1.1 MANUFACTURER DATA
EBARA INTERNATIONAL CORPORATION
1651 CEDAR LINE DRIVE
ROCK HILL, SC 29730
1.2 PUMP DATA
Description: SUBMERSIBLE SOLIDS PUMP
Model:
Year of manufacture:
If the malfunction of the pump is not among those included in the trou-
bleshooting table (chapter 14. I), contact the nearest appointed dealer.
This publication contains all the necessary information and instructions for
use and maintenance of your submersible sewage pump.
Follow the advice given to obtain optimum performance and correct operation of the pump. For any other information you may require, please contact
the nearest appointed distributor.
WSP5OAM, WSP50AA, WSPI OOAM, WSPI OOAA
see plate on the pump.
IT IS STRICTLY FORBIDDEN TO REPRODUCE THE ILLUSTRATIONS AND
THE TEXT, EVEN IN PART.
1. MANUFACTURER AND MACHINE
IDENTIFICATION DATA
1.1 Manufacturer data
I.2 Pump data
2. INFORMATION ON TECHNICAL ASSISTANCE
3. INTRODUCTION
4. CONTENTS
5. GENERAL SAFETY WARNINGS
5.1. Preventive measures to be taken by the user
5.2. Significant protection and precautions
6. DESCRIPTION
6.1 General description
page 7
page 1
page 1
page
7
page 1
page l-2
we 3
page 3
page 3
page 4
page 4
7. TECHNICAL DATA CARD
7.1. Pump technical data
7.2. Motor technical data
8. RECOMMENDED AND NON-RECOMMENDED USES
8.1. Recommended conditions of use
8.2. Non-recommended conditions of use
9. HANDLING AND TRANSPORT
9.1. Unpacking
9.2. Handling and disconnecting
9.3. Transport
10. INSTALLATION
10.1. Fixed installation
10.2. Temporary installation
11. ASSEMBLY AND DISASSEMBLY
12. PREPARATION FOR USE
12.1. Electric connection
12.2. Adjusting and registering
13. USE AND STARTUP
7 3.1. Automatic Pumps
13.2. Manual Pumps
14. MAINTENANCE AND REPAIRS
14.1. Troubleshooting
15. TECHNICAL DOCUMENTS SUPPLIED
15.1. Diagram for installation with minimum
functional spaces (fig. I)
15.2. Wiring diagram for WSP50AA, WSPI OOAA
15.3. Wiring diagram for WSPSOAM, WSPI OOAM
15.4. Diagram for cleaning the pump impeller (fig.4)
16. Warranty Information
page 4-5
page 4
page 5
page 5
page 5
page 5
page
6
iwe
6
iwe
6
page
6
page 7
page 7
page ,7
Page 7
page
8
page
8
page
8
paw
8
i-we
8
f-we
8
page 8- 10
page 9-10
page 71
page 71
page 12
page 72
page 13
page 74
FAILURE TO OBSERVE THESE WARNINGS AND /OR TAMPERING WITH
THE PUMP RELIEVES THE MANUFACTURER OF ANY RESPONSIBILITY IN
THE EVENT OF DAMAGE TO PERSONS OR OBJECTS AND/OR TO THE
PUMP.
Before starting the pump it is important for the user to know how to per-
form all the operations described in this manual and to apply them at all
times during use or maintenance of the pump.
5.1. PREVENTIVE MEASURES TO BE TAKEN BY THE USER
The user must comply with all the accident-prevention regulations
A
tions given in chapters 7.1 and 7.2 must be scrupulously followed.
in force in the country in which the pump is being used; the indica-
!
During pump repairs or maintenance, remove the plug from the
socket and/or turn off the switch (if provided), thus interrupting the
supply of electric power to the pump. This will prevent accidental
starting which could cause damage to persons and/or objects.
All maintenance operations, installations or shifting of the pump
with the electric system live may cause severe or fatal injury.
During operation, avoid moving or shifting the pump.
Before using the pump, always check that the cable and all the
electric devices are in working condition
Never start the pump (by inserting the plug in the socket and/or
switching on the switch) with bare feet, with your feet in the water,
or with wet hands.
The user must not carry out under his own initiative any operations
or jobs not recommended in this manual.
5.2 GENERAL SAFETY WARNINGS
WSP50 AND WSPlOO pumps are designed in such a way that all
!
A
the moving parts are protected by the use of casings. The manufacturer declines all responsibility in the event of damage caused
as a result of tampering with these devices.
f
A
Each lead or live part is electrically insulated to ground: there is also a further
safety device in that the accessible conductive parts are connected to a
ground lead so that the parts within reach do not become electrically charged
in the event of failure of the principal insulation.
6.1 GENERAL DESCRIPTION
WSPSO
constructive point of view; the only differences are the following:
-power
-flow rate
-head
-weight
-dimensions
WSP50 and WSPlOO series pumps are used for handling water, even at high
temperatures (chapter 7.7). Thanks to their small bulk and ease of transport,
they may be used for fixed or temporary installations, with or without auto-
matic start.
These pumps guarantee long life and constant performance if used according to the
indications given in chapter 8 and chapter 74.
7.1. PUMP TECHNICAL DATA
Max. fluid temperature
Max. dimension suspended solids
Max. immersion depth
Length of power cable
Type of impeller
Type of seal on the shaft
Type of bearing
and
WSPl 00 series pumps are all similar from the functional and
104”F/40”C
2 inch
33 feet
25
feet
single channel
double mechanical seal
in an oil chamber
shielded ball bearing
Delivery diameter
Impeller material
Pump structure material
Motor structure material
Seal cover material
7.2. MOTOR TECHNICAL DATA WSP5O/WSPlOO
Power (Versions)
l/2
7 hp
hp
7%
Poles
Insulation class
Degree of protection
Type of duty
Phase-frequency-voltage
Overload protection
Motor structure material
Shaft material
Cable material
THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE TECHNICAL
DATA IN ORDER TO MAKE IMPROVEMENTS AND BRING THEM UP-TODATE.
m Failure to respect the prescribed limits constitutes a situation of use
that is technically improper and endangers the safety of persons,
RELIEVING THE MANUFACTURER OF ANY RESPONSIBILITY IN
THE EVENT OF ACCIDENTS TO PERSONS OR DAMAGE TO
OBJECTS OR TO THE PUMP, AND ALSO RENDERING THE GUAR-
ANTEE INVALID.
.L
F
IP58
continuous
single-phase
6OHz 775
thermal protection
single-phase
molded steel
stainless steel
sow-A/so
8.1. RECOMMENDED CONDITIONS OF USE
WSP50 and WSPl 00 series pumps may be used for handling dirty or semi-
dirty water or water with suspended bodies with a diameter no greater than
50 mm; for draining garages,cellars, basements, swimming pools, basins,
tanks, fountains, drains, cesspools, sewage collection drains from cesspools;
for draining excavations, flowing irrigation from ditches, rainwater tanks or
streams.
The pump may be used for continuous duty only if totally submerged.
Use the pump in keeping with its technical characteristics (chapter 7).
I
8.2. NON-RECOMMENDED CONDITIONS OF USE
WSP50 and WSPl 00 series pumps cannot be used for handling water con-
taining acids and corrosive liquids in general, water with temperatures higher
than 4O”C, sea-water, flammable and generally dangerous liquids.
WSP50 and WSPl 00 pumps must never be allowed to run without water.
I
I
5
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.