Read all Safety, Operating
and Maitenance instructions.
Thank you for buying this new HOMELITE Generator!
Homelite provides a wide range of Lawn and Garden,
Forestry and Construction Equipment products which meet
the needs of both the consumer and commercial markets.
HOMELITE products are warranted and are serviced by a
large network of servicing dealers.
CUSTOMER ASSISTANCE
FOR THE LOCATION OF YOUR NEAREST HOMELITE SERVICING DEALER IN THE UNITED STATES, PUERTO RICO,
AND THE VIRGIN ISLANDS, CALL 1-800-242-4672.
• If this generator is used for emergency standby service it will be
necessary to install a manual transfer switch between the
electric utilitiy's meter and the building's distribution panel. The
transfer switch isolates the generator and load from the utility
power line, thus avoiding any danger of electricity being fed back
to the utility lines. The installation should be done by a licensed
electrician.
• Never operate the machine in an explosive atmosphere, near
combustible materials or where ventilation is not sufficient to carry
away exhaust fumes. Exhaust fumes can cause serious injury
or death.
• When starting the machine, be sure that nothing is in a position
to be hit by the operators hand or arm.
• Be sure the switch on electric power tools is in the “OFF” position
before plugging them into the machine.
FOLLOW THESE INSTRUCTIONS TO REDUCE THE RISK OF
INJURY
• This generator is equipped with a grounding terminal for your
protection. Always complete the ground path from the generator
to an external ground source as instructed in the section labeled
“Grounding the Generator”.
• Keep the immediate area free of all bystanders.
• Be sure each person who operates this machine is properly
instructed in its safe operation.
• Do not operate this machine or any electrical tool in any area
where water or similar materials constitute an electrical hazard
to the operator. Do not operate on wet surfaces or in the rain.
• Always be sure that the machine is on secure footing so that it
cannot slide or shift around, endangering workers.
• Avoid contacting the hot exhaust manifold, muffler or cylinder.
Keep clear of all rotating parts.
• Unless the tool or appliance is double insulated, ground it. Tools
and appliances which have 3 prong plugs must be plugged into
extension cords and electrical receptacles with 3 holes. Before
operating any electrical item, be sure it is in good repair.
• BEWARE OF USING THIS EQUIPMENT IN CONFINED SPACES
Confined spaces, without sufficient fresh air ventilation, can contain
dangerous gases. Running gasoline engines in such environments can lead to deadly explosions and/or asphyxiation.
MAINTENANCE
• Use HOMELITE genuine replacement parts. Failure to do so may
cause poor fit and injury.
• Never operate machine with any guard removed.
• Shut off the engine and disconnect the spark plug wire before
working on any part of this machine.
• Always keep the machine and all associated equipment clean,
properly serviced and maintained.
REFUELING (DO NOT SMOKE!)
• Observe all safety regulations for the safe handling of fuel.
• Handle fuel in safety containers.
• If container does not have a spout, use a funnel.
• Do not refill fuel tank while the engine is running.
• Fill the tank only on an area of bare ground. While filling the tank,
keep heat, sparks and open flame away. Carefully clean up any
spilled fuel before starting engine.
John Deere Consumer Products, Inc.
P.O. Box 7047
Charlotte, NC 28241
10/12/98/E1
First Edition
P/N PS 01460
SAFETY INSTRUCTIONS
GROUND FAULT CIRCUIT INTERRUPTER
For additional protection against the hazards of electrical shock
from defective attachments such as tools, cords and cables,
consider the use of a GFCI (Ground Fault Circuit Interrupter). The
GFCI is a device that interrupts electricity from either utility or a
generator by means of a special type of circuit breaker if a fault to
ground occurs. EXAMPLE: If a person is in contact with the
ground and touches a defective tool or bare wire from a damaged
cord set, he may receive an electrical shock. The GFCI would
sense this shock and interrupt the electrical supply before the
person is seriously injured.
A GFCI can be used with generators that have the neutral wire
internally grounded to the frame properly grounded to the earth.
The GFCI will not work on generators that do not have the neutral
grounded to the frame. Homelite generators have neutral wire
ground to frame.
WARNING
The GFCI may not function unless the generator is properly
grounded. Follow the correct grounding procedure specified
below.
NOTE:
Situations exist where the GFCI will not afford any protection
against the hazards of electrical shock. EXAMPLE: If a person
touches two or more conductors from a damaged cord set and is
not in direct contact with the ground, he may receive a shock.
Since there is no path to ground for a current to flow through, the
GFCI will not operate and serious injury may result.
The GFCI is merely an added safety precaution. There are no
substitutes for good safety precautions, correct electrical practices and proper maintenance of cords, electrical equipment and
connections.
GROUNDING THE GENERATOR
The wing nut and ground terminal on the frame must always be
used to connect the generator to a suitable ground source. The
ground path should be made with #8 size wire. Connect the terminal
of the ground wire between the lock washer and the wing nut, and
tighten the wing nut fully. Connect the other end of the wire securely
to a suitable ground source.
The National Electric Code contains several practical ways in which
to establish a good ground source. Examples given below illustrate
a few of the ways in which a good ground source may be established.
GROUNDING THE GENERATOR-Cont'd
A metal underground water pipe in direct contact with the earth for
at least 10 feet can be used as a grounding source. If an underground pipe is unavailable, an 8 foot length of pipe or rod may be
used as the ground source. The pipe should be 3/4 inch trade size
or larger and the outer surface must be norcorrosive. If a steel or
iron rod is used it should be at least 5/8 inch diameter and if a
nonferrous rod is used it should be at least 1/2 inch diameter and
be listed as material for grounding. Drive the rod or pipe to a depth
of 8 feet. If a rock bottom is encountered less than 4 feet down, bury
the rod or pipe in a trench. All electrical tools and appliances
operated from this generator, must be properly grounded by use of
a third wire or be “Double Insulated”. It is recommended that:
1. Use electrical devices with 3 prong power cords.
2. Use an extension cord with a 3 hole receptacle and a 3 prong
plus at opposite ends to ensure continuity of the ground
protection from the generator to appliance.
We strongly recommend that all applicable Federal, State and local
regulations relating to grounding specifications be checked and
adhered to.
LINE TRANSFER SWITCH
If this generator is used for standby service, it must have a transfer
switch between the utility power service and the generator. The
transfer switch not only prevents the utility power from feeding into
the generator, but it also prevents the generator from feeding out
into the utility company's lines. This is intended to protect a
serviceman who may be working on a damaged line. THIS INSTAL-
LATION SHOULD BE DONE BY A LICENSED ELECTRICIAN
AND ALL LOCAL CODES MUST BE FOLLOWED.
PREPARING FOR USE
ENGINE OIL
CAUTION
This engine crankcase is not filled with oil at the factory, so be
sure to fill it before operating the engine.
TO CHECK OIL LEVEL:
NOTE
When checking the oil be sure
the engine is level. Always
use a high quality detergent
oil with an API classification
of SE of SF. See engine manual for specific recommendations on SAE viscosity grade,
oil capacities and oil change
intervals.
Do not mix oil with gasoline.
RECOMMENDED FUEL: Use any gasoline intended for automotive use. For normal use, purchase fuel that can be used in 30 days.
This will assure fuel freshness and volatility tailored to the season.
Consult engine operating and maintenance instructions for use of
oxygenated fuels.
WHEN FILLING TANK:
1. Clean area around fuel cap and loosen cap slowly. Rest the
cap on a clean surface.
2. Carefully put fuel into the tank, filling to approximately 1/4 inch
(5mm) of the top. Avoid spillage.
3. Immediately replace cap and hand tighten. Wipe up any fuel
spillage.
DO NOT OPERATE ENGINE IF GASOLINE IS SPILLED. AVOID
CREATING ANY IGNITION UNTIL THE GASOLINE HAS EVAPORATED.
STARTING AND STOPPING
Check engine oil before starting
1. Remove the load by unplugging any plugs from receptacles.
2. Move the “OFF-ON” switch to “ON” position.
3. Move choke lever to the “CHOKE” position (see illustration).
4. Grasp starter firmly and pull slowly until resistance is felt.
Then pull rapidly. If engine fails to start on first pull, open
choke slightly and repeat.
5. When engine starts, open choke gradually to the “RUN”
position.
6. To stop: Move “OFF-ON” switch to “OFF” position.
NOTE:
If the engine is warm, set choke to "RUN" position.
OPERATION
LOAD APPLICATION
The continuous duty rating should not be exceeded for long
periods of time. Always be sure that the voltage, amperage and
frequency requirements of the equipment to be used can be
satisfied by the generator. To avoid damage, the generator
should not be operated at the intermittent rating for more than 10
minutes out of every hour.
RUN
OFFON
CHOKE
CABLE SIZE
Equipment damage can result from low voltage. To prevent
excessive voltage drop between the generator and the equipment, the cable or extension cord should be adequate for the
length used.
CONTROL PANEL
The generator is equipped with one 120 volt 15 amp, parallel slot,
U-ground, NEMA 5-15R duplex receptacle and one resettable
thermal type circuit breaker. The circuit breaker protects against
severe overloads or short circuits. If the circuit breaker trips, the
cause should be determined and corrected prior to continuing
use.
NEVER EXCEED THE RATING OF A RECEPTACLE.
MAINTENANCE
ENGINE:
See Engine Manual for Maintenance Procedures.
STORAGE
When the generator is not used for a long period, it should be
stored properly. Before storing, proceed as follows:
1. Drain the fuel tank completely.
2. Start the engine and allow it to run until fuel in the carburetor
and fuel lines have been used.
3. Remove the spark plug and put 3 to 5 cc of oil into the spark
plug hole in the cylinder head.
120V
RECEPTACLES
CIRCUIT
BREAKERS
GENERATOR:
Keep all air vents clear.
Keep clean.
Periodically check all fasteners and tighten.
4. Install the spark plug and slowly pull the starter handle a few
times to distribute the oil.
5. Retighten all bolts and nuts.
6. Clean the exterior surface of the generator and apply a rust
inhibitor.
7. Store the generator in a dry, well ventilated place.
3
TROUBLE SHOOTING
NOTE: Servicing generators may require use of specialized tools
and electronic equipment. If these solutions do not solve the
problem contact your authorized servicing dealer.
PROBLEM: Engine will not start:
1. Is the engine switch ON?
2. Is there fuel in the tank?
3. Is there spark at the spark plug?
A) Remove the spark plug cap. Clean any dirt from around
the plug base, then remove the spark plug.
B) Install the spark plug in the plug cap.
C) Turn the engine switch on.
D) Grounding the electrode to any engine ground, pull the
recoil starter to see if sparks jump across the gap.
E) If there is no spark, replace the plug.
F) With new plug installed repeat “D” above.
G) If okay, reinstall plug and start engine according to instruc-
tions. If not consult a Servicing Dealer.
H) If engine still does not start, take it to a Servicing Dealer.
PROBLEM: Generator has no output.
1. Reset circuit breakers
2. Check cord sets and extension cords.
3. Consult Servicing Dealer.
HOMELITE PRODUCT- LIMITED WARRANTY
John Deere Consumer Products, Inc. warrants to the original retail purchaser that this Homelite® Product is free from defects in material
and workmanship and agrees to repair or replace at John Deere Consumer Products, Inc.'s discretion any defective Product free of charge
within these time periods from the date of purchase:
• One year, if the Product is used for personal, family, or household use;
• 90 days, if the Product is used for any other purpose, such as commercial or rental use.
This warranty is not transferable and does not cover damage resulting from other than defects in material or workmanship, or damage
caused by unreasonable use, including the failure to provide reasonable and necessary maintenance. Also, the warranty obligations
do not apply to conditions resulting from misuse, alteration or accident. In addition, this warranty does not cover general check-ups on
electrical equipment, tune-ups on gasoline engines or replacement of non-defective parts (such as electrical brushes, cables, plugs, spark
plugs, filters, starter ropes, etc.) that may wear and need to be replaced with reasonable use within the warranty period or which may require
replacement in connection with normal maintenance. This warranty applies only to products sold within the United States of America,
the District of Columbia, Canada, Mexico, the Commonwealth of Puerto Rico, the Virgin Islands, Guam, the Canal Zone, or American
Samoa.
SAVE YOUR SALES SLIP
Proof of purchase in the form of your dated sales receipt, cash register slip, etc. showing the serial number and the model of your Product
will be required before our dealers can perform warranty service on the Product. You must at your own expense arrange to deliver or ship
the Product for warranty repairs and arrange for pickup or return of the Product after repairs have been made.
This warranty does not apply to any trade accessory, engine or electric motor which is separately warranted by another manufacturer and
not manufactured by John Deere Consumer Products, Inc.
THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. ANY IMPLIED WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE, MERCHANTABILITY OR OTHERWISE, APPLICABLE TO THIS PRODUCT, SHALL BE LIMITED IN
DURATION TO THE DURATION OF THIS LIMITED WARRANTY. JOHN DEERE CONSUMER PRODUCTS, INC. SHALL NOT BE LIABLE
FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY
NOT APPLY TO YOU. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
HOW TO OBTAIN WARRANTY SERVICE
Warranty service can be obtained from a Homelite
first with the Homelite® dealer from whom you purchased the Product, or call the following number for the name and location of the nearest
dealer providing warranty service: 1-800-242-4672 - United States, Puerto Rico, and Virgin Islands. In Canada, you may also obtain this
information from our Sales Office: HOMELITE CANADA LTD, 1850 55TH AVENUE, LACHINE, QUEBEC, CANADA H8T-3J5 or call 1-
800-363-5715. FOR WARRANTY SERVICE INFORMATION OUTSIDE THE USA AND CANADA, PLEASE CONTACT YOUR LOCAL
HOMELITE
John Deere Consumer Products, Inc. will not make any reimbursements for warranty service, except to Homelite
to make warranty repairs. You must present your sales receipt when making any claim for warranty service.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
This product is certified in Canada to comply with radio interference standards. Replace spark plug with resistor spark
plug only.
This warranty is given by John Deere Consumer Products, Inc., Post Office Box 7047, Charlotte, North Carolina 28241.
An extended warranty is available for most Homelite
®
DEALER.
®
dealer authorized to make warranty repairs. If you need warranty service, check
®
dealers authorized
®
products. Contact an authorized Homelite® servicing dealer.
4
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.