HoMedics WFL-ISL User Manual

Dirección postal: HoMedics
Consumer Relations Service Center Dept. 168 3000 Pontiac Trail Commerce Township, MI 48390
Correo electrónico: cservice@homedics.com
Teléfono: 800-466-3342
ARANTÍA LIMITADA POR UN AÑO
G
H de obra por un plazo de un año a partir de la fecha de compra original, con las siguientes excepciones. HoMedics garantiza que sus productos no tendrán defectos de material ni de mano de obra bajo condi­ciones de uso y servicio normales. Esta garantía se extiende únicamente a consumidores y no a dis­tribuidores.
ara obtener servicio para su producto HoMedics, envíe por correo el producto y su recibo de compra
P
echado (como comprobante de compra), con franqueo pago, a la siguiente dirección:
f HoMedics Consumer Relations
Service Center Dept. 168 3000 Pontiac Trail Commerce Township, MI 48390
No se aceptarán pagos contra entrega. HoMedics no autoriza a nadie, incluyendo, pero sin limitarse a, distribuidores, posteriores consumidores
compradores del producto a un distribuidor, o compradores remotos, a obligar a HoMedics de forma alguna más allá de las condiciones aquí establecidas. La garantía de este producto no cubre daños cau­sados por uso inadecuado o abuso, accidente, conexión de accesorios no autorizados, alteración del producto, instalación inadecuada, reparaciones o modificaciones no autorizadas, uso inadecuado de la fuente de energía/electricidad, cortes de energía, caída del producto, funcionamiento incorrecto o daño de una pieza de funcionamiento debido al no cumplimiento del mantenimiento recomendado por el fab­ricante, daños durante el transporte, robo, descuido, vandalismo, condiciones climáticas, pérdida de uso en el período durante el cual el producto está en una instalación de reparación o a la espera de piezas o reparación, o cualquier otra condición, sin importar cual sea, que se encuentre fuera del control de HoMedics.
Esta garantía es válida únicamente si el producto es comprado y operado en el país en el cual se com­pró el producto. Un producto que requiera modificaciones o adaptación para habilitar su funcionamiento en cualquier país que no sea aquél para el que fue diseñado, fabricado, aprobado y/o autorizado, o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía.
LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA. NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA, INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA OBLIGACIÓN POR PARTE DE LA COMPAÑÍA CON RESPECTO A PRODUC­TOS CUBIERTOS POR ESTA GARANTÍA. HOMEDICS NO TENDRÁ RESPONSABILIDAD ALGUNA POR NINGÚN DAÑO INCIDENTAL, CONSECUENTE NI ESPECIAL. BAJO NINGÚN CONCEPTO ESTA GARANTÍA REQUERIRÁ MÁS QUE LA REPARACIÓN O CAMBIO DE ALGUNA PIEZA O PIEZAS QUE SE HALLEN DEFECTUOSAS DENTRO DEL PERÍODO DE VIGENCIA DE ESTA GARANTÍA. NO SE EFECTUARÁN REEM­BOLSOS. SI NO HAY PIEZAS DE REPUESTO DISPONIBLES PARA LOS MATERIALES DEFECTUOSOS, HOMEDICS SE RESERVA EL DERECHO DE REALIZAR SUSTITUCIONES EN VEZ DE REPARAR O CAM­BIAR.
Esta garantía no se extiende a la compra de productos abiertos, usados, reparados, embalados otra vez y/o abiertos y vueltos a cerrar, incluyendo entre otras cosas la venta de dichos productos en sitios de remate por Internet y/o la venta de dichos productos por revendedores o mayoristas. Todas y cada una de las garantías cesarán y terminarán inmediatamente con respecto a cualquier producto o pieza del mismo que estén reparados, cambiados, alterados o modificados sin el consentimiento previo explícito y por escrito de HoMedics.
Esta garantía le pr cionales que pueden variar de un país a otro. Debido a las regulaciones de ciertos países, es posible que algunas de las limitaciones y exclusiones no se apliquen en su caso.
oporciona derechos legales específicos. Es posible que usted tenga derechos adi-
Por más información con respecto a nuestra línea de productos en los EE.UU.,
7 HoMedic
00
©2
visítenos en: www.homedics.com
s, Inc. y sus compañías afiliadas, reservados todos los derechos. HoMedics
una marca registrada de HoMedics, Inc. y sus compañías afiliadas. Envirascape™ es una marca
comercial de HoMedics Inc. y sus compañías afiliadas. Reservados todos los derechos.
IB-WFLISL
R
ILLUMINATED TABLETOP RELAXATION FOUNTAIN
TM
ISLAND GARDENS
El Manual en
®
s
e
espanol empieza en la pagina 9.
Instruction Manual and Warranty Information
WFL
-ISL
The soothing sounds of nature
Thank you for purchasing EnviraScape, HoMedics’ tabletop relaxation fountain. This, like the entire HoMedics product line, is built with high-quality craftsmanship to provide you years of dependable service. We hope that you will find it to be the finest product of its kind.
EnviraScape enables you to create an all-encompassing environment with sound. The sound of flowing water enhances your environment by releasing negative ions, and promoting relaxation. Only EnviraScape offers you the luxury of these vital benefits with its creative design which adds beauty to any indoor environment.
EnviraScape Features
• Innovative, artistic design enhances the environment at home or at work.
• Special effect lighting illuminates fountain for a more dramatic effect.
• The soothing sound of cascading waters create a stress free ambiance.
• Improves concentration by masking distractions so you can stay focused.
• Durable electrical water pump can be operated from any indoor electrical outlet.
• Convenient tabletop size-fountain measures
9.25" L x 3.88" W x 12.45" H.
IMPORTANT SAFETY INSTRUCTIONS:
When using an electrical appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING
DDAANNGGEER
• Always unplug the appliance from the electrical outlet immediately after using and before cleaning.
• Do not reach for an appliance that has fallen into water. Unplug it immediately
Do not place or store appliance where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid.
Do not connect to any voltage other than that shown on the pump. Do not pump flammable liquids.
• Do not use water above 86
R
- To reduce the risk of electric shock:
.
o
Fahrenheit.
CAUTION: The pump must be completely submerged in water. If the pump is making noises, most likely it is not completely submerged in water.
CAUTION: Only set the fountain and fountain parts on waterproof surfaces
WWAARRNNIINNG
• An appliance should never be left unattended when plugged in. Unplug from outlet when not in use and before putting on or taking off parts or attachments.
• Close supervision is necessary when this appliance is used by or near children, invalids or disabled persons.
• Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by HoMedics; specifically any attachments not provided with the unit.
• Never operate this appliance if it has a damaged cord, plug, pump, cable or housing. If it is not working properly, if it has been dropped or damaged, return it to Homedics Service Center for examination and repair.
• Keep cord away from heated surfaces.
• Never drop or insert any object into any opening.
• Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
• Do not carry this appliance by power cord or use cord as handle.
• To disconnect, remove plug from outlet.
• This appliance is designed for indoor use only. Do not use outdoors.
G
- To reduce the risk of burns, fire, electric shock or injury to persons:
SAVE THESE INSTRUCTIONS
Caution –
• Never leave the appliance unattended, especially if children are present.
• Never cover the appliance when it is in operation.
• This unit should not be used by children without
adult supervision.
• Connect the pump with the proper voltage as indicated
on the pump label.
• Always keep the cord away from high temperature and fire.
• Unplug the pump from power source before cleaning,
maintenance or disassembling.
• To get the best flowing effect, product must be placed on a flat surface and should never be placed on an electrical appliance.
• Never let pump run dry, as this will shorten life of the pump.
• Do not lift, carry, hang, or pull the pump by the power cord.
• Operate with tap or distilled water only.
• Operate pump completely submerged for proper cooling.
• The electrical cord of this product cannot be replaced. If it sustains
damage, you must stop using this product immediately and return it to the HoMedics Service Center for repair. (See the warranty section for HoMedics address.)
• Disconnect the appliance from outlet before putting hands
into water.
Please read all instructions carefully before operating.
2
3
Assembly and Instructions for Use
1. Unpack the product. Wipe off dust with a damp cloth.
2. Familiarize yourself with the pump. The pump speed is controlled by the switch located at the front of the pump. The speed is indicated by a plus (+) and minus (-) sign. To increase the speed, move the switch slowly to the left in the direction of the plus sign. You will hear a click as the switch moves to each speed level. At its highest speed level, the switch will cease to move any further. To decrease the pump speed, move the switch to the right toward the minus sign. Similarly, at its lowest speed, the switch will cease to move any further. (Fig. 1)
NOTE: It is recommended the pump be set at its highest speed during assembly
and later adjusted to a lower setting if desired. Be sure to unplug the pump before adjusting the speed setting.
. Attach the Adaptor to the power cord. (Fig. 6)
9
10. Plug the cord into 120V household outlet. The fountain is controlled by a switch located on the power cord. If pump does not operate, rotate in-line switch once to turn “on” and once to turn “off”.
Note: Ensure that the electrical cord loops below the electrical outlet to
form a “Drip Loop”. This will prevent water from running down the electrical cord into the electrical outlet. (Fig. 7)
Figure 4
To p
Figure 6
To p
Attention: In order to get
best results, please operate pump completely submerged. Keep the water
Figure 1
Minimum Water Level
Flow Control Lever (+) faster water output (-) slower water output
level above the minimum water level ALL THE TIME.
3. Insert the waterproof light into the light clip located inside the base (Fig. 2) so that lights are facing upwards.
4. Insert the black tube attached to the fountain top into the round opening of the pump. (Fig. 3)
5. Fill the base with 20 oz. of clean water. Water level should not rise above support posts. NOTE: We recommend distilled water to prevent mineral build-up.(Fig.4)
6. Place fountain top onto base so that it sits flat. Run the pump power cord out
through the cord slot at the back of the fountain. (Fig. 4)
7. Next attach the four Leaf Cups by inserting the tab, located at the back of each
Leaf Cup, into its corresponding notch on the fountain top. Leaf Cups should attach to fountain securely. (Fig. 5)
8. Arrange Glass Stones provided on fountain top platform as desired. (Fig. 6)
Figure 2
Base
Figure 3
op
T
Black Tube
Water
Support Posts
Figure 5
2nd Leaf Notch
2nd Leaf Cup
Bottom Leaf Notch
Bottom Leaf Cup
Cord Slot
Pump
Base
Glass Stones
Top Leaf Notch
Top Leaf Cup
3rd Leaf Notch
3rd Leaf Cup
T
ab
Switch
Platform
Base
Adaptor
Light Clip
Waterproof Light
Base
Pump
4 5
eaf Cup
L
Loading...
+ 5 hidden pages