HoMedics BPW-201 Ver. B User Manual

Automatic Wrist
Blood Pressure Monitor
BPW-201 Ver. B
El manual en español empieza en la página 38
1
TABLE OF CONTENTS
INTRODUCTORY INFORMATION:
Important Product Notices and
Safety Instructions .......................................... 3
About Blood Pressure ..................................... 5
Blood Pressure Standard ................................ 6
How This Blood Pressure
Monitor Works .................................................. 8
USAGE INFORMATION:
Name/Function of Each Part ........................... 9
Display Explanations ..................................... 10
Installing Batteries ........................................ 12
Date & Time Set Procedure ........................... 14
Applying the Cuff ........................................... 15
Correct Measurement Posture ..................... 17
Measurement Procedure ............................... 18
2
Risk Category Index ...................................... 22
Irregular Heartbeat Detector (IHB) .............. 23
Recalling Values from Memory ..................... 25
Clearing Values from Memory ...................... 26
Important Notes Regarding Your
Blood Pressure Measurement ...................... 27
Care, Maintenance & Cleaning ..................... 28
Potential for Electromagnetic
Interference .................................................... 30
Electromagnetic Compatibility (EMC) .......... 31
Troubleshooting ............................................. 33
Specifications ................................................ 34
5 Year Limited Warranty ................................ 36
3
IMPORTANT PRODUCT NOTICES AND SAFETY INSTRUCTIONS
When using your blood pressure monitor, basic precautions should always be followed. Please read and follow all instructions and warnings before using this product. Save these instructions for future reference.
Please note that this is a home healthcare product only and it is not intended to serve as a substitute for the advice of a physician or medical professional.
This device uses the oscillometric method to measure systolic and diastolic blood pressure, as well as heart rate.
Do not use this device for diagnosis or treatment of any health problem or disease. Measurement results are for reference only. Consult a healthcare professional for interpretation of blood pressure measurements. Contact your physician if you have or suspect any medical problem. Do not change your medications without the advice of your physician or healthcare professional.
This product is not suitable for people with arrhythmias. This device may have difficulty determining the proper blood pressure for pregnant women and for individuals with irregular heartbeat, diabetes, poor circulation of blood, kidney problems or for users who have suffered from a stroke.
Excessive use may result in blood flow interference,
which is likely to cause uncomfortable sensations, such as partial subcutaneous hemorrhage, or temporary numbness to your wrist. In general these symptoms should not last long. However, if you do not recover in time, please seek advice from a medical professional.
4
Consult your physician before measuring blood pressure at the wrist if you have any of the following conditions: Severe hypertension, severe diabetes, severe arteriosclerosis, severe kidney disease or vascular disease that may compromise circulation.
The pulse display is not suitable for checking the frequency of heart pacemakers.
Electromagnetic interference: The device contains sensitive electronic components. Avoid strong electrical or electromagnetic fields in the direct vicinity of the device (e.g. mobile telephones, microwave ovens). These may lead to temporary impairment of measurement accuracy.
Consider the electromagnetic compatibility of the device
(ex. power disturbance, radio frequency interference etc.) Please use this device indoors only.
Use blood pressure monitor only for its intended use.
Do not wrap the cuff around body parts other than your wrist.
Not for use by or on persons under the age of 18.
Do not use this device on infants, children, or those who
cannot express their own intention.
Use only 1.5V “AAA” alkaline batteries for power supply.
Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultatory method, within the limits prescribed by the American National Standard, Manual, electronic, or automated sphygmomanometers.
5
ABOUT BLOOD PRESSURE
What is Blood Pressure?
Blood pressure is the pressure exerted on the artery walls while blood flows through the arteries. The pressure measured when the heart contracts and sends blood out of the heart is systolic (highest) blood pressure. The pressure measured when the heart dilates with blood flowing back into the heart is called diastolic (lowest) blood pressure.
Why Measure Your Blood Pressure?
Among today’s various health problems, those associated with high blood pressure are very common. High blood pressure dangerously correlates with cardiovascular diseases. Therefore, blood pressure monitoring is important for identifying those at risk.
6
BLOOD PRESSURE STANDARD
The table below contains defined levels for hypertension that are publicly available from the National Heart Lung and Blood Institute at the U.S. National Institutes of Health (NIH) (http://www.nhlbi.nih.gov/health/dci/Diseases/Hbp/HBP_ WhatIs.html). Users can compare their own blood pressure readings against these defined levels to determine if they may be potentially at increased risk.
This table is applicable to most adults aged 18 and older. Blood pressure tends to go up and down, even in people
who normally don’t have high readings. If your numbers stay above the “normal” range most of the time, you may be at increased risk and should consult your physician.
Although one can easily find where their own blood pressure readings fall on this table, this monitor comes equipped with a Risk Category Index that automatically compares each reading to the defined levels and provides a helpful cue if
Category Systolic (mmHg) Diastolic (mmHg) Normal Less than 120 and Less than 80 Prehypertension 120-139 or 80-89 High Blood Pressure Stage 1 140-159 or 90-99 Stage 2 160 or higher or 100 or higher
7
your reading falls into one of the stages that could potentially indicate increased risk. See page 22 for more information on this feature.
Please note that cues provided by this monitor are only intended to assist you in using this table. The table and cues are only provided for convenience to help you understand your non-invasive blood pressure reading as it relates to the NIH information. They are not a substitute for a medical examination by your physician. It is important for you to consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you may actually be considered to be at risk.
8
HOW THIS BLOOD PRESSURE MONITOR WORKS
This monitor uses innovative technology to detect your blood pressure. This technology enables the monitor to automatically inflate and deflate at the appropriate level for each individual. With one touch of a button, the cuff will automatically inflate to block the blood flow through your artery. Next, the deflation process starts. Please note that any muscle movement during inflation or deflation will cause measurement error. When measurement is complete, the monitor will display your systolic pressure, diastolic pressure, and pulse readings.
The monitor automatically finds where your measurement results fall on the NIH’s National Heart Lung and Blood Institute’s table and provides a cue if your reading falls into one of the stages that could potentially indicate increased risk. See page 22 for more information on this feature.
The appearance of the
icon indicates that a pulse irregularity consistent with an irregular heartbeat was detected during measurement. Refer to page 23 for more information on the Irregular Heartbeat Detector.
9
NAME/FUNCTION OF EACH PART
Other Accessories Included:
2 “AAA” size, 1.5V alkaline batteries Carrying case
MEMORY RECALL Button
USER­SELECT Button
Wrist Cuff
Battery Cover
START/STOP
Button
DATE/TIME SET Buttons
LCD Display
10
DISPLAY EXPLANATIONS
VG. 3
AVG. 3
Systolic Pressure
Diastolic Pressure
Date/Time Indicator
Heart Rate
11
Display Symbols:
User 1: Appears when the monitor is operated by User 1. User 2: Appears when the monitor is operated by User 2.
Weak Battery Symbol: Appears when batteries should be
replaced.
Pulse Symbol: Shows the heart rate per minute. Irregular Heartbeat Detector: See page 23 for more
information.
Memory Average: Displays average of last 3 readings. Risk Category Index: See page 22 for more information.
Measurement Error: Wrap the cuff correctly and keep wrist
steady during measurement. Measure again.
Air Circuit Abnormality: Measure again. Pressure Exceeding 300 mmHg: Switch the unit off to clear,
then measure again.
Error Determining Measurement Data: Measure again. System Error: Measure again.
AVG.
3
If and any of the following letters and numbers appear in the area that systolic pressure should be displayed, an error has occured with your reading. See Troubleshooting section of this manual for more information.
12
INSTALLING BATTERIES
1. The battery cover is located along
the side of the monitor. Remove battery cover by pressing down and pulling away from the monitor.
2. Install batteries according to
the polarity indications inside the compartment (as shown in figure 2). Battery Type: 2
Alkaline LR03 “AAA” size
3. Insert the other battery,
according to the polarity indications inside the compartment (as shown in figure 3).
4. Replace the cover by inserting
it back into place.
1.
3.
4.
2.
13
Replace the batteries if:
• The weak battery symbol appears on the display.
• Nothing appears on the display when the power is
switched on.
As the supplied batteries are for test only, they may be discharged earlier than batteries you buy in stores. Replace all batteries at one time (as simultaneous set). Use only
1.5V “AAA” alkaline batteries. Remove batteries when unit is not in use for extended periods of time. Date and time will need to be reset if batteries are removed or replaced. Clean contacts on battery and in battery compartment with a soft dry cloth each time you install batteries.
Note: Batteries are hazardous waste. Do not dispose of them
together with the household garbage.
14
DATE & TIME SET PROCEDURE
1. To adjust the date/time, press the SET button
located on the top of the monitor.
2. The display will show a blinking number showing the
HOUR. Change the HOUR by pressing the
button.
Each press will increase the number by one in a cycling manner. Press the SET button
again to confirm
the entry, and the screen will show a blinking number representing the MINUTE.
3. Change the MINUTE, MONTH, DAY and YEAR as
described in Step 2 above, using the
button to
change the numbers and the SET button
to confirm
the entries.
Press the button
blinking HOUR
increasing HOUR
confirm the entry
repeat process to set MINUTE,
MONTH, DAY and YEAR
AVG. 3
15
APPLYING THE CUFF
1. Remove all watches, wrist jewelry, etc. prior to attaching
the wrist monitor. Clothing sleeves should be rolled up and the cuff should be wrapped around bare skin for correct measurements.
2. Apply cuff to left wrist with palm
facing up as shown in Fig. A.
3. Make sure the edge of the cuff is
about 1/4”~1/2” (1 cm) from the palm as shown in
Fig. B.
Fig. A
Fig. B
16
4. In order to ensure accurate
measurements, fasten the hook and loop strap securely around your wrist so there is no extra space between the cuff and the wrist as shown in Fig. C. If the cuff is not wrapped tight enough, the measurement values will not be accurate.
5. If your physician has diagnosed
you with poor circulation in your left arm, place the cuff around your right wrist as shown in Fig. D.
Note:
• This device should not be used when your wrist is
wounded or injured.
• If it is not possible to use the cuff on your left wrist,
it can also be used on your right wrist. However, all measurements should be made using the same wrist.
Fig. C
Fig. D
17
CORRECT MEASUREMENT POSTURE
1. Place your elbow on a table so that the
cuff is at the same level as your heart as shown in Fig. A. Relax your entire body, especially between your elbow and fingers. Note: Your heart is located slightly below your armpit.
2. If the cuff is not at the same level as
your heart or if you cannot keep your arm completely still throughout the reading, use a soft object such as a folded towel to support your wrist as shown in Fig. B.
3. Turn your palm upwards.
4. Sit upright in a chair, and take 5-6 deep
breaths.
5. Avoid leaning back while the measurement is being taken as shown
in Fig. C.
Fig. A
Fig. B
Fig. C
(X)
18
MEASUREMENT PROCEDURE
Important Notes:
• Position the monitor at the same level as your heart
during measurement to ensure accurate readings.
• Blood pressure changes with every heartbeat and is in
constant fluctuation throughout the day.
• Blood pressure measurement can be affected by the
position of the user, his or her physiologic condition and other factors. For greatest accuracy, wait 1 hour after exercising, bathing, eating, drinking beverages with alcohol or caffeine, or smoking to measure blood pressure.
• Before a measurement, it is suggested that you sit
quietly for 15 minutes as measurements taken during a relaxed state will have greater accuracy. You should not be physically tired or exhausted while taking a measurement.
• During the measurement, do not talk or move your
arm or hand muscles.
• See page 27 for additional notes regarding your
blood pressure measurement.
If you are using this blood pressure monitor for the first time, please remove the protective film from the screen.
19
1. Press the USER-SELECT button to choose User 1
or User 2.
2. With the cuff wrapped around your wrist, press the
START/STOP button. Do not start the measurement process unless the cuff is wrapped around
your wrist. All digits will light up, checking the display functions. The checking procedure will be completed after about 3 seconds.
/
AVG. 3
OR
AVG.
3AVG. 3
AVG. 3
AVG. 3
AVG. 3
/
START
STOP
20
3. After all symbols disappear, the display will show
“00”. The monitor is “Ready to Measure” and will automatically inflate the cuff to begin measurement. This cuff will then begin deflating as measurement continues.
Note: The monitor will re-inflate automatically if the system
detects that your body requires more pressure for measurement.
21
4. When the measurement is completed, the cuff will
deflate entirely and systolic pressure, diastolic pressure and pulse will be shown simultaneously on the LCD screen. The measurement is then automatically
stored into memory.
Note:
• This monitor automatically turns off approximately 1
minute after last operation. You may also press the START/STOP button to turn the unit off.
• To interrupt the measurement, you may press the
START/STOP button (recommended), M, USER­SELECT or DATE/TIME SET (
/
/ ) buttons. The
cuff will deflate immediately after a button is pressed.
22
RISK CATEGORY INDEX
This monitor comes equipped with a Risk Category Index that automatically compares each reading to defined levels established by the U.S. National Institutes of Health’s (NIH) National Heart Lung and Blood Institute as described earlier in this manual, and provides a helpful cue if your reading falls into one of the stages that could potentially indicate increased risk. No cue is given if the reading falls in the normal range as defined by NIH. Please note that cues provided by this monitor are only intended to assist you in using this table. The table and cues are only provided for convenience to help you understand your non-invasive blood pressure reading as it relates to the NIH information. They are not a substitute for a medical examination by your physician. It is important for you to consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you may actually be considered to be at risk.
(No Symbol)
Loading...
+ 53 hidden pages