Honda Automobiles EB3500X User Manual

Owner's Manual
EB3500X
©1985 Honda Motor Co., Ltd. — All Rights Reserved
Thank you for purchasing a Honda generator. This manual covers operation and maintenance of the EB3500X
generators. All information in this publication is based on the latest product
information available at the time of approval for printing. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation.
No part of this publication may be reproduced without written permission. This manual should be considered a permanent part of the generator and
remain with the generator when sold. Pay special attention to statements preceded by the following words:
mm
life if instructions are not followed. CAUTION: Indicates a possibility of personal injury or equipment damage,
if instructions are not followed.
Indicates a strong possibility of severe personal injury or loss of
NOTE: Gives helpful information.
If a problem should arise, or if you have any questions about the generator, consult an authorized Honda dealer.
m The Honda generator is designed to give safe and dependable service if operated according to instructions. Read and understand the Owner’s Manual before operating the generator. Failure to do so could result in personal injury or equipment damage.
1
I

CONTENTS

CONTENTS
/
1. WARNING LABEL LOCATION
2. GENERATOR SAFETY
... . .......................................................
3. COMPONENT IDENTIICATION
4. PRE-OPERATION CHECK
5. STARTING THE ENGINE
6. GENERATOR USE
.................................................................
7. STOPPING THE ENGINE
8. MAINTENANCE
......................
9. TRANSPORTll\jG/STORAGE
.................................................
................................................
..................... .
.................................
........................................................
........................................................
.:
...........................................
...........................................
10. TROUBLESHOOTING ............................................................
11. SPECIFICATIONS
12. WIRING DIAGRAM
13. HANGER KIT INSTALLATION
14. INSTALLATION OF OPTIONAL PARTS
15. WARRANTY SERVICE ...............................
..................................................................
....................................................
.................................................
.....................................
.
...........................
3 5 6
8 12 15 18 20
.: ....... 28
30 32
. ........... 33
34 35
36
2

1. WARNING LABEL LOCATION

ATTENTION NE PAS UTILISER DANS UN ENDROIT FERME A CAUSE
DU RISQUE D’EMPOISONNEMENT DU GAZ.
ATENClON NO LO USE EN LUGARES CERRADOS PORQUE EL
L
MONOXIDE DE CARBON0 ES VENENOSO.
I
STOP ENGINE BtFORf RfFUftlN~
mCONlROLfR OU’IL N’V A.NI FUIIE NI fSSfNCt
, ARRfTfR Lf MOIfUR AVANT Of RfFAIRf Lf PIEIN.
mlNSPfCClONAR PARA COMBUSllBLf DfRRAMAOO
0 ESCAPE PARAR MIlTOR ANlfS Of ECHAR
I
//
3
I
EB350OX
H BE SURE TO FILL CRANKCASE WITH RECOMMENDED OIL BEFORE USING. FOR DETAILED EXPLANATION, SEE THE OWNER’S MANUAL.
c
CAUTION
HONDA MOTOR CO., LTD. MADE IN JAPAN B’
, FUEL GASOLINE (PETROL)
VOLTAGE AC 12Ol24OV FREQUENCY RATED OUTPUT h&4f$UTPUT
60Hz
3.OkVA
3.5kVA 10
4

2. GENERATOR SAFETY

m *
To ensure safe operation -
Place the generator at least 1 m (3 ft) away from buildings or other equipment when operating the generator. Operate the generator on a level surface. If the generator is tilted, fuel spillage .may result. Exhaust gas contains posionous carbon monoxide. Never run the generator in an enclosed area. Be sure to provide adequate ventilation.
Know how to stop the generator quickly and understand operation of all
the controls. Never permit anyone to operate the generator without pro-
per instructions. Keep children and pets away from the generator when it is in operation. Keep away from rotating parts while the generator is running. The generator is a potential source of electrical shocks when misued; do not operate with wet hands. Do not operate the generator in rain or snow and do not let it get wet.
.’

3. COMPONENT IDENTIFICATION

VOLTAGE SELECTOR
SWITCH
RECERTACLES
6
VALVE
THROTTLE SWITCH
FILLER CAP
OIL DRAIN PLUG
RECOIL STARTER GRIP
FUEL TANK CAP
.
7
I’ I
I
4. PRE-OPER&TUON CWECK
Engine Oil CAUTION:
l
Engine oil is a major factor affecting engine performance and service life. Non-detergent
l
Be sure to.check .the engine on a level surface with the engine stopped.
Use Honda 4-stroke oil or an equivalent high detergent premium quality motor oil certified to meet or exceed U.S. auto-mobile manufacturer’s re-
quirements for Service Classification SE or SF. (Motoroils classified SE or SF will show this designation on the container.) SAE low-40 is recommended for general, all-temperature use. Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range.
1. Remove the oil filler cap and wipe the dipstick clean.
!Z. Insert the dipstick into.the oil filler neck but do not screw it in.
3. If the level is low, fill to the top of the oil filler neck with the recommend­ed oil.
oiis
and vegetable oils are not recommended.
CAUTION: Running the engine with engine damage.
OIL FILLER CAP
OIL FILLER HOLE
8
insufficient oil can cause serious
­1 ,
-30 -20 -10 0 10 20 30 40°C Ambient temperature
LEVEL
Fuel
Use automotive gasoline with a pump octane number (9) of 86 or higher, or a research octane number of 91 or higher (unleaded is prefer­red to minimize combustion chamber deposits).
Never use an oil/gasoline mixture or dirty gasoline. Avoid getting dirt, dust or water in the fuel tank.
CAUTION: Gasoline substitutes are not recommended; they may be harm­ful to the fuel system components.
iam
l
Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped.
l
Do not smoke or allow flames or sparks in the area where the generatior is refueled or where gasoline is stored.
0 Do not overfill the tank and make sure the filler cap is securely closed
after refueling.
l
Be careful not to spill fuel when refueling. Fuel vapor or spilled fuel may ignite. If any fuel is spilled, make sure the area is dry before starting the engine.
Fuel tank capacity: 6.0 lit. (12.7 US pt. 10.6 Imp pt)
1. Check the fuel level.
2. If level is low, fill to the shoulder of the fuel filter.
3. After refueling, be sure to tighten the fuel thank cap firmly.
FUEL FILI
LER CAP
FUEL FILLER UPPER LIMIT
I
I
Gasolines Containing Alcohol
If you decide to use a gasoline containing alcohol (“gasohol”), be sure the octane rating is at least as high as that recommended by Honda. There are two types of “gahohol” that containing ethanol, and that containing methanol. Do not use gasohol that contains more than 10% ethanol. Do not use gasoline containing ,methanol (methyl or wood alcohol) that does not also contain cosolvents and corrosion inhibitors for methanol. Never use
gasoline containing more than 5% methanol, even if it has cosolvents and corrosion inhibitors.
NOTE:
l
Fuel system damage or engine performance problems resulting from the use of such fuels are not covered under Power Equipment Warranties. Honda cannot endorse the use of fuels containing methanol since evidence of their suitability is as yet incomplete.
l
Before purchasing fuel from an unfamiliar station, try to confirm whether the fuel contains alcohol, and to what percentage. If you notice any undesirable operating symptoms after using a gasoline that contains alcohol, or one ttiat you think contains alcohol, switch to a ga?oline that
you know does not contain alcohol.
10
Make sure that the AC circuit breaker is in the OFF position.
The generator may be hard to start if a load is connected.
AC CIRCUIT BREAKER
11
(’ I
,
5. STARTING ‘THE ENGINE
1. Turn the fuel valve to the 4N position.
FUEL VALVE
2. Pull the choke rod to the CLOSE position.
CHOKE ROD