LED stop
flashing.
Master User
Programming mode

© 2015 by Honeywell International Inc. All rights reserved.
9
To enable a user
1
1 - Press and hold user number “0 to 9” key for 3 seconds.
A double beep is played and all status LEDs light on.
2 - Enter the master code or present the master tag.
A high beep is played and all status LEDs start flashing.
3 - Press the key to disable the user.
The programming mode ends automatically.
4 - After a few seconds, a double beep is played and all status LED stop
flashing.
Master User
Programming mode