ORing122* x x x x x CFdgd2501-20BB x x x x CFrfgac20-20BB x x x Cfre-20BB x CfKDF85GCC-20BB x x CFpltn-20BB x
Inspect system for leaks, wear,
& signs of stress
Annually Annually Annually Annually Annually
Inspect oring for damage & de­formaon*
At lter change
At lter change
At lter change
At lter change
At lter change
Sanize System
At lter change
At lter change
At lter change
At lter change
At lter change
*It is a good idea to keep a set of spare orings - 1 per housing. You may need to chan ge them each me you open the housing.
Note: Filter life will vary based upon contaminant level and usage.
Note: protect system against freezing, direct sunlight and the elements
This informaon subject to change without nocaon
Annual Water Consumption
1 person 25,000 gallons
2 people 55,000 gallons
4 people 100,000 gallons
Customer Service Hotline 1-877-693-PURE
Perfect Water Technologies
Home Master® Water Filter
Installation & Service Manual
HMF1C HMF2SdgC HMF2SmgCC HMF3SdgFeC
HMF3SmgNCC
HMF-CYO
Customer Service Hotline 1-877-693-PURE
Page 2
Home Master® Water Filter Owners Manual
Contents:
Instruction book: detailed descriptions, photos and troubleshooting guide
Mounting bracket & screws assembled with housing cap(s) Housing sump(s) with filter(s), o-ring, and silicone grease Filter housing wrench
Maintenance Schedule
SEE APPENDIX A
General System Specifications (See Appendix A for additional Information)
Feed water: PSI 20 - 90 PSI ; for pressure greater than 90 PSI install a pressure
regulator set to 75 PSI
Feed water Tem perature: 40˚ - 100˚(F) IRON BACTER IA: NONE
Yo ur results may vary depending on regular maintenance, general condition of unit, and
initial water supply. Filter not designed to treat microbially unsafe or non-potable water without adequate disinfection before and after unit.
Customer Service Hotline 1-877-693-PURE
Page 7
Home Master® Water Filter Owners Manual
Filter Change Instructions
1. For well water—shock chlorinate your well and pipes prior to removing filters.
2. Turn off the water supply to the system. Depress the red pressure release button on the top of the filter housing cap to relieve system pressure. If your system was not equipped with a pressure relief valve, leave open a nearby faucet. This will make removing the filter housing possible.
3. Unscrew the housing (sump) from the cap using the filter wrench included with your system, or a commercially available “strap” type wrench. Remove and discard old filter cartridge.
4. Scrub the sump and cap with warm water mixed with about 2 tablespoons of household bleach using a sponge or soft rag. Wear rubber gloves.
5. A) Pour 2 cups of unscented concentrated bleach in each empty sump and close the system to hand tight and fit snug tight with the wrench. DO NOT over tighten. B) Drain your hot water heater. C) Open the main water supply to the system. D) Open a faucet at the furthest point from the system and run water until you smell the chlorine. Flush the toilet. Repeat at each point of use moving towards the filter system. E) Close the main water supply to the system. F) Open each housing.
6. Lubricate the o-ring with clean silicon grease . Be sure to use liberal amounts of grease on the lower oring so that the entire surface is covered. Failure to do so will cause binding, oring damage, leaks, and difficulties reopening the housing. DO NOT USE PETROLIUM JELLY. Insert o-ring in grove and press into place taping the o-ring all the way around. Make sure the o­ring is seated level. Replace o-ring if damaged or stretched.
7. Remove filter packaging and insert new filter cartridge into the sump, making sure that it slips over the standpipe in the bottom of the sump.
8. Fit the bottom of the housing (sump) into the cap and hand tighten, then use the filter wrench to fit snug. Do not over tighten.
9. Turn on the water supply slowly to allow the system to fill with water. Close any open valves
downstream of the system once water flows and air is purged. Inspect system carefully for leaks. If a leak is found, first follow the shut off de-pressurization procedure and then remove the housing to inspect the o-ring to ensure that it is seated properly. Then retighten.
10. Flush the system by turning on a few cold-water faucets. Allow the water to run until the air and
carbon has been purged. Water may be cloudy initially. New activated carbon filter cartridges may contain loose carbon and air bubbles after installation.