HomeDefender HD-G005 Installation And User Manual

SECURITY KIT GSM
PROTECT
YOUR HOME
INSTALLATION AND USER
MANUAL
HD-G005
GSM - SMS - RFID - TOUCH
Printed in Hong Kong PA: HD-G5/EN-Aug.2012-V1.1
Content of Package:
Control panel complete with internal siren, GSM dialer, RFID reader, backup batteries and 110~240VAC/12VDC power adapter.
PIR motion sensor complete with battery.
Magnetic door and window contact complete with battery.
4 button remote control complete with battery.
HomeDefender intruder’s alarm is a secure and efficient wireless alarm system protecting persons and property promptly indicating any attempt of intrusions by means of audible and visual alarms and with telephone calls and SMS messages. The system consists of a programmable control panel to monitor and supervise the wireless detectors, command and control devices, motion sensor (IR technology) for internal protection of the premises and perimetric sensor to protect doors and windows. By adding specific devices the equipment can also operate safety functions such as the Remote Help for the elderly and protect home against gas or water leaks. All HomeDefender equipments, like this intruder alarm are based on RF technology, meaning that all the devices are connected wirelessly making installation easy and quick with high security standards ideal for DIY (Do-It-Yourself) applications. To guide you through instal­lation, to help you solve your problem or simply suggest how to make your home or office a safer place, call our free tech support. We’ll be happy to help you!
TECHNICAL SUPPORT
+39.02.4507 2208
Mon. - Fri. 9:00 - 13:00
support@homedefender.it
RFID tags.
www.homedefender.it
Characteristics
ARM + Auror CPU
Support up to 10 remote controls and 50 RFID Tags/Cards
Support up to 50 wireless detectors
Support up to 50 zones (9 personalised zone)
Support 2 wired sensors and 1 wired siren
Support 1 electronic door lock
Up to 1,000,000 RF combinations
GSM cellular communication
Store up to 5 numbers for emergency SMS
Store up to 5 numbers for emergency calls
Store 1 number for SMS notification of RFID notifications
Possibility to make phone calls directly from the control panel
Records 1 voice memo
Delay entry and exit
Sensor low battery warning
Arm and Disarm by SMS or phone call
Settings inquiry by SMS
Remote monitoring by phone
Two 700mA Lithium batteries guarantee up to 15 hours stand-by
SMS alert for power failure, power recovery and low battery
Tamper protection
Alarm System Positioning plan
In order to ensure an efficient and secure protection of the installation place (home or office) all weak points need to be carefully identified.
Every sensor identifies an individual zone and is recognised sequen­tially during the programming.
The names of the first 9 sensors can be personalised. The remaining are numbered from 10 to 50.
Example:
8
1
2
7
3
4
9
5
C
CONTROL PANEL
REMOTE CONTROL
EXTERNAL SIREN
C
Zone 1 Sensor: “Entry Door ”
1
Zone 2 Sensor: “Living Room PIR”
2
Zone 3 Sensor: “Liv. Room. Window”
3
Zone 4 Sensor: “Terrace Window”
4
6
Zone 5 Sensor: “Terrace Door”
5
Zone 6 Sensor: “Bed Room Window”
6
Zone 7 Sensor: “Bed Room PIR”
7
Zone 8 Sensor: “Kitchen Gas”
8
Zone 9 Sensor: “Bath Room Water”
9
GSM - SMS - RFID - TOUCH
Wireless Security Alarm System
HD-G005 is a domestic security system with GSM dialer that provides
the following protection functions:
• INTRUDER ALARM using motion or perimetric sensors
• REMOTE HELP using remote control’s panic button
• DOMESTIC SECURITY using Gas, Smoke or Water detectors
Operations
INTRUDER ALARM function can be programmed in 3 different ways:
1) Normal Mode (total protection): all sensors are armed.
2) Home Mode (partial protection): the perimetric sensors are armed while the motion sensors, previously programmed in Home Mode, are disarmed.
3) Delay Mode (total cover): the detectors programmed in this way allow a time delay to enable the protected rooms to be entered and exited without setting off the alarm.
REMOTE SUPPORT function can be armed in emergency situations by means of the SOS panic button on the remote controls. The siren will sound, SMS and phone calls will be made as programmed.
DOMESTIC SECURITY function can be armed by configuring the smoke, water and gas detectors and arming perimetric sensors installed in zones not subject to access (H24 Mode: it always arms regardless of the system status).
REMOTE MONITORING is activated on every intrusion or by sending an SMS to the control panel that will call back immediately thus opening a hands free communication channel with the home or office where installed. Particularly useful for communicating to people with restricted move­ment and to help them as needed.
• REMOTE MONITORING using telephone
The system is configured and managed from the control panel by sending SMS and with telephone calls. Any change of status is notified to the numbers in memory by SMS.
1 2
The system can also be disarmed using RFID devices like “Cards” or “Tags”. The system support up to 50 RFID devices of which 4 can be personal­ized with user names. Whenever any RFID device is used an SMS notification message will be sent to the previously registered number.
Control Panel: Front
Control Panel: Back
GSM Signal Indicator
Search GSM signal: flashes every second
Normal GSM signal: flashes every 2 seconds
Status Indicator
Touch Pa ne l
Arm
Disarm
Call
Arm (Home Mode)
RFID Reader /
Play Voice Memo
Record Voice Memo /
Connect Button
Touch panel is activated by finger contact, it is not necessary to press hard. The RFID reader needs to be within one centimeter to read the RFID devices without necessarily touching the panel.
SIM card slot
2 Inputs for wired sensors
Output for Electronic lock
Output for wired siren 500 mA
Power plug
On / Off Switch
Insert SIM card in the slot before switching the system on with the ON/OFF switch.
A wired siren can be connected to the system and up to 2 wired sensors can be connected to Z1 (H24 Mode) and Z2 (Normal Mode) inputs. The system automatically recognises the sensor’s normal status (N/C
Tamper Switch
Speaker
Microphone
Back up batteries
– Normally Closed or N/O – Normally Open).
3 4
Control Panel: functions
Arm
Touch to Arm the system.
Arm (Home Mode)
Touch to Arm the system in Home Mode and freely move in the domestic environment. Peripheral Sensors will be armed, while the internal ones will not communicate the presence of persons to the control panel.
Disarm
Digit the 4~6 digit password wait for the beep and touch to Disarm the system (default password is: 1234). Three beeps indicate wrong password. Type the password again.
Record / Play Voice Memo
The system enables a 10 seconds voice message to be recorded for family members and/or colleagues. The message can also be recorded remotely by sending an SMS. Using the control panel proceed as follows:
Touch to the 10 second voice message. The button will flash to confirm.
Touch to play back the message. The flashing light will go off once the voice message has been played.
Replay by touching again.
Disarm with RFID tags.
Induce RFID tag to the RFID area to disarm the system.
5 6
RFID tags
Speed Dial
RFID is a technology that enables objects to be identified by means of radio frequencies (Radio Frequency IDentification). It consists of a read/write system and devices that contain the information (TAGS/ Cards or labels). Once the TAGS are programmed, passing them close to the reader will disarms the system and unlock an electronic door lock (if connected). Up to 4 RFID tags can be renamed and one mobile phone number recorded to be notified by SMS when a RFID user disarms the system (SMS “7” Command - page 17).
A specific telephone number can be recorded for Speed Dials (SMS “8” Command - page 18). Touch to Speed Dial. The LED lights on. To end the phone call touch again. The LED lights off at the end of the call.
Phone Calls
Enter the telephone number to be called directly on the keyboard
Nancy
Nancy came home
Note:
Up to 50 RFID tags or cards can registered. 4 RFID tags or cards can be assigned with the name of the holder in order to be informed by SMS of whom has disarmed the system. Only one telephone number can be defined to receive the notification (SMS “10” Command - page 21).
7 8
Mom
and touch to start the call The LED lights on. To end the phone call touch again. The LED lights off at the end of the call.
Electronic Door Lock
If the premises entrance door is provided with electronic lock, it can be connected to the control panel to be operated by the RFID device. Disarming the system will thus open the electronic lock connected to it.
SMS Operation
The advanced functions of the system must be programmed by means of SMS communications. Make sure you have credit left and that the system has been unblocked with the PIN code before inserting the SIM card into the slot located on the back of the control panel. Send an SMS to the number of the card with the text “?”. IThe guide menu to the operations is received in reply. The menu is available at 3 levels to ease the interrogation.
Send:
The response of the system contains the first level guide menu:
Send:
The response of the system contains the second level guide menu:
Send:
The response of the system contains the third level guide menu:
By interrogating the control panel by SMS the complete configura­tion of the alarm system can be managed as in the following examples.
9 10
Loading...
+ 16 hidden pages