Honda Automobiles WT30X, and WT40X, WT20X, WT40X User Manual

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
Keep this owner’s manual handy, so you can refer to it at any time.
This owner’s manual is considered a permanent part of the water
The information and specifications included in this publication were in
effect at the time of approval for printing. Honda Motor Co., Ltd.
reserves the right, however, to discontinue or change specifications or design at any time without notice and without incurring any obligation whatever. No part of this publication may be reproduced without written permission.

INTRODUCTION

Congratulations on your selection of a Honda water pump. We are certain you will be pleased with your purchase of one of the finest water pumps on the market.
We want to help you get the best results from your new water pump
and to operate it safely. This manual contains the information on how
to do that; please read it carefully.
As ou read this manual, you will find information preceded by a
&iq
damage to your water pump, other property, or the environment.
We suggest you read the warranty policy to fully understand its
coverage and your responsibilities of ownership. The warranty policy
is a separate document that should have been given to you by your dealer.
When your water pump needs scheduled maintenance, keep in mind that your Honda servicing dealer is specially trained inservicing
Honda water pumps. Your Honda servicing dealer is dedicated to your satisfaction and will be pleased to answer your questions and
concerns.
symbol. That information is intended to help you avoid
Best Wishes, Honda Motor Co., Ltd.
1
INTRODUCTION

A FEW WORDS ABOUT SAFETY

Your safety and the safety of others are very important. And using this water pump safely is an important responsibility.
To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others.
Of course, it is not practical or possible to warn you about all the hazards associated with operating or maintaining a water pump. You must use your own good judgment.
You will find important safety information in a variety of forms, including:
l Safety Labels - on the pump. l Safety Messages - preceded by a safety alert symbol A and one
of three signal words, DANGER, WARNING, or CAUTION.
These signal words mean:
You WILL be KILLED or SERIOUSLY HURT if you don’t.follow instructions.
You CAN be KILLED or SERIOUSLY HURT if you don’t follow instructions.
You CAN be HURT if you don’t follow
instructions.
l Safety Headings - such as IMPORTANTSAFETYINFORMATION.
l Safety Section - such as PUMP SAFETY
l Instructions
- how to use this pump correctly and safely.
This entire book is filled with important safety information - please
read it carefully.
2

CONTENTS

PUMP SAFETY ........................................................................................... 5
IMPORTANT SAFETY INFORMATION SAFETY LABEL LOCATIONS
.... . ............................................................ 7
................................................. 5
CONTROLS & FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..~..................
COMPONENT & CONTROL
CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fuel Valve Lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ignition Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Choke Lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Throttle Lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recoil Starter Grip . . . . . . ..~~.~..~.......~~............~...............~....................... 11
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Oil Alert@ System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BEFORE OPERATION ..............................................................................
ARE YOU READY TO GET STARTED?
IS YOUR PUMP READY TO
Check the General Condition Check the Suction and Discharge Hoses
Check the Engine ..............................................................................
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..~............................................................. 15
SAFE OPERATING PRECAUTIONS
PUMP PLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SUCTION HOSE INSTALLATION
DISCHARGE HOSE INSTALLATION
PRIMING THE PUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STARTING THE ENGINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SETTING ENGINE SPEED ,................................................................... 21
STOPPING THE ENGINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCATIONS . . . . . . . . . . . . . . . . . . . . . . . ..a................... 8
IO 10
11 11
12
................................................ 12
GO? ......................................................... 13
of the Pump ..................................... 13
........................................ 14
14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
18 19
22
8 9
9 9
SERVICING YOUR HONDA PUMP
THE IMPORTANCE OF MAINTENANCE
MAINTENANCE SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE SCHEDULE
REFUELING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FUEL RECOMMENDATIONS ENGINE OIL LEVEL CHECK
ENGINE OIL CHANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
25
27
30
3
CONTENTS
SERVICING YOUR HONDA PUMP (continued)
ENGINE OIL RECOMMENDATIONS AIR FILTER INSPECTION AIR FILTER CLEANING SEDIMENT CUP CLEANING SPARK PLUG SERVICE IDLE SPEED ADJUSTMENT SPARK ARRESTER
PUMP CASING
SERVICE
CLEANING
.....................................................................
........................................................................
................................................................
........................................................................
................................................................
(optional equipment)
.................................................................
...................................................
..........................
31 32
33 34 35 37
38
40
STORAGE
STORAGE PREPARATION
Cleaning Fuel Engine Oil
STORAGE PRECAUTIONS
REMOVAL FROM STORAGE
TRANSPORTING
TAKING CARE OF UNEXPECTED PROBLEMS
ENGINE
Engine Will Not Start Engine Lacks Power
PUMP
No Pump Output Low Pump Output
TECHNICAL & CONSUMER INFORMATION
TECHNICAL INFORMATION
Serial Number Location Carburetor Modification for High Altitude Operation
Oxygenated Fuels Emission Control System Information
Air Index
Specifications
CONSUMER INFORMATION
Honda Publications
Warranty Service Information
.................................................................................................
...................................................................
............................................................................................
....................................................................................................
.......................................................................................... 45
..................................................................
...............................................................
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.................................................................................................
.......................................................................
.........................................................................
....................................................................................................
..............................................................................
............................................................................
................................................................ 50
...................................................................
............................................................................
............................................................................................
...................................................................................
...............................................................
..........................................................................
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
...........................................
.........................................................
. . . . . . . . . . . . 47
......................................
.........................................
...................
41
41 41
42
45 46
48 48 48 48
49
49 49
50 50
51
52. 53
55 56 62 62 63
QUICK REFERENCE INFORMATION
4
............................
Inside back cover

PUMP SAFETY

IMPORTANT SAFETY INFORMATION

Honda WT20X, WT30X, and WT40X pumps are designed to pump only
water that is not intended for human consumption, and other uses can
result in injury to the operator or damage to the pump and other property.
Most accidents can be prevented if you follow all instructions in this manual and on the pump. The most common hazards are discussed below, along with the best way to protect yourself and others.
Operator Responsibility
It is the operator’s responsibility to provide the necessary safeguards to protect people and property. Know how to stop the pump quickly in case of emergency. If you leave the pump for any reason, always turn the engine off. Understand the use of all controls and connections.
Be sure that anyone who operates the pump receives proper
instruction. Do not let children operate the pump. Keep children and
pets away from the area of operation.
Pump Operation
Pump only water that is not intended for human consumption.
Pumping flammable liquids, such as gasoline or fuel oils, can result in
a fire or explosion,
beverages, acids, chemical solutions, or any other liquid that
promotes corrosion can damage the pump.
Refuel With Care
Gasoline is extremely flammable, and gasoline vapor can explode.
Refuel outdoors, in a well-ventilated area, with the engine stopped and the pump on a level surface. Do not fill the fuel tank above the fuel
strainer shoulder. Never smoke near gasoline, and keep other flames and sparks away. Always store gasoline in an approved container.
Make sure that any spilled fuel has been wiped up before starting the engine.
causing serious injury. Pumping sea water,
5
PUMP SAFETY
Hot Exhaust
The muffler becomes very hot during operation and remains hot for a while after stopping the engine. Be careful not to touch the muffler while it is hot. Let the engine cool before transporting the pump or
storing it indoors.
To prevent fire hazards, keep the pump at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not
place flammable objects close to the engine.
Carbon Monoxide Hazard
Exhaust gas contains poisonous carbon monoxide. Avoid inhalation of
exhaust gas. Never run the engine in a closed garage or confined area.
6
PUMP SAFETY

SAFETY LABEL LOCATIONS

The labels shown here contain important safety information. Please
read them carefully. These labels are considered permanent parts of your pump. If a label comes off or becomes hard to read, contact an
authorized Honda servicing dealer for a replacement.
J \~ETERSO~AL INJURY.
PUMP CAUTION LABEL
PRECAUTION! NC FAITE PAS FON-
7

CONTROLS & FEATURES

COMPONENT & CONTROL LOCATIONS

<wT2ox>
FUEL FILLER CAP
AIR CLEANER
THROTTLE LEVER
PRIMING/WATER
FILLER CAP
CHOKE LEVER
FUEL VALVE L
STARTER GRIP
PRIMING WATER FILLER CAP
SUCTION
PORT
IGNITION SWITCH
/
‘DISCHAR,GE
CASE DRAIN PI
OIL FlLiER CAP/DIPSTICK
, MUFFLER
PORT
JJG
COVER DRAIN PLUG
t
STRAINER

CONTROLS

Fuel Valve Lever

CONTROLS & FEATURES
The fuel valve opens and closes the connection between the fuel tank and the carburetor.
The fuel valve lever must be in the ON position for the engine to run.
When the engine is not in use, leave the fuel valve lever in the
OFF position to prevent carburetor flooding and to reduce
the possibility of fuel leakage.

Ignition Switch

The ignition switch controls the
ignition system.
The ignition switch must be in the
ON position for the engine to run.
Turning the ignition switch to the OFF position stops the engine.
FUEL VALVE LEVER
OFF -I
IGNITION SWITCH
9
CONTROLS & FEATURES

Choke Lever

The choke lever opens and closes the choke valve in the carburetor.
!
The CLOSED position enriches
the fuel mixture for starting a cold
engine.
The OPEN position provides the correct fuel mixture for operation after starting, and for restarting a warm engine.

Throttle Lever

The throttle lever controls engine
speed. Moving the throttle lever in
directions shown makes
the \,
the i
engine run faster or slower.
Pump output is controlled adjusting the throttle lever. maximum throttle position,
by :.
At ‘\
the \
pump will deliver the highest ) 1 output volume. Moving the throttle lever toward the idle
position will decrease the output volume of the pump.
CHOKE LEVER
i
I
! .\
10
CONTROLS & FEATURES

Recoil Starter Grip

Pulling the starter grip operates the recoil starter to crank the engine.
STARTER GRIP

FEATURES

Oil Alert@ System
The Oil Alert@ system is designed to prevent engine damage caused
by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert@ system will automatically stop the engine (the ignition switch will remain in the ON position).
If the engine stops and will not restart, check the engine oil level (page
29 ) before troubleshooting in other areas.
11

BEFORE OPERATION

ARE YOU READY TO GET STARTED?
Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury.
Knowledge
Read and understand this manual. Know what the controls do and
how to operate them.
Familiarize yourself with the pump and its operation before you begin
pumping. Know what to do in case of emergencies.
Be sure of what you are pumping. This pump is designed to pump
only water that is not intended for human consumption.
12
BEFORE OPERATION

IS YOUR PUMP READY TO GO?

For your safety, and to maximize the service life of your equipment, it is very important to take a few moments before you operate the pump
to check its condition. Be sure to take care of any problem you find, or
have your servicing dealer correct it, before you operate the pump.
Improperly maintaining this pump, or failing to correct a problem before operation, could cause a malfunction in which you could be
seriously injured.
Always perform a preoperation inspection before each operation, and correct any problem.
Exhaust gas contains poisonous carbon monoxide. Avoid inhalation of exhaust gas. Never run the engine in a closed garage or confined area.
To prevent fire hazards, keep the pump at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not
place flammable objects close to the engine. Before beginning your preoperation checks, be sure the pump is on a
level surface and the ignition switch is in the OFF position.
Check the General Condition of the Pump
l Look around and underneath the pump for signs of oil or gasoline
leaks.
l Remove any excessive dirt or debris, especially around the engine
muffler, and recoil starter.
l Look for signs of damage. l Check that all nuts, bolts, screws, hose connectors and clamps are
tightened.
13
BEFORE OPERATION
Check the Suction and Discharge Hoses
l Check the general condition of the hoses. Be sure the hoses are in
serviceable condition before connecting them to the pump.
Remember that the suction hose must be reinforced construction to prevent hose collapse.
l Check that the sealing washer in the suction hose connector is in
good condition (see page 17 ).
l Check that the hose connectors and clamps are securely installed
(see pages 17& 18).
l Check that the strainer is in good condition and is installed on the
suction hose (see page 17 ).
Check the Engine
l Check the oil level (see page 29 ). To avoid the inconvenience of an
unexpected shutdown by the Oil Alert@ system, always check the engine oil level before startup.
l Check the air filter (see page32 ). A dirty air filter will restrict air flow
to the carburetor, reducing engine and pump performance.
l Check the fuel level (see page 27 ). Starting with a full tank will help
to eliminate or reduce operating interruptions for refueling.
14

OPERATION

SAFE OPERATING PRECAUTIONS

To safely realize the full potential of this pump, you need a complete understanding of its operation and a certain amount of practice with its controls.
Before operating the pump for the first time, please review the
IMPORTANT SAFETY INFORMATION on page 5 and the chapter titled BEFORE OPERA TION.
For your safety, avoid starting or operating the engine in an enclosed area, such as a garage. Your engine’s exhaust contains poisonous carbon monoxide gas which can collect rapidly in an enclosed area and cause illness or death.
Pump only water that is not intended for human consumption. Pumping flammable liquids, such as gasoline or fuel oils, can result in a fire or explosion, beverages, acids, chemical solutions, or any other liquid that promotes corrosion can damage the pump.
causing serious injury. Pumping sea water,
15
OPERATION

PUMP PLACEMENT

For best pump performance, place the pump near the water level, and
use hoses that are no longer than necessary. That will enable the
pump to produce the greatest output with the least self-priming time. As head (pumping height) increases, pump output decreases.
Maximum head specifications and pump performance curves are shown in the tables on pages 57,59 and 61 . The length, type, and size of the suction and discharge hoses can also significantly affect pump output.
Discharge head capability is always greater than suction head capability, so it is important for suction head to be the shorter part of total head.
Minimizing suction head (placing the pump near the water level) is also very important for reducing self-priming time. Se/f-priming time
is the time it takes the pump to bring water the distance of the suction
head during initial operation.
16
TOTAL HEAD
OPERATION

SUCTION HOSE INSTALLATION

Use the commercially available hose and hose connector with the hose clamp provided with the pump. The suction hose must be reinforced with a noncollapsible wall or braided wire construction.
The suction hose should be no longer than necessary. Pump performance is best when the pump is near the water level, and the hoses are short.
Use a hose clamp to securely fasten the hose connector to the suction hose in order to prevent air leakage and loss of suction. Verify that the hose connector sealing washer is in good condition.
Install the strainer (provided with the pump) on the other end of the suction hose, and secure it with a hose clamp. The strainer will help to prevent the pump from becoming clogged or damaged by debris.
Securely tighten the hose connector on the pump suction port.
HOSE CONNECTOR
SUCTION PORT
HOSE CLAMP
\
SEA/LING WASHER (commercially available)
HOSE COUPLER (commercially available)
/SUCTION HOSE
m (commercially
HOSE CLAMP
available)
OPERATION

DISCHARGE HOSE INSTALLATION

Use a commercially available
HOSE CONNECTOR
hose with the hose connector and
clamp provided with the pump.
It is best to use a short, large­diameter hose, because that will reduce fluid friction and improve pump performance. A long or small-diameter hose will increase fluid friction and reduce pump output.
Tighten the hose clamp securely to prevent the discharge hose
HOSE CLAMP
from disconnecting under high
pressure.

PRIMING THE PUMP

Before starting the engine, remove the filler cap from the pump chamber, and completely fill the pump chamber with water. Reinstall the filler cap, and tighten it securely.
Operating the pump dry will destroy the pump seal. If the pump has
been operated dry, stop the engine immediately, and allow the pump to cool before priming.
PRIMING WATER FILLER CAP
18
/
1

STARTING THE ENGINE

1. Move the fuel valve lever to the ON position.
FUEL VALVE LEVER
i
i
I
,
i
OPERATION
i
\
2. To start a cold engine, move the choke lever to the CLOSED position.
To restart a warm engine, leave the choke lever in the OPEN position.
CHOKE LEVER
3. Move the throttle lever away from the SLOW position, about l/3 of the way toward the FAST position.
THROl-iLE LEVER