HoMedics CM50B User Manual

Cool Mist
Ultrasonic Humidifier
Instruction Manual and Warranty Information
HUM-CM50
IMPORTANT SAFETY INSTRUCTIONS:
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
DANGER
• Always unplug the appliance from the electrical outlet immediately after using and before cleaning.
• DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
• DO NOT use while bathing or in shower.
• DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
• DO NOT place in or drop into water or other liquid.
• NEVER use pins or other metallic fasteners with this appliance.
• Keep dry – DO NOT operate in a wet or moist condition.
• DO NOT use water above 30˚ Celsius.
WARNING
SHOCK OR INJURY TO PERSONS:
• An appliance should never be left unattended when plugged in. Unplug from outlet when not in use and before putting on or taking off parts or attachments.
• Close supervision is necessary when this appliance is used by or near children, invalids or disabled persons.
• Use this appliance only for its intended use as described in this manual.
• NEVER operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return it to HoMedics' Service Center for examination and repair.
– TO REDUCE THE RISK OF ELECTRIC SHOCK:
- TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC
2
• Keep cord away from heated surfaces.
• NEVER drop or insert any object into any opening.
• DO NOT operate where aerosol (spray) products are being used or where oxygen is being administered.
• Always place the humidifier on a firm, flat, level surface.
• Please hold the water tank firmly with both hands when carrying a full tank of water.
• NEVER use humidifier in an environment where explosive gases are present.
• DO NOT place the humidifier near heat sources, such as a stove and do not expose the humidifier to direct sunlight.
• DO NOT carry this appliance by the power cord or use cord as handle.
• To disconnect, turn all controls to the "OFF" position, then remove plug from outlet.
• This appliance is designed for personal, non-professional use only.
• DO NOT use outdoors. For indoor use only.
• DO NOT overfill with water.
• Children should be supervised to ensure they do not play with the appliance.
• Unplug the appliance during filling and cleaning.
SAVE THESE INSTRUCTIONS
CAUTION
BEFORE OPERATION.
• Never cover the appliance when it is in operation.
• Always keep the cord away from high temperature and fire.
• Perform regular maintenance of the Ultrasonic Nebulizer.
• Avoid contact with detergent to your mouth and eyes. If contact occurs, use clean water to wash immediately. If serious, contact poison control or seek medical treatment.
• Never use detergent to clean the Ultrasonic Nebulizer that is not recommended by the manufacturer.
• Never scrape the Ultrasonic Nebulizer with a hard object to clean.
– PLEASE READ ALL INSTRUCTIONS CAREFULLY
3
Operation and Maintenance
• Do not repair or adjust the unit. Servicing must be performed by professional or qualified personnel.
• Do not operate any appliance with an aging, knotted or damaged cord or plug, the replacement must be performed by the manufacturer, service center or qualified professional personnel.
• Stop use if there is an unusual noise or smell. Servicing should be performed by qualified personnel only.
• Humidifier should be unplugged when not in use for a long period of time.
• Do not touch the water in the main unit or the parts in the water when the unit is on.
• Never operate unit without water in the tank. Only use water in the tanks.
• Never add any additive to the water that is not produced or under the supervision of the manufacturer.
• Do not wash, adjust or move the humidifier without first unplugging the unit from its electrical outlet.
• Keep the appliance out of reach from children. Do not allow children to use the appliance without supervision.
4
Unique Features and Specifications
Ultrasonic Technology
This humidifier uses ultrasonic high frequency technology to convert the water into 1-5 million super particles that are dispersed into the air evenly. These particles then combine with the ions generated by the humidifier to moisten the air.
Oscillating Head The humidifier features a motorized nozzle that oscillates 120°. The oscillating head can also be stopped at any point in the oscillation cycle to target the mist in a specific direction.
Night Light A useful night light feature is included for your convenience.
Auto Shut Off Protection When the tank is empty the unit will shut off automatically.
Overheat Protection
This humidifier is equipped with a non-resettable fuse in case of overheating. If the non-resettable fuse has been activated, operation cannot be resumed. The fuse will need to be replaced by an authorized service personnel.
Ultrasonic Nebulizer The humidifier utilizes special spray techniques and the ultrasonic nebulizer is easy to clean for lifetime use.
Voltage 240V / 50Hz
Watts 23
Tank Capacity
3.78 litres
5