Thank you for purchasing a Honda generator. We want to help you get the
best results from your new generator and to operate it safely. This manual
contains the information on how to do that; please read it carefully.
This owner’s manual describes the operation and maintenance of the
EM5000SXKl Honda Generator. All information in this publication is based
on the latest product information available at the time of printing. Honda
Motor Co., Ltd. reserves the right to make changes at any time without notice
and without incurring any obligation. No part of this publication may be
reproduced without written permission.
This manual should be considered a permanent part of the generator and
should remain with it if it is resold.
Safety Messages
Your safety and the safety of others is very important. We have provided
important safety messages in this manual and on the generator. Please read
these messages carefully.
A safety message alerts you to potential hazards that could hurt you or
others. Each safety message is preceded by a safety alert symbol Lfi and
one of three words: DANGER, WARNING, or CAUTION.
These mean
D ’
!
m You WILL be KILLED or SERIOUSLY HURT if you don’t
follow instructions.
L -
!
m You CAN be KILLED or SERIOUSLY HURT if you don’t
follow instructions.
9 *
r You CAN be HURT if you don’t follow instructions.
.
Each message tells you what the hazard is, what can happen, and what you
can do to avoid or reduce injury.
a
Damage Prevention Messages
You will also see other important messages that are preceded by the word
NOTICE.
This word means:
-1 Your generator or other property could be damaged if
you don’t follow instructions.
The purpose of these messages is to help prevent damage to your generator,
other property, or the environment.
1
CONTENTS
SAFETY
Safety Label Locations
Safety Information
COMPONENT IDENTIFICATION
CONTROLS
Engine Switch
Recoil Starter
Fuel Valve
Choke Rod
Circuit Breaker
These labels warn you of potential hazards that can cause serious injury.
Read them carefully.
If a label comes off or becomes hard to read, contact your Honda Generator
dealer for a replacement.
lCHfCK fOR SPIlltO fllfl OR flJf1 LfAKS.
STOP tW6INL BEDIRt RtWLlNG.
lCONlR6lfR NI’IL NY A NI Wt PI WINCE
RiPANDUf SUR L’APPARtlL.
ARRhR Lt HOTtUR AVANI Dt RtlAlRt It PLtlN.
IINSPKiCIONAR PARA COMRUSTIRlt OfRRAMADO
(@
0 ESCAPE.
PARAR YOIOR ANKS Ot fCHAR.
/
l
0
WARNING DO NOT !JSE INDOORS. EXHAUST GAS CONTAINS POISONOUS
CARBON MONOXIDE.
ATTENTION NE PAS” UTILISER OANS UN ENDROIT FERME A CAUSE DU
RISOUE D’EMPOISONNEMENT DU GAZ.
ATENCl()N NO LO. USE’EN LUGARES CERRADOS’POROUE EL MONOXIDE
DE CARBON0 ES
VENENOSO.
ITOR CO.. LTD.
II
n BE SUR~fb?ILL CRANKCASE 11 VOLTAGE
WITH RECOMMENDED OIL
BEFORE USING~
FOR DETAILEO -___ -_ ____ __ _-..I
SEE THE OWNER’S MANUAL
CAUTION
. .---
_.---- -.-
~‘EXPLANATI~~U.
II
-.--- ~-- ~-~
FREQUENCY
RATED OUTPUT
I/
MAX. OUTPUT
PHAsE
MADE IN JAPAN @i
AC II DC
120/24OV 11 VOLTAGE
60Hz
4.5kVA
CURRENT
II 5.OkVA -..-. -_--_ ___-
10/[ FUEL “;=J&~;j
ARA
12v
5
SAFETY INFORMATION
Honda generators are designed to give safe and dependable service if
operated according to instructions. Read and understand this owner’s
manual before operating your generator. You can help prevent accidents by
being familiar with your generator’s controls, and by observing safe operating
procedures
Operator Responsibility
. Know how to stop the generator quickly in case of emergency.
l
Understand the use of all generator controls, output receptacles, and
connections.
l
Be sure that anyone who operates the generator receives proper
instruction. Do not let children operate the generator without parental
supervision.
Carbon Monoxide Hazards
l
Exhaust contains poisonous carbon monoxide, a colorless and odorless
gas. Breathing exhaust can cause loss of consciousness and may lead
to death.
l
If you run the generator in an area that is confined, or even partially
enclosed, the air you breathe could contain a dangerous amount of
exhaust gas. To keep exhaust gas from building up, provide adequate
ventilation.
Electric Shock Hazards
l
The generator produces enough electric power to cause a serious shock
or electrocution if misused.
l
Using a generator or electrical appliance in wet conditions, such as rain
or snow, or near a pool or sprinkler system, or when your hands are wet,
could result in electrocution. Keep the generator dry.
l
If the generator is stored outdoors, unprotected from the weather, check
all electrical components on the control panel, before each use. Moisture
or ice can cause a malfunction or short circuit in electrical components
which could result in electrocution.
l
Do not connect to a building’s electrical system unless an isolation switch
has been installed by a qualified electrician.
6
Fire and Burn Hazards
l
The exhaust system gets hot enough to ignite some materials.
-
Keep the generator at least 1 meter (3 feet) away from buildings and
other equipment during operation.
- Do not enclose the generator in any structure.
-
Keep flammable materials away from the generator.
l
The muffler becomes very hot during operation and remains hot for a
while after stopping the engine. Be careful not to touch the muffler while
it is hot. Let the engine cool before storing the generator indoors.
l
Gasoline is extremely flammable and is explosive under certain
conditions. Do not smoke or allow flames or sparks where the generator
is refueled or where gasoline is stored. Refuel in a well-ventilated area
with the engine stopped.
l
Fuel vapors are extremely flammable and may ignite after the engine has
started. Make sure that any spilled fuel has been wiped up before starting
the generator.
7
COMPONENT IDENTIFICATION
VOLT METER
ENGINE SWITCH
CHOKE ROD
RCUlT BREAKER
8
UN0 TERMINAL
ENGINE SERIAL NUMBER
FUEL TANK CAP
FUEL METER
-SPARK PLUG
CAP
SERIAL NUMBER
MUFFLER
l
Record the engine and frame serial numbers for your future reference.
Refer to these serial numbers when ordering parts, and when making
technical or warranty inquiries (see page 47)
Frame serial number:
Engine serial number:
9
CONTROLS
Engine Switch
To start and stop the engine.
Key position:
OFF:
ON:
START:
ENGINE
Return the key to the ON position once the engine has started. Do not use
the starter for more than 5 seconds at a time. If the engine fails to start, release
the switch and wait 10 seconds before operating the starter again.
To Stop the engine. Key can be removed/inserted.
To run the engine after starting.
To start the engine by turning the starter
motor.
Recoil Starter
To start the engine, pull the starter grip lightly until resistance is felt, then pull
briskly.
[I Do not allow the starter to snap back against the engine.
Return it gently to prevent damage to the starter.
IO
Fuel Valve
The fuel valve is located between the fuel tank and carburetor. When the
valve lever is in the ON position, fuel is allowed to flow from the fuel tank to
the carburetor. Be sure to return the lever to OFF after stopping the engine.
Choke Rod
The choke is used to provide proper starting mixture when the engine is cold.
It can be opened and closed by operating the choke rod manually. Pull the
rod out toward CLOSED to enrich the mixture.
11
Circuit Breaker
The circuit breaker will automatically switch OFF if there is a short circuit or
a significant overload of the generator at the receptacle. If the circuit breaker
is switched OFF automatically, check that the applicance is working properly
and does not exceed the rated load capacity of the circuit before switching
the circuit breaker ON again.
The circuit breaker may be used to switch the generator power on or off.
Ground Terminal
The gernerator ground terminal is connected to the frame of the generater,
the metal non-current carrying parts of the generator, and the ground
terminals of each receptacle.
AC CIRCUIT BREAKER
GROUND TERMINAL
Oil Alert System
The Oil Alert system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the
crankcase can fall below a safe limit, the Oil Alert system will automatically
shut down the engine (the engine switch will remain in the ON position). If the
Oil Alert system shuts down the engine, the Oil Alert lamp will flash when you
operate the starter, and the engine will not start. If this occurs, add engine oil
(P-24).
12
Auto-throttle System
The auto-throttle system automatically reduces engine speed when all loads
are turned off or disconnected. When appliances are turned on or
reconnected, the engine returns to the rated speed.
AUTO:
OFF:
Recommended to minimize fuel consumption and
further reduce noise levels when no load is applied to
the generator.
The auto-throttle system does not operate.
SWITCH
13
Pilot Lamp
The pilot lamp is illuminated when the generator is operating normally. It
indicates that the generator is producing electrical power at the 120 or 120/
240 volt receptacles. If the pilot light is illuminated, the volt meter should be
displaying 120 or 240 volts depending on the position of the voltage selector
switch.
When the auto-throttle is in the AUTO position, and there is no load
connected to the generator, the engine will run slower and the pilot light will
be dimmer than at normal operating speed.
Volt Meter
The volt meter,displays the voltage the generator is producing depending on
the position of the voltage selector switch. If the voltage selector switch is in
the “120/240 V” position, the volt meter will display 240 volts. If the voltage
selector switch is in the “120 V ONLY” position, the volt meter will display 120
volts.
Voltage Selector Switch (Dual voltage System)
The voltage selector switches the main power carrying windings of the
generator to produce “12OV ONLY” or “120/24OV”. If a 240V appliance is
connected to the 4-prong receptacle, the switch must be in the “120/24OV”
position. If a 120V appliance ONLY is being connected to any of the 120V
3-prong receptacles, select the “120V ONLY” position.
120/24OV:
12OV ONLY:
The 12OV and 120/24OV receptacles can be used
simultaneously.
ONLY the 12OV receptacles can be used. Do not use
the 120/24OV receptacle in this position. Rated power
will be available at the 12OV twist lock receptacle.
PILOT
LAF(P
VOLTAGE SELECTOR
SWIT/CH
14
VOLT METER
DC Terminals
The DC terminals may ONLY be used for charging 12 volt automotive type
batteries.
The terminals are colored red to identify the positive (+) terminal and black
to identify the negative (-) terminal. The battery must be connected to the
generator DC terminals with the proper polarity (battery positive to generator
red terminal and battery negative to the generator black terminal).
DC Circuit Protector
The DC circuit protector automatically shuts off the DC battery charging
circuit when the generator is overloaded, when there is a problem with the
battery or the connections between the battery and the generator are
improper.
DC CIR
PROTE
NEGATliE TiRMINAL
(BLACK)
POSlilVE TERMINAL
(RED)
15