Honeywell GKP User Manual

Installer Programming mode User Programming mode
Master User Programming
mode
GKP advanced functionalities
Version V1.0
Author: Florent Busnoult, EMEA Residential Sales Support EMEA, HSF
Date: 15/11/2016
9
Recap
1
Installer
Procedure Sucrebox Domonial
Step by step guide
Set
arming with
identification
Here
Set quick
arming
Here
Associate a TAG to a
user
Here
Change a user’s code
Here
Disable a user’s code
Here
Disable a user
Here
Enable a user
Here
9
Recap
1
Master User
Adjust beep volume
Here
Enable Chime
Here
Disable Chime
Here
Assign TAG
Here
Changing Code
Here
Disabling Code
Here
Enable user
Here
Disable user
Here
User
Procedure Sucrebox Domonial
Step by step guide
9
Set arming with identification
1
3 - Press “Total arming” button to select function
4 - Press to activate arming with identification (code and TAG)
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234 All Status LEDs start flashing and a long beep is played
5 - Press ( to exit programming and save your changes
All LEDs stop flashing and a double beep is played
9
Set quick arming (no identification needed)
1
3 - Press “Total arming” button to select function
4 - Press to activate quick arming
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234 All Status LEDs start flashing and a long beep is played
5 - Press ( to exit programming and save your changes
All LEDs stop flashing and a double beep is played
9
Associate a TAG to a user
1
3 - Press “0 to 9” button to select users number
4 - Present the TAG to the tag reader
Installer Programming mode
Enter the installer programming mode
1 - Press simultaneously the two buttons “1” and “3” more than 2
seconds and release them.
A double beep is played and all Status LEDs light up.
2 - Enter installer’s code. On sucrebox: 001234 All Status LEDs start flashing and a long beep is played
5 - Press ( to exit programming and save your changes
All LEDs stop flashing and a double beep is played
Loading...
+ 11 hidden pages