Installation Ceiling Rose:
Do not use the HE-206 Ceiling Rose with low voltage lighting transformers,
fluorescent bulbs, or energy saving lighting, incorrect installation may damage the converter. In case of any doubt consult a competant electrical installer
For use with 1 gang incandescent lights, indoor use only.
Light Switch
HE-307
INSTALLATION WARNINGS:
BEFORE COMMENCING INSTALLATION
ISOLATE YOUR MAINS ELECTRIC SUPPLY
Read the instructions care fully before starting the installation process and keep them for future reference. If you are in any doubt on the installation process, consult a qualified electrician.
This product should be installed in accordance with the relevant sections of the building regulations code, and the current edition of the IEE Wiring Regulations (BS 7671:Requirements for electrical installations) and appropriate statutory regulations.
Do not install ceiling receivers on lighting circuits used to supply other products such as extractor fans and shaver socket outlets. Do not exceed the Maximum Power Rating of 100W, Incandescent lighting only
Ceiling Rose
HE-206
1: Isolate the mains supply, then remove the existing ceiling rose.
2: Attach the HE-206 ceiling rose using the
screws provided.
3: Wire the mains cable to the HE-206 Ceiling Rose as per the diagram opposite, making sure the Live and neutral wires are correctly connected. If required a breakable tab on the base can be removed.
4: Connect the all switch to the ceiling rose, making sure that the switch is zero voltage.
Com
1Way
Ceiling Rose
Light Switch
230 ~ 50Hz
SWITCH CABLE
ZERO VOLTAGE
As of1 April 2004, new installations in the UK should be wired using the EU harmonised colours for the supply conductors: New colours:  BROWN = Live  BLUE = Neutral Earth = Yellow/Green Old colours:  RED = Live BLACK = Neutral The old colours will cease from April 2006.
Electrical installations in bathrooms, kitchens, gardens, floor and heating systems, swimming pools, saunas and extra-low voltage lighting are classed as special installations and must be certified and conforming to Part P, requirements of BS 7671:2001 and appropriate statutory regulations. Contact your local Building Regulation authority if required.
5:Make sure all the cables are connected correctly and securely fastened.
6: Now pair the HE-206 bayonet ceiling rose with a HomeEasy Remote control HE-100, HE-200, HE-300 or HE-102 (Not Included).
See Pairing and Deleting Remote Control.
7: Replace the ceiling rose cover making sure no wires are caught between the switch and the wall. Do not over tighten as this could crack or distort the cover. .
230~240V
Live
Nutral
Earth
Installation Light Switch:
Pairing/Deleting With Remote Control:
Changing Battery:
Using a small flat screwdriver remove the front cover by placing the screw driver in the location notch on the bottom part of the rocker cover and unclip the cover.
Once the location for the switch has been selected, the wall switch can be stuck or screwed to the wall
WARNING: Attaching the HE-307 to a metallic surface will reduce the operating distance.
Self Adhesive Tabs: 1: To stick the HE-307 to the wall, clean the surface of all loose material and
grease using an appropriate cleaner (an alcohol based cleaner is recommended for tiled surfaces). When the surface is dry, remove the backing tabs on the double sided sticky pads located on the back of the wall switch and press firmly against the wall.
To screw the unit to the wall:
2. Using the backing bracket as a template
mark and drill two holes and fix the bracket
UP
securely using the appropriate screws and wall plugs (included), make sure the arrow faces up.
Switching On/Off /Dimming:
Remote Control:
On/Dim
(See pairing/deleting with remote control)
On: Press on button OFF: Press Off button
Off
Up to Six remote control Light switch's or HomeEasy remote controls (not included), can be paired with a single Remote Control Ceiling Rose. To program the Remote Control Ceiling Rose install the unit as per the instructions (See Installation), now press the "Learn" button located inside the ceiling rose cover.
On/Dim
LED
LEARN
Off
Pairing with Light Switch:
The LED will start to flash, now press the selected "On" button on the remote control, the LED will stop flashing. The units are now paired together. Place your selected light bulb (max 100W) into the Bayonet Ceiling Rose (BEC14/E27), you can test this by pressing the "ON/OFF" on the light switch
Deleting Light Switch:
To delete a remote control that has been paired with the Remote Control Ceiling Rose, simply press the "Learn" button. The LED will start to blink; press the "Off" button on the remote control, the LED will blink twice to confirm that the remote control has been removed from the memory of the Ceiling Rose.
Resetting Ceiling Rose:
To delete all the remote control units from the memory of the HE-206 Ceiling Rose, hold the "Learn" button for more than 6 seconds, the LED will start to blink continuously. Press the learn button again, the LED will blink twice to confirm the deletion of all remote controls form the memory of the Ceiling Rose.
Product Specification:
Warning: Never Exceed the Product Specification
Using a small flat screwdriver remove the front cover by placing the screw driver in the location notch on the bottom part of the rocker cover and unclip the cover.
Battery
Replace the battery with a new CR2032 battery (Byron SX100), making sure the polarity is correct, then replace the front cover.
Help Section :
RF Range: The radio signals operating distance is reduced when the signal has
to pass through walls. The radio signals achieve a range of 30m inside a building; this can be reduced depending on the type of material
BRICK
PLASTICS
Range
Reduction Guide:
10 - 15%
CONCRETE
40- 80%
METAL
90%
GLASS
5 - 15%
10 - 40%
TIMBER
10 - 40%
Dimming: Press "On" and then press "On" again, the Ceiling Rose unit will
now start to dim, press "On" to select the required level. To switch "Off", press off as normal.
Standard Light Switch: On/Off: Switch on and off as normal. Dimming: Switch On, Off and On again. The converter will now start to dim, to
select the required level switch the light Off and On.
Ceiling Rose: HE-206 Power: 230V~50Hz Max Load:100W BEC14/E27 (Incandescent Lighting) Internal Fuse: 2A, 130 degrees Celsius Range: 30 Metres (Open Distance) Frequency: 433.92MHz Indoor Use Only
Remote Control: HE-307 Battery: 3v Cr2032 Range: 30 Metres (Open Distance) Frequency: 433.92MHz Indoor Use Only
Contact:  Helpline: 0845 2301 231
Contact Details:
C H Byron 34, Sherwood Rd Aston Fields Bromsgrove B60 3DR
Tel: 0845 2301231 Fax: 01527 557701 Web: www.chbyron.com E-mail: support@chbyron.com
433MHz
R&TTE
APPROVED
A
IRL
B DK FIN
F
D
GR
LT
CH Byron Electrical United Kingdom. www.chbyron.com
I
L
NL
P E S
0560
UK BG CZ EST
H IS
LV
SLO CH
RO
M N
SK
PL
Loading...