The RC-2000 is a precision digital thermostat designed for 24 VAC heating and cooling systems. The
RC-2000 will support the following systems:
Single Stage Heat/Cool Conventional
Two Stage Conventional (2 Stage Heat / 2 Stage Cool)
Heat Pump and Geothermal Heat Pump (2 Stage Heat / 1 Stage Cool)
Two Speed Heat Pump and Geothermal Two Speed Heat Pump (3 Stage Heat / 2 Stage Cool)
Dual Fuel Heat Pump and Geothermal Dual Fuel Heat Pump
Humidifier and Dehumidifier Control
The RC-2000 has the capability of being controlled both locally and by remote control. It offers
programmability, stand-alone operation, and robust, optically isolated communications with automation
systems, utility control systems, and personal computers.
Electrical rating: 24 V; 2 A; 50/60 Hz
Maximum current: 2 A on any circuit, 3 A total
The following requirements must be observed for installation in Europe: CE
1. This equipment must be installed in accordance with National wiring rules for the country in which it is
installed.
2. All product labels, instructions and markings relating to safety must be translated to a language, which is
acceptable in the country in which this equipment is to be installed.
INSTALLATION
Before installing this thermostat:
1. Read all of the Installation Instructions carefully.
2. Read the Owner's Manual carefully.
3. Ensure that this product is suitable for your application.
4. Ensure that wiring complies with all codes and ordinances.
5. Disconnect power to the control transformer to prevent electrical shock and damage to equipment.
6. Select an appropriate location to ensure an accurate temperature reading.
Document Number 65I00-2 / Rev B / February, 2010
Copyright 2008-2010 Home Automation, Inc.
All Rights Reserved
1
1
Location
When replacing an existing thermostat, install the RC-2000 in the same location. If the existing location doesn't
meet the following criteria, choose a new location to mount the RC-2000. When choosing a location for the
thermostat:
1. Ensure that the thermostat is mounted 5 feet above the floor and is at least 2 feet from an outdoor wall.
2. Ensure that the thermostat is located in an area where there is adequate air circulation.
3. Do not mount in the path of direct sunlight or of radiant heat generated by appliances.
4. Do not mount behind an outdoor wall, near a fireplace, or in the path of any air ducts.
Removing an existing thermostat
1. Disconnect the power to the control transformer.
2. Remove the cover to the existing thermostat.
3. Disconnect the wires going to each terminal on the thermostat. Label each wire with the letter or number
at the terminal.
4. Remove the existing plate or base from the wall.
MOUNTING
When mounting the RC-2000, grasp the thermostat by the sides, avoiding the keys, and unsnap the base from
the face. Holding the base to the wall so that the word "UP" is upright and facing you:
1. Mark the two mounting holes on the wall using a pencil.
2. Drill a hole using a 3/16" bit at each mounting hole marking.
3. Install the two wall anchors supplied.
4. Slide the system wires through the opening in the base.
5. Mount the base to the wall using the two #6 x 1/2" self-tapping screws supplied - SeeFigure 1.
Figure 1
2
2
Connect each wire to the terminal strip(s) on the thermostat base per the wiring diagram for your system
application - See Figures 4 - 10. Form the thermostat wiring so that the cable lies flat between the terminal
strip(s) and the center of the base - See Figure 2.
If a remote system or temperature sensor is being used with the thermostat, connect the remote system or
temperature sensor wiring per the diagram for the application - See Figures 12 - 14.
Upon completion of wiring the thermostat, push all excess wiring into the hole in the wall. Plug the hole with
the supplied insulating foam to ensure an accurate temperature reading by the thermostat.
Align the tabs of the thermostat face with the slots of the thermostat base. Gently push the thermostat face into
the thermostat base locking it into place - See Figure 2.
Wall
Slot
Base
Temperature
Sensor
Tab
Figure 2 Figure 3
Note:
Be sure that the thermostat temperature sensor is standing up, and that it has not been damaged during
installation - See Figure 3.
3
3
TYPICAL WIRING DIAGRAMS
CAUTION:
Do not short gas valve, fan, heat relay, or cool relay...even momentarily.
Do not attempt to hook up to live circuits. An accidental connection to a component on the thermostat circuit
board could cause damage to the thermostat.
Be sure to disconnect the power to the control transformer before removing
or installing thermostat.
UP
JUMPER
3
2
1
24VAC Common
24VAC "HOT"
THERMOSTAT
For HVAC systems with a single transformer, the metal jumper between Terminal 1 (RC) and
Terminal 2 (RH) on the left terminal strip must remain in place.
(C)
(RC)
24VAC
CONTROL
TRANSMFOMER
Figure 4 – Thermostat power-up for test or configuration purposes
Important Notes:
1. For HVAC systems with a single transformer for heating and cooling, the metal jumper between
Terminal 1 (RC) and Terminal 2 (RH) on the left terminal strip must remain in place – See Figure 4.
2. From the factory, the RC-2000 is configured to control a single stage conventional HVAC system.
If the HVAC system is a heat pump, dual fuel heat pump, or if the thermostat is connected to a zone
control system that requires a sub-base, before operating the thermostat, the “System Type” settings
under “System Options” must be configured – SeeInstallation Settings.
If the HVAC system is a two stage conventional or two speed heat pump, before operating the
thermostat (making a call for heat or cool), the “Cool Stages” and “Heat Stages” settings under
“Stage Settings” must be configured – See Installation Settings.
4
4
3. When configured as a conventional thermostat, by default this thermostat does not turn the fan on with a
call for heat. If the furnace requires the thermostat to turn the fan on with a call for heat, configure the
“System Mode” to “Fan On With Heat” under “System Options”.
4. A conventional thermostat can be configured for automatic changeover heat/cool, manual changeover
heat/cool, heat only, or cool only thermostat.
5. Refer to the “Configuration” steps under the wiring diagram for the respective HVAC system type.
6. If the thermostat or HVAC system does not perform as stated in the “Power Up” steps under the wiring
diagram for the respective HVAC system, recheck all wiring - See Troubleshooting Tips.
7. For HVAC systems with separate heating and cooling transformers, the metal jumper between
Terminal 1 (RC) and Terminal 2 (RH) on the left terminal strip must be removed – See Figure 5.
UP
REMOVE
JUMPER
3
2
1
24VAC Common
24VAC Heat "HOT"
24VAC Cool "HOT"
THERMOSTAT
For HVAC systems with separate heating and cooling transformers, the metal jumper between
Terminal 1 (RC) and Terminal 2 (RH) on the left terminal strip must be removed.
Figure 5 – Connections for heat and cool transformers - applies to all systems
(C)
(RH)
(RC)
24VAC
HEAT
TRANSMFOMER
24VAC
COOL
TRANSMFOMER
5
5
Single Stage Conventional
HVAC SYSTEM
Dehumidifier
Humidifier
Fan Relay
Cool Relay
Heat Relay
24VAC
CONTROL
TRANSMFOMER
12
11
8
7
6
3
1
Dehumidier
Humidifier
Fan
Cool
Heat
24VAC Common*
24VAC "HOT"
(D)
(H)
(G)
(Y1)
(W1)
(C)
(RC)
THERMOSTAT
UP
* Common wire is required in “heat only” or “cool only” applications. Also use a common if heat, cool,
or fan relay cannot supply 15mA to power thermostat, without activating.
Figure 6 – Connections for single stage heat/cool thermostat
CONFIGURATION
From the factory, the RC-2000 is configured as a single stage conventional heat/cool thermostat.
In the default configuration, this thermostat does not turn the fan on with a call for heat. If the furnace does
not turn the fan on with a call for heat, the thermostat must be configured to do so under “System Options”.
POWER UP
1. Double check wiring, be sure that there are no stray wires or wire strands at the connections.
2. Connect power to the transformer and system. The display will show the current thermostat settings.
3. Press [FAN] and select “On”. The fan should come on.
4. Press [FAN] and select “Auto”. The fan should go off.
5. Set the Mode to "Heat". Raise the desired heat setting above the current temperature. Ensure that the
heating unit comes on. Set the mode to "Off". Ensure that the heating unit goes off.
6. Set the Mode to "Cool". Lower the desired cool setting below the current temperature. Ensure that the
cooling unit comes on. Set the mode to "Off". Ensure that the cooling unit goes off.
The RC-2000 thermostat is designed to work with most single state conventional 4-wire HVAC systems
(without a transformer common). However, if the RC-2000 “resets” when calling for heat or cool, or if the
heat, cool, or fan relay cannot supply 15mA to power thermostat without the relay activating, the transformer
common wire or the HAI Thermostat Power Supply Module (Part Number: 30A00-1) is required.
6
6
Single Stage Conventional for Zone Control Systems
ZONE CONTROLLER
Dehumidifier
Humidifier
System Cool Mode
Fan Relay
Zone Cool
Zone Heat
System Heat Mode
24VAC
CONTROL
TRANSMFOMER
12
11
10
8
7
6
4
3
1
Dehumidier
Humidifier
Cool Mode
Fan
Cool
Heat
Heat Mode
24VAC Common
24VAC "HOT"
(D)
(H)
(Y2)
(G)
(Y1)
(W1)
(W2)
(C)
(RC)
THERMOSTAT
UP
Figure 7 – Connections for single stage thermostat for zone control systems
CONFIGURATION
The “System Type” for this thermostat must be set to “Zone Control” under “System Options”.
The two additional outputs (W2 and Y2) are use with zoned heating and cooling systems. The W2 and Y2
terminals control the mode of operation (heating or cooling) of the zone control panel. The zone control panel
will recognize calls for heat (W) from the individual zones when the W2 terminal is energized, and calls for
cool (Y) when the Y1 terminal is energized. Neither W2 nor Y2 is energized when the mode is set to "OFF".
Therefore, the RC-2000 can act as a Master to set the operating mode of the entire system.
POWER UP
1. Double check wiring, be sure that there are no stray wires or wire strands at the connections.
2. Connect power to the transformer and system. The display will show the current thermostat settings.
3. Press [FAN] and select “On”. The fan should come on.
4. Press [FAN] and select “Auto”. The fan should go off.
5. Set the Mode to "Heat". Raise the desired heat setting above the current temperature. Ensure that the
heating unit comes on. Set the mode to "Off". Ensure that the heating unit goes off.
6. Set the Mode to "Cool". Lower the desired cool setting below the current temperature. Ensure that the
cooling unit comes on. Set the mode to "Off". Ensure that the cooling unit goes off.
7
7
Two Stage Conventional (2 Stage Heat / 2 Stage Cool)
12
11
10
8
7
6
4
3
1
Dehumidier
Humidifier
Cool 2
Fan
Cool 1
Heat 1
Heat 2
24VAC Common*
24VAC "HOT"
(D)
(H)
(Y2)
(G)
(Y1)
(W1)
(W2)
(C)
(RC)
THERMOSTAT
UP
HVAC SYSTEM
Dehumidifier
Humidifier
Cool 2 Relay
Fan Relay
Cool 1 Relay
Heat 1 Relay
Heat 2 Relay
24VAC
CONTROL
TRANSMFOMER
Figure 8 – Connections for two stage conventional thermostat
CONFIGURATION
The “System Type” for this thermostat must be set to “Conventional” under “System Options”.
In the default configuration, this thermostat does not turn the fan on with a call for heat. If the furnace does
not turn the fan on with a call for heat, the thermostat must be configured to do so under “System Options”.
The “Cool Stages” and “Heat Stages” settings must be configured under “Stage Settings”.
POWER UP
1. Double check wiring, be sure that there are no stray wires or wire strands at the connections.
2. Connect power to the transformer and system. The display will show the current thermostat settings.
3. Press [FAN] and select “On”. The fan should come on.
4. Press [FAN] and select “Auto”. The fan should go off.
5. Press [HOLD] and select “On” to override Energy Efficient Control.
6. Set the Mode to "Heat". Raise the desired heat setting 1 degree above the current temperature. Ensure
that Stage 1 heat comes on. After a few minutes, raise the desired heat setting 3 degrees above the current
temperature. Stage 2 heat should come on. Set the mode to "Off". Ensure that the heating unit goes off.
7. Set the Mode to "Cool". Lower the desired cool setting 1 degree below the current temperature. Ensure
that Stage 1 cool comes on. After a few minutes, lower the desired cool setting 3 degrees below the
current temperature. Stage 2 cool should come on. Set the mode to "Off". Ensure that the cooling unit
goes off.
8. Press [HOLD] and select “Off” to enable Energy Efficient Control.
8
8