Thank you for purchasing this alarm which is designed to detect the presence of Carbon Monoxide. This manual contains information on the installation and operation of the Carbon Monoxide alarm.
approximately 1 minute intervals to indicate that the unit is operating correctly. This will change to a yellow ash synchronised with chirp if a fault arises. The red alarm light will ash continuously and the buzzer will sound if Carbon Monoxide is present.
The unit is suitable for use in areas where cooking and heating appliances burn fuels such as wood, charcoal, coal, coke, oil, petrol, gas, etc.
Carbon Monoxide (CO) is a highly poisonous gas which is released when fuels are burnt. It is invisible, has no smell and
is therefore very difcult to detect with the human senses. The rst warning symptoms that CO is present in the air are usually
headaches and nausea. Under normal operating conditions, in a room where fuel-burning appliances are well maintained and correctly ventilated, the amount of Carbon Monoxide released into the room by the appliances is not dangerous. A dangerous quantity of Carbon Monoxide can occur if one or more of the following conditions exists:
1. An appliance is faulty or is badly maintained.
2. A ue is partially or totally blocked.
3. A room is not adequately ventilated.
INTRODUCTION
Red Alarm
Test
Light
Button
WHAT IS CARBON MONOXIDE
Status Light: Green = Ok Yellow = Fault
Buzzer
Gas Inlet
CAREFULLY READ AND UNDERSTAND THE CONTENTS
OF THIS INSTRUCTION MANUAL BEFORE USING THE
ALARM. RETAIN THE MANUAL IN A SAFE PLACE FOR
PAY PARTICULAR ATTENTION TO THE SAFETY
WARNINGS. PASS THE MANUAL ONTO ANY
FUTURE REFERENCE.
SUBSEQUENT USERS OF THE ALARM.
WARNING
THIS CARBON MONOXIDE ALARM MAY NOT PROTECT
PEOPLE WHO ARE AT SPECIAL RISK FROM CARBON
MONOXIDE EXPOSURE BY REASON OF AGE,
PREGNANCY OR MEDICAL CONDITION. IF IN DOUBT,
CONSULT YOUR MEDICAL PRACTITIONER.
This Carbon Monoxide Alarm is NOT:
• A substitute for either a smoke alarm or a combustible gas detector.
• To be seen as a substitute for the proper servicing of fuel-burning appliances or the sweeping of chimneys
• To be used on an intermittent basis, or as a portable detector for the spillage of combustion products from fuel-burning appliances or chimneys.
CAUTION
This Carbon Monoxide alarm is designed for indoor use only. Do not expose to rain or moisture. Do not knock or
drop the unit. Do not open or tamper with the unit as this
The alarm will not protect against the risk of Carbon
Monoxide poisoning when the battery has drained.
could cause malfunction.
IMPORTANT
• Carbon Monoxide is produced by the incomplete combustion of fuels such as wood, charcoal, coal, heating oil, paraffin, petrol, natural gas, propane, butane etc.
• Ideally, it is recommended that a Carbon Monoxide alarm should be installed in or near to every room that has a fuel burning appliance such as any gas res, central heating boiler, room heaters, water heaters, cookers, grills, etc.
• This alarm should only be installed by a competent person.
• Ensure that the audible alarm can be heard by all those who
are intended to hear it.
• This product should not be used if any fault signals are given.
• Seek medical help if it is suspected that a member of the household is suffering from Carbon Monoxide poisoning.
• If further details are required which do not appear in this manual, contact Honeywell.
This pack contains: One unit
  Onexingkit
One instruction manual
EFFECTS OF CARBON MONOXIDE POISONING
Carbon Monoxide binds to the haemoglobin in the blood and reduces the amount of oxygen being circulated in the body.
200ppm Slight headaches, tiredness, dizziness, nausea after
2-3 hours.
400ppm Frontal headache within 1-2 hours, life threatening after 3 hours.
800ppm Dizziness, nausea and convulsions within 45 minutes. Unconsciousness with 2 hours. Death within 2-3 hours.
1600ppm Headache, dizziness and nausea within 20 minutes.
Death within 1 hour.
6400ppm Headache, dizziness and nausea within 1-2 minutes. Death within 10-15 minutes.
POSITIONING THE ALARM
1. Units located in the same room as a fuel-burning appliance
• If the unit is located on the wall it should be located at a height greater than the height of any door or window but at least 150mm from the ceiling. If the unit is mounted on the ceiling it should be at least 300mm from any wall.
• The unit should be at a distance of between 1m and 3m from the potential source.
• If there is a partition in a room, the unit should be located on the same side of the partition as the potential source.
• In rooms with sloped ceilings, the unit should be located at the high side of the room.
2. Units located in sleeping rooms and in rooms remote from a fuel burning appliance
• Units should be located relatively close to the breathing area of the occupants.
WHERE NOT TO PUT THE ALARM
Do not place the unit in the following areas:
• Outside the building.
• In or below a cupboard.
• In a damp or highly humid area e.g. a bathroom.
• Directly above a sink or cooker.
• Next to a door or window or anywhere that would be
affected draughts, eg, extractor fan or air vent.
• Where the air ow to the unit would be obstructed by curtains or furniture.
• Where dirt or dust could collect and block the sensor, and stop it working.
• In an area where the temperature could drop below -10˚C or rise to above 40˚C.
• Where it could be easily knocked, damaged, or where it
could be inadvertently removed.
• Do not paint the unit or allow the CO gas inlets to become blocked by dirt, grease or other substances.
IN WHICH ROOM TO PUT THE ALARM
Ideally, an alarm should be fitted in every room that contains a fuel-burning appliance. However, if there is more than one appliance and the number of units is limited, the following points should be taken into consideration when deciding on the best location:
• If there is an appliance in a room where people sleep, a unit should be placed in that room.
• A unit should be located in a room containing a flueless or open-flued appliance.
• If there is an appliance in a room which people use a lot, such as a sitting room, a unit should be placed in that room.
• In a bedsit, the unit should be placed as far away from the cooking appliance as possible but near to where the person sleeps.
• If the appliance is in a room not normally used, such as a boiler room, the unit should be placed just outside the room so that the alarm will be heard more easily.
INSTALLING THE ALARM
The unit can either be free-standing or wall mounted, using the fixings provided.
WALL MOUNTING INSTALLATION
Find a position to install the unit (see “where to put the alarm” and “where not to put the alarm”).
Mounting Pad
Option 1 Special Mounting Pad with Fixing Pin (supplied)
Place the fixing pin through the mounting pad. Using a hammer, gently knock the fixing pin into the wall ensuring that the mounting pad is not hammered too firmly into the wall.
Option 2 Screw and wall plug
Wall
Rawplug
Fixing Pin
TM
5mm
(NOT supplied)
If the wall is too hard to use the fixing
Screw
Wall
pin, use a No. 4 round head screw and Rawplug
TM
.
Once activated and tested (see “using the alarm”), the unit can be hung on the protruding fixing pin using one of the ‘keyholes’ indicated on the back of the unit by the lines shown.
USING THE ALARM
To activate the unit, pull out the activation strip at the side of the
unit. The green and red lights will flash briefly and the buzzer will
sound a short chirp.
Press the test button and hold for up to 5 seconds and check that the red light flashes and the buzzer sounds.
The unit is now operating and is ready for use.
Pull out Strip
to Activate
TESTING YOUR CARBON MONOXIDE ALARM
The unit should be tested once a month by pressing and holding
the test button on the front of the unit for 5 seconds, this tests
the electrochemical cell, electronics and audible alarm. If the unit is functioning correctly, the green light will stay illuminated, the
red light will ash and the alarm will sound. In case of a fault the
unit is giving visual and audible signals once per minute. These signals can be triggered any time by pressing the test button.
SPECIFICATION
Model: H450EN
Gas Detected: Carbon Monoxide
Detection Principle: Electro-chemical cell
Alarm Indication: Flashing red light and audible alarm
Alarm Levels: 50ppm Between 60 to 90 mins
100ppm Between 10 to 40 mins 300ppm Less than 3 mins
Operating Temperature: -10˚C to 40˚C
Humidity Range: 30 to 90% RH non-condensing
Warm-up time after initial switch on: Instantaneous
Normal Operating Life: Up to 7 years
Battery life when in alarm: At least 5 days
Dimensions: 110mm x 76mm x 34mm
Weight: Approximately 110g
CARE AND MAINTENANCE OF ALARM
The Carbon Monoxide alarm is pre-calibrated at the factory and requires no maintenance other than to clean the outside case occasionally with a clean tissue. Ensure that the holes on the front of the unit are not blocked with dust or dirt. DO NOT USE CLEANING AGENTS, BLEACH OR POLISH.
END OF UNIT LIFE
The unit will operate for up to 7 years under normal use. The unit must be replaced when a low battery warning (1 chirp per minute or a fault warning signal (2 chirps per minute and
the status light ashing yellow) is given. It is recommended to
replace the unit after the date marked on the front of the unit.
DISPOSAL
When the unit has come to the end of its life, dispose of it in accordance with local regulations.
BATTERY DIRECTIVE STATEMENT
For safety reasons the H450EN is a sealed unit
and the battery is not replaceable. At the end of the unit’s life, if you have any concerns over the safe disposal of the unit/battery, please contact your local recycling centre or the Honeywell helpline printed in this manual.
OPERATION OF THE ALARM
Normal Operation
When no Carbon Monoxide is present, the status light will ash green approximately
once every minute.
During normal operation the unit carries out a self-check test every 5 minutes.
Alarm Condition When the unit detects Carbon Monoxide, it will give the alarm signal continuously. The
red alarm light will ash and the buzzer will sound approximately 5 chirps per second.
When the unit has been in alarm for 30 minutes the full alarm signal will be given once every minute.
Alarm Signal
The Carbon Monoxide alarm can be distinguished from smoke detector alarms as it
signals C.O. in morse code (approximately 5 chirps per second).
Hush Feature
If required, the audible alarm can be silenced for 5 minutes by pushing the button marked ‘Test’. The red alarm light will continue to ash 5 times per second.
If Carbon Monoxide is still present after the 5 minute hush period, the audible alarm
will sound.
NOTE: The hush facility will not operate at levels above 350ppm Carbon Monoxide. At levels below 350ppm the hush facility will only operate once, ie the audible alarm can only be silenced for one 5 minute period.
Return to Normal Operation
When the Carbon Monoxide gas disperses, the alarm signal will stop. The status light
will ash green approximately once every minute again.
Fault Warning
If a fault is detected the buzzer will sound 2 short chirps every minute. The unit must
then be replaced.
Battery Fault Warning/End of Battery Life
The buzzer will sound 1 short chirp every minute.
NOTE: With normal use the batteries will last for up to 7 years. However, battery life will be reduced if either a fault occurs with the battery or the unit remains in alarm for long periods of time. Should the Battery Fault Warning occur please contact your supplier.
GAS EMERGENCY SERVICE
WHAT TO DO WHEN THE ALARM SOUNDS
If the unit raises an alarm, proceed as follows:
• Open all doors and windows to ventilate the area and allow the Carbon Monoxide to disperse.
• Where possible turn off all fuelled appliances and stop using them.
• Evacuate the property leaving the doors and windows open.
• Ring the gas or other fuel supplier on their emergency
number and explain the problem. Keep the telephone number in a prominent place.
• Do not re-enter the property until the alarm has stopped.
• Get medical help immediately for anyone suffering from the
effects of Carbon Monoxide poisoning such as headaches, nausea, etc. and advise that Carbon Monoxide poisoning is suspected.
• Do not use the fuel burning appliances again until they have been checked and cleared for use by a competent person according to national regulations.
Contact Numbers for OTHER FUEL Appliances:
OIL USERS: Contact OFTEC on 0845 658 5080 SOLID FUEL USERS: Contact HETAS on 0800 600 000
(Please note these numbers are only
available during normal ofce hours)
Gas appliances should be checked for safety annually by a
Gas Safe registered engineer. To nd a registered engineer in your area call Gas Safe Register on 0800 408 5500 or look on
the website: www.gassaferegister.co.uk.
User Manual also available in Braille. A Carbon Monoxide safety information sheet is available in: Punjabi; Urdu; Bengali; Gujarati and Hindi. For copies please call Honeywell Analytics on: 01202 645577
This product complies with European Directives
for Low voltage 2006/95/EC and Electromagnetic
Compatibility 2004/108/EC. The manufacturers full Declaration of Conformity may be found at the following website address: www.honeywellanalytics.com
Status
Light
Red
Alarm
Buzzer
Light
Green
5 chirps per
5 chirps per
per minute
5 chirps per
Green
2 chirps per
minute and
Yellow
Yellow
yellow ash
1 chirp per minute and
yellow ash
TELEPHONE NUMBER
0800 111 999
DECLARATION OF CONFORMITY
1 green
ash per
minute
1 second
1 second
5 ashes
per 1 sec-
ond
1 second
1 green
ash per
minute
KM 565387
BS EN 50291:2001
DISCLAIMER
This Carbon Monoxide alarm is designed to alert you to a potentially dangerous build-up of Carbon Monoxide gas. It is not designed to remedy a Carbon Monoxide problem nor to locate
a specic source of Carbon Monoxide. Honeywell shall not be
liable to pay for any Carbon Monoxide investigation or service call carried out or arranged in response to an alarm.
GUARANTEE
We guarantee your new Carbon Monoxide alarm for six years
from the date of purchase or until the expiry date on the front of
the unit, whichever occurs rst - under normal use and service,
to be free from defects in materials and workmanship.
During this period we will, at our discretion, repair or replace
any part of the Carbon Monoxide alarm which is found to be
defective in either materials or workmanship providing this
occurs under normal use and service. We shall, however, be
under no obligation to repair, or replace units which are found to
be defective in any way due to damage, neglect, unreasonable
use or which have been tampered with or found to have been
dismantled. Should a problem arise with your detector, please
contact your supplier. If you have further problems, please
contact Honeywell Analytics helpline direct on
+44 (0) 1202 645577. If units need to be returned, send them in
suitable packaging along with proof of purchase to
CO Returns, Honeywell Analytics, 4 Stinsford Road,
Nufeld Industrial Estate, Poole, BH17 0RZ.
An accompanying letter should state clearly any problem
with the Carbon Monoxide alarm. This guarantee does not
Register your detector at
www.sfdetection.com
Find out more www.honeywellanalytics.com
Contact us:
UK customer service centre
Honeywell Analytics Ltd. 4 Stinsford Road Nufeld Industrial Estate Poole, Dorset BH17 0RZ
Tel: +44 (0)1202 645577 Fax: +44 (0)1202 665331
consumer@honeywell.com
Europe, Middle East, Africa, India Life Safety Distribution AG Weiherallee 11a CH-8610 Uster
Switzerland Tel: +41(0)44 943 4300 Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Americas Honeywell Analytics, Inc
405 Barclay Blvd. Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8208
detectgas@honeywell.com
Asia Pacic
Honeywell Analytics Asia Pacic #508, Kolon Science Valley (I)
187-10 Guro-Dong, Guro-Gu Seoul, 152-050 Korea
Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 0329
analytics.ap@honeywell.com
affect your statutory rights.
Technical Services
EMEAI: HAexpert@honeywell.com US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com
www.honeywell.com
Please Note:
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.
I56-3495-100
MAN0877_Issue 3_11/10_EMEAI © 2010 Honeywell Analytics
12622
Loading...