HoMedics BPA-300 User Manual

BPA-300
El manual en español empieza en la página 34
Deluxe Automatic
Blood Pressure Monitor
derechos. HoMedics es una marca registrada de HoMedics, Inc. y sus
compañías afiliadas. TheraP™ y DK Technology™ son marcas
registradas de HoMedics Inc. y sus compañías afiliadas.
Reservados todos los derechos.
IB-BPA300-A
Por servicio o reparación, no devuelva esta unidad al distribuidor. Póngase en contacto con Relaciones con el Consumidor de HoMedics por el:
Correo: HoMedics, Inc. Service Center Dept. 168 3000 Pontiac Trail Commerce Township, MI 48390
Correo electrónico: cservice@homedics.com
Teléfono: 1-800-466-3342 Horario comercial: 8:30am a 5pm Hora del Este De lunes a viernes
NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA OBLIGACIÓN POR PARTE DE LA COMPAÑÍA CON RESPECTO A PRODUCTOS CUBIERTOS POR ESTA GARANTÍA. HOMEDICS NO TENDRÁ RESPONSABILIDAD ALGUNA POR NINGÚN DAÑO INCIDENTAL, CONSECUENTE NI ESPECIAL.
BAJO NINGÚN CONCEPTO ESTA GARANTÍA REQUERIRÁ MÁS QUE LA REPARACIÓN O CAMBIO DE ALGUNA PIEZA O PIEZAS QUE SE HALLEN DEFECTUOSAS DENTRO DEL PERÍODO DE VIGENCIA DE ESTA GARANTÍA. NO SE EFECTUARÁN REEMBOLSOS. SI NO HAY PIEZAS DE REPUESTO DISPONIBLES PARA LOS MATERIALES DEFECTUOSOS, HOMEDICS SE RESERVA EL DERECHO DE REALIZAR SUSTITUCIONES EN VEZ DE REPARAR O CAMBIAR.
Esta garantía no se extiende a la compra de productos abiertos, usados, embalados otra vez y o abiertos y vueltos a cerrar, incluyendo entre otras cosas la venta de dichos productos en sitios de remate por Internet y/o la venta de dichos productos por revendedores o mayoristas.
Todas y cada una de las garantías cesarán y terminarán inmediatamente con respecto a cualquier producto o pieza del mismo que estén alterados o modificados sin el consentimiento previo explícito y por escrito de HoMedics.
Esta garantía le proporciona derechos legales específicos. Es posible que usted tenga derechos adicionales que pueden variar de un estado a otro. Debido a las regulaciones de ciertos estados, es posible que algunas de las limitaciones y exclusiones no se apliquen en su caso.
Por más información con respecto a nuestra línea de productos en los EE.UU.,
visítenos en: www.homedics.com
BPA-300-A.qxd 10/5/06 4:20 PM Page 1
de por vida
garntía limitada
lifetime
limited warranty
21
Important Notes Regarding Your
Blood Pressure Measurement . . . . . . . . . . . . .25
Recalibration Service . . . . . . . . . . . . . . . . . . . .26
Care, Maintenance & Cleaning . . . . . . . . . . . . .27
Potential for Radio/Television Interference . .29
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . .30
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .31
Lifetime Limited Warranty . . . . . . . . . . . . . . . .32
TABLE OF CONTENTS
INTRODUCTORY INFORMATION: Important Product Notices and Safety
Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
About Blood Pressure . . . . . . . . . . . . . . . . . . . .5
What is Blood Pressure? Why Measure Your Blood Pressure?
Blood Pressure Standard . . . . . . . . . . . . . . . . . .5
How This Blood Pressure Monitor Works . . . . .7
USAGE INFORMATION:
Name/Function of Each Part . . . . . . . . . . . . . . . .8
Display Explanations . . . . . . . . . . . . . . . . . . . . .9
Installing Batteries . . . . . . . . . . . . . . . . . . . . . .11
Using the AC Adapter . . . . . . . . . . . . . . . . . . . .12
Date & Time Set Procedure . . . . . . . . . . . . . . .13
Using The Arm Cuff . . . . . . . . . . . . . . . . . . . . .14
Measurement Procedure . . . . . . . . . . . . . . . . .18
Risk Category Indicator . . . . . . . . . . . . . . . . . .21
Irregular Heartbeat Detector . . . . . . . . . . . . . .22
Recalling Values from Memory . . . . . . . . . . . .23
Clearing Values from Memory . . . . . . . . . . . . .24
BPA-300-A.qxd 10/5/06 4:20 PM Page 1
43
IMPORTANT PRODUCT NOTICES AND SAFETY INSTRUCTIONS
When using your blood pressure monitor, basic pre­cautions should always be followed. Please read and follow all instructions and warnings before using this product. Save these instructions for future reference.
• Please note that this is a home healthcare product only and it is not intended to serve as a substitute for the advice of a physician or medical professional.
• Do not use this device for diagnosis or treatment of any health problem or disease. Measurement results are for reference only. Consult a healthcare profes­sional for interpretation of pressure measurements. Contact your physician if you have or suspect any medical problem.
• Proper cuff size is critical for accurate measurements. Follow the instructions in this manual and printed on the arm cuff to ensure the appropriate size of cuff is being used.
• This product is not suitable for people with arrythmias. This device may have difficulty determining the proper
blood pressure for individuals with diabetes, poor circulation of blood, kidney problems or for users who have suffered from a stroke.
• The pulse display is not suitable for checking the frequency of heart pacemakers.
• Electromagnetic interference: The device contains sensitive electronic components. Avoid strong electrical or electromagnetic fields in the direct vicinity of the device (e.g. mobile telephones, microwave ovens). These may lead to temporary impairment of measurement accuracy.
• Use blood pressure monitor only for its intended use.
• Do not wrap the cuff around body parts other than your arm.
• This unit is intended for use in measuring the blood pressure and pulse rate of adults. Do not use this device on infants or those who cannot express their own con­sent. This unit should not be operated by children.
• Do not plug or unplug the adapter power cord with wet hands.
Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope ausculatory method, within the limits prescribed by the American National Standard, Manual, electronic, or automated sphygmomanometers.
BPA-300-A.qxd 10/5/06 4:20 PM Page 3
65
Categories for Blood Pressure Levels in Adults
This monitor comes equipped with a Risk Category Indicator to visually indicate the assumed risk level of each reading based upon these standards. See page 21 for more information on this feature.
It is important that you consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk.
For reliable monitoring and reference of blood pressure, keeping long-term records is recommended.
ABOUT BLOOD PRESSURE
WWhhaa tt iiss BBlloooodd PPrr eessssuurree??
Blood pressure is the pressure exerted on the artery walls while blood flows through the arteries. The pressure measured when the heart contracts and sends blood out of the heart is systolic (highest) blood pressure. The pressure measured when the heart dilates with blood flowing back into the heart is called diastolic (lowest) blood pressure.
WWhhyy MMeeaassuu rree YY oouurr BBlloooodd PPrree ssssuurree??
Among today’s various health problems, those associated with high blood pressure are very common. High blood pressure dangerously correlates with cardiovascular diseases. Therefore, blood pressure monitoring is important for identifying those at risk.
BLOOD PRESSURE STANDARD
The U.S. Department of Health and Human Services and the National Institutes of Health have developed a blood pressure standard that identifies areas of low­and high-risk blood pressure. This standard, however, is a general guideline as an individual’s blood pressure varies among different people, age groups, etc.
For adults 18 and older who are not on medicine for high blood pressure, are not having a short-term serious illness, and do not have other conditions, such as diabetes and kidney disease.
To determine category of risk when systolic and diastolic readings fall into two areas, use the higher of the two numbers for classification.
There is an exception to the above definition of high blood pressure for people with diabetes and chronic kidney disease. A blood pressure of 130/80 mmHg or higher is considered high blood pressure for those individuals.
Systolic (mmHg) Diastolic (mmHg)
Stage 2 Hypertension >160 >100 Stage 1 Hypertension 140~159 90~99 Prehypertension 120~139 80~89 Normal <120 <80
__
BPA-300-A.qxd 10/5/06 4:20 PM Page 5
87
HOW THIS BLOOD PRESSURE MONITOR WORKS
This monitor uses advanced DK Technology™ to detect your blood pressure. With a microphone built into the arm cuff, DK Technology™ actually listens like your doctor when taking a reading. Exclusive DK Technology™ delivers accurate measurements by using both pressure and sound. With one press of a button, the device will automatically inflate to measure your systolic pressure. It will then begin deflating to measure your diastolic pressure. When the measurement is completed, it will display your systolic pressure, diastolic pressure, and pulse readings.
Based upon your measurement results, the monitor's Risk Category Indicator will alert you if your reading falls into the pre-hypertension, stage 1 hypertension, or stage 2 hypertension risk categories. See page 21 for more information on the Risk Category Indicator.
This monitor also features an irregular heartbeat (IHB) detector that will alert the user to the presence of an irregu­lar heartbeat. It is strongly recommended that you consult your physician if the IHB symbol appears often (five times or more in a row). See page 22 for more information on the IHB Detector.
NAME/FUNCTION OF EACH PART
Other Accessories Included :
LCD Display
Battery Cover
Memory Recall Button
START/STOP Button
User-Select Button
Cuff Tube and Connector
(Located
on bottom of unit)
Date/Time Set Buttons
(Located on back of unit)
1 12V DC Output AC Adapter and 4 “AA” size, 1.5V alkaline batteries Note: Please unload the batteries when operating with the AC adapter for an extended period of time.
Arm Cuff
BPA-300-A.qxd 10/5/06 4:20 PM Page 7
10
9
User 1: Appears when the monitor is operated by User 1. User 2: Appears when the monitor is operated by User 2.
Weak Battery Symbol: Appears when batteries should be
replaced.
Pulse Symbol: Shows the pulse rate per minute.
Irregular Heartbeat Detector: Indicates an irregular heartbeat
was detected. See page 22 for more information.
Memory Average: Displays average of last 3 readings
Risk Category Indicator: Compares readings against blood
pressure guidelines. See page 21 for more information.
DISPLAY EXPLANATIONS
Systolic Pressure
Diastolic Pressure
Date/Time Indicator
Display Symbols:
Pulse Rate
Measurement Error: Measure again. Wrap the cuff correctly and keep arm steady during measurement.
Air Circuit Abnormality: Check cuff connection. Measure again.
Pressure Exceeding 300 mmHg: Turn the unit off to clear,
then measure again.
Data Error: Remove and reload the batteries. Recalibration Alert: Recalibration recommended. See
page 26 for information.
If any of the following letters and numbers appear in the area that diastolic pressure should be displayed, an error has occurred with your reading. See Troubleshooting section of this manual for more information.
BPA-300-A.qxd 10/5/06 4:20 PM Page 9
12
11
As the supplied batteries are for test only, they may be discharged earlier than batteries you buy in stores. Replace the batteries in pairs. Remove batteries when unit is not in use for extended periods of time.
Note: Batteries are hazardous waste. Do not dispose
of them together with the household garbage.
USING THE AC ADAPTER
Note: • Please unload the batteries when operating
with the AC adapter for an extended period of time. Leaving the batteries in the compart­ment for a long time may cause leakage, which may lead to damage of the unit.
• No batteries are needed when operating with the AC adapter.
1. Connect the AC adapter with the AC adapter jack in the back of the unit as shown below.
2. Please use only the AC adapter included with this monitor.
AC Adapter
Input: 120V 60Hz 15W Output: 12V DC 600mA
Connect AC adapter here
INSTALLING BATTERIES
Note: It is recommended that you use batteries only
for travelling or when it is not possible to use the AC adapter.
1. Extend the tray so that the battery cover is fully exposed.
2. Press down on latch and lift the battery cover towards you to open the battery compartment.
3. Install or replace 4 “AA” sized batteries in the battery compartment according to the indications inside the compartment.
4. Replace the battery cover by clicking in the bottom hooks first, then push in the top end of the battery door.
Replace the batteries if:
1. The weak battery symbol appears on the display.
2. Nothing appears on the display when the power is switched on.
Battery Cover
Slide-Out Tray
BPA-300-A.qxd 10/5/06 4:20 PM Page 11
DATE & TIME SET PROCEDURE
1. To adjust the date/time, press the Set button ,
located on the back of the monitor.
2. The display will show a blinking number showing the hour. Change the hour by pressing the button. Each press will increase the number by one in a cycling manner. Press the Set button again to confirm the entry, and the screen will show a blink­ing number representing the minutes.
3. Change the time and date as described in Step 2 above, using the button to change the num­bers and the Set button to confirm the entries.
4. A “0” will reappear as the blood pressure monitor is ready for measurement again.
13
Press the button
blinking hour
increasing hour
confirm the entry
repeat process to set time and date
14
USING THE ARM CUFF
Very Important: Proper cuff size is critical to accurate measurement.
This monitor comes with two sizes of arm cuffs: Standard Size Fits 9.5"–14.2" (24 cm – 36 cm) Large Size Fits 13.4"–18.1" (34 cm – 46 cm)
The appropriate cuff is suitable for your use if the colored arrow falls within the solid color line as shown below. If the Arrow falls outside of the Solid Color Line, you
need a cuff with another circumference. For circumferences less than 9.5", contact HoMedics Consumer Relations.
A
R
R
O
W
M
U
S
T
F
A
L
L
W
I
T
H
I
N
Y
E
L
L
O
W
B
A
N
D
Solid Colored Line
Colored Arrow
BPA-300-A.qxd 10/5/06 4:20 PM Page 13
P
o
s
i
ti
o
n
c
u
f
f
ed
g
e 0
.
6
˝
1
.0
˝
(1
.5
2
.
5
c
m
)
a
b
o
v
e
el
b
o
w
.
Standard
ARROW MUST FALL
WITHIN YELLOW BAND
Ce
nt
e
r
t
ube
m
id
d
l
e of
Center tube over middle of arm
Size Cuff Fits:
9
.5
14
.2
In
c
h
e
s
2
4
3
6
C
e
n
t
im
e
te
ec
u
re
l
y
.
Al
s
t
o
f
i
t
b
a
r
m.
MODEL# PP-BPCUFF5
rs
l
o
w
ro
o
m
f
o
r
etwe
e
n
t
h
e
c
u
f
f
Fit
cu
f
f
s
o
v
er
tw
o
f
ing
er
a
r
m
.
an
d
y
o
u
r
3. Open the arm cuff so that your arm may be placed through it.
4. Remove tight fitting clothing from around your upper left arm.
5. Position cuff edge 0.8-1.2 inches (2-3cm) above elbow.
6. Center tube over middle of arm.
7. Pull the end of the cuff so that it tightens evenly around your arm. Press the hook and loop material together to secure. Allow room for 2 fingers to fit between the cuff and your arm.
8. Lay your arm on a table (palm upward) so the cuff is at the same height as your heart. Make sure the tube is not kinked.
16
15
1. If the cuff is not assembled, pass the end of the cuff furthest away from the tubing through the metal D-ring in order to form a loop. The smooth side without the felt material should be on the inside of the cuff loop.
2. Plug the cuff tube into the left side of the unit.
P o
s it io n
cuf
f
edg
e 0 .6
˝
1 .0
˝
(
1. 5
2 . 5 c m)
ab
o ve el
b ow
C en
t e r
tu b
e ov
e r
m id d
le of a
r m
.
Insert plug here
A
R
R
O
W
M
U
S
T
F
A
L
L
W
I
T
H
I
N
Y
E
L
L
O
W
B
A
N
D
D-ring
End of cuff
Felt Material on the outside of cuff
BPA-300-A.qxd 10/5/06 4:20 PM Page 15
1817
MEASUREMENT PROCEDURE
Important Notes:
• Blood pressure changes with every heartbeat and is in constant fluctuation throughout the day.
• Blood pressure measurement can be affected by the position of the user, his or her physiologic condition and other factors. For greatest accuracy, wait 1 hour after exercising, bathing, eating, drinking beverages with alcohol or caffeine, or smoking to measure blood pressure.
• Before measurement, it is suggested that you sit quietly for 15 minutes as measurements taken during a relaxed state will have greater accuracy. You should not be physically tired or exhausted while taking a measurement.
• During the measurement, do not talk or move your arm or hand muscles.
• See page 25 for additional notes regarding your blood pressure measurement.
Note:
If it is not possible to fit the cuff to your left arm, it can also be placed on your right arm. However, all measurements should be made using the same arm. To use on the right arm, you must position the artery symbol “ ” over the main artery. Locate the main artery by pressing with two fingers approximately 1" (2 cm) above the bend of your elbow on the inside of your right arm. Identify where the pulse can be felt the strongest. This is your main artery.
Main Artery
BPA-300-A.qxd 10/5/06 4:20 PM Page 17
2019
3. After all symbols disappear, the display will
show a blinking “0”. The monitor is “Ready to Measure” and will automatically inflate the cuff to start measurement.
4. Once your systolic pressure is determined, the monitor
will begin deflating to measure your diastolic pressure.
Note: This monitor will re-inflate automatically if the
system detects that your body requires more pressure for measurement.
5. When the measurement is completed, the cuff will
deflate entirely. Systolic pressure, diastolic pressure and pulse will be shown simultaneously on the LCD screen. The measurement is then automatically
stored into memory.
1. Press the User Select Button to choose User 1
or User 2.
After the user number is selected, press the START/STOP button to confirm the chosen user.
2. With the cuff wrapped around your arm, press the
START/STOP button. Do not inflate the cuff unless it is wrapped around your arm. All digits will light up to check the display functions. The checking procedure will be completed after about 2 seconds.
START
STOP
/
OR
BPA-300-A.qxd 10/5/06 4:20 PM Page 19
Loading...
+ 23 hidden pages