This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
User’s Guide
o For use with HAI Omni-Bus Output devices
o Requires an HAI Omni-Bus RF Transceiver or HAI Omni-Bus
Translator Interface on the Omni-Bus network
o Frequency: 433.92MHz
o Range: Up to 30m (98 feet)
INSTALLATION
Before installing the Wall Mount Remote Control, PROGRAM the
Wall Mount Remote Control into the target receiving device.
Programming is still possible after installation, but might require
the co-operation of two people if the receiving device is situated
far away from the Wall Mount Remote Control.
The Wall Mount Remote Control does NOT require ANY wiring. It
is a self-contained, battery-operated unit.
FUNCTIONS
To switch a device ON or OFF
Press and release the button on the Wall
Mount Remote Control.
To DIM a light (when used with an Omni-Bus Dimmer unit)
Press and hold the button on the Wall Mount
Remote Control.
To RESTORE to a previous light intensity when the light is
switched OFF (Light Dimmer only)
Simply press and hold the button on the Wall Mount Remote
Control. Release the button as soon as the light turns on.
OMNIBUS PROGRAMMING
See the HAI OMNIBUS Software User Guide for more information
on how to program the remote control into an Omni-Bus output
device using the OMNIBUS Installation Software.
MANUAL PROG RAMM ING
1. Place the receiving device into the programming mode. This
is normally done by pressing and holding the button on the
receiving device until its LED starts flashing continuously.
(See receiving device user guide for more information).
2.
3. Exit the programming mode on the receiving device.
(See receiving device user guide for more information).
Press and hold the button on the Wall Mount
Remote Control for exactly 10 seconds before
releasing it. Check for a confirmation signal
from the receiving device.
device user manual for more information).
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
The Wall Mount Remote Control has two modes of operation:
TOGGLE MODE (factory default)
In this mode, the LED indicator on the Wall Mount Remote Control
flashes 3 times when the button is pressed and released.
Every time the button on the Wall Mount Remote Control is pressed
and released, it instructs the receiving device to change its state. So
if the receiving device had been ON, it would now switch OFF or
vice versa.
ON/OFF MODE
In this mode, the LED indicator either flashes once or twice when
the button is pressed and released.
One flash indicates that the receiving device will be instructed to
switch ON, regardless of its current state.
Two flashes indicate that the receiving device will be instructed to
switch OFF, regardless of its current state.
CHANGING THE OPERATIONAL MODE
Press and release the button three times rapidly while the LED is
ON.
If the Wall Mount Remote Control was in TOGGLE mode, it will
change to the ON/OFF mode.
If the Wall Mount Remote Control was in the ON/OFF mode, it will
change to TOGGLE mode.
DELETING A REMOTE CONTROL
A Wall Mount Remote Control channel programmed into an
Omni-Bus receiving device may be deleted from that device by
following the procedure below:
1. Place the receiving device into the programming mode. This is
normally done by pressing and holding the button on the
receiving device until the receiving device LED starts flashing
continuously. (See receiving device user guide for more
information).
2.
3. Exit the programming mode on the receiving device. (See
receiving device user guide for more information).
Press and hold the channel button on the Wall
Mount Remote Control until the indicator LED
turns on without flashing. (this operation takes
approximately 20 seconds). Release the button.
Press and hold the button on the Wall Mount
Remote Control for exactly 14 seconds before
releasing it. Check for a confirmation signal
from the receiving device. (See receiving device
user guide for more information).
REMOTE CONTROL BATTERY REPLACEMENT
When the indicator LED does not function when the button is
pressed, the battery needs to be replaced.
The Wall Mount Remote Control uses one type 23A 12V battery.
HAI Omni-Bus 2-Channel Wall Remote
Model 113A00-4
SPECIFICATIONS
OPERATIONAL MODES
seconds before releasing it. Check for a
FCC ID: HHC-113A00-4
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
User’s Guide
o 2 Channels
o For use with HAI Omni-Bus Output devices
o Requires an HAI Omni-Bus RF Transceiver or HAI Omni-Bus
Translator Interface on the Omni-Bus network
o Frequency: 433.92MHz
o Range: Up to 30m (98 feet)
INSTALLATION
Before installing the Wall Mount Remote Control, PROGRAM the
Wall Mount Remote Control into the target receiving device.
Programming is still possible after installation, but might require
the co-operation of two people if the receiving device is situated
far away from the Wall Mount Remote Control.
The Wall Mount Remote Control does NOT require ANY wiring. It
is a self-contained, battery-operated unit.
FUNCTIONS
To switch a device ON or OFF
To DIM a light (when used with an Omni-Bus Dimmer unit)
To RESTORE to a previous light intensity when the light is
switched OFF (Light Dimmer only)
Simply press and hold the button on the Wall Mount Remote
Control. Release the button as soon as the light turns on.
OMNIBUS PROGRAMMING
See the HAI OMNIBUS Software User Guide for more information
on how to program the remote control into an Omni-Bus output
device using the OMNIBUS Installation Software.
MANUAL PROG RAMM ING
1. Place the receiving device into the programming mode. This
is normally done by pressing and holding the button on the
receiving device until its LED starts flashing continuously.
(See receiving device user guide for more information).
2.
3. Exit the programming mode on the receiving device.
(See receiving device user guide for more information).
Press and release the appropriate button on
the Wall Mount Remote Control.
Press and hold the appropriate button on the
Wall Mount Remote Control.
Press and hold the appropriate button on the
Wall Mount Remote Control for exactly 10
seconds before releasing it. Check for a
confirmation signal from the receiving device.
(See receiving device user manual for more
information).
The Wall Mount Remote Control has two modes of operation:
TOGGLE MODE (factory default)
In this mode, the LED indicator on the Wall Mount Remote Control
flashes 3 times when the button is pressed and released.
Every time a button on the Wall Mount Remote Control is pressed
and released, it instructs the receiving device to change its state. So
if the receiving device had been ON, it would now switch OFF or
vice versa.
ON/OFF MODE
In this mode, the LED indicator either flashes once or twice when
the button is pressed and released.
One flash indicates that the receiving device will be instructed to
switch ON, regardless of its current state.
Two flashes indicate that the receiving device will be instructed to
switch OFF, regardless of its current state.
CHANGING THE OPERATIONAL MODE
Each channel (button) of the Wall Mount Remote Control may be
configured independently for either TOGGLE or ON/OFF mode.
Press and release the button three times rapidly while the LED is
ON.
If the Wall Mount Remote Control channel was in TOGGLE mode, it
will change to the ON/OFF mode.
If the Wall Mount Remote Control channel was in the ON/OFF
mode, it will change to TOGGLE mode.
DELETING A REMOTE CONTROL CHANNEL
A Wall Mount Remote Control channel programmed into an
Omni-Bus receiving device may be deleted from that device by
following the procedure below:
1. Place the receiving device into the programming mode. This is
normally done by pressing and holding the button on the
receiving device until the receiving device LED starts flashing
continuously. (See receiving device user guide for more
information).
2.
3. Exit the programming mode on the receiving device. (See
receiving device user guide for more information).
Press and hold the appropriate channel button
on the Wall Mount Remote Control until the
indicator LED turns on without flashing. (this
operation takes approximately 20 seconds).
Release the button.
Press and hold the appropriate button on the
Wall Mount Remote Control for exactly 14
confirmation signal from the receiving device.
(See receiving device user guide for more
information).
REMOTE CONTROL BATTERY REPLACEMENT
When the indicator LED does not function when the button is
pressed, the battery needs to be replaced.
The Wall Mount Remote Control uses one type 23A 12V battery.
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
HAI Omni-Bus 3-Channel Wall Remote
Model 113A00-7
SPECIFICATIONS
OPERATIONAL MODES
seconds before releasing it. Check for a
FCC ID: HHC-113A00-4
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
User’s Guide
o 3 Channels
o For use with HAI Omni-Bus Output devices
o Requires an HAI Omni-Bus RF Transceiver or HAI Omni-Bus
Translator Interface on the Omni-Bus network
o Frequency: 433.92MHz
o Range: Up to 30m (98 Feet)
INSTALLATION
Before installing the Wall Mount Remote Control, PROGRAM the
Wall Mount Remote Control into the target receiving device.
Programming is still possible after installation, but might require
the co-operation of two people if the receiving device is situated
far away from the Wall Mount Remote Control.
The Wall Mount Remote Control does NOT require ANY wiring. It
is a self-contained, battery-operated unit.
FUNCTIONS
To switch a device ON or OFF
To DIM a light (when used with an Omni-Bus Dimmer unit)
To RESTORE to a previous light intensity when the light is
switched OFF (Light Dimmer only)
Simply press and hold the button on the Wall Mount Remote
Control. Release the button as soon as the light turns on.
OMNIBUS PROGRAMMING
See the HAI OMNIBUS Software User Guide for more information
on how to program the remote control into an Omni-Bus output
device using the OMNIBUS Installation Software.
MANUAL PROG RAMM ING
1. Place the receiving device into the programming mode. This
is normally done by pressing and holding the button on the
receiving device until its LED starts flashing continuously.
(See receiving device user guide for more information).
2.
3. Exit the programming mode on the receiving device.
(See receiving device user guide for more information).
Press and release the appropriate button on
the Wall Mount Remote Control.
Press and hold the appropriate button on the
Wall Mount Remote Control.
Press and hold the appropriate button on the
Wall Mount Remote Control for exactly 10
seconds before releasing it. Check for a
confirmation signal from the receiving device.
(See receiving device user manual for more
information).
The Wall Mount Remote Control has two modes of operation:
TOGGLE MODE (factory default)
In this mode, the LED indicator on the Wall Mount Remote Control
flashes 3 times when the button is pressed and released.
Every time a button on the Wall Mount Remote Control is pressed
and released, it instructs the receiving device to change its state. So
if the receiving device had been ON, it would now switch OFF or
vice versa.
ON/OFF MODE
In this mode, the LED indicator either flashes once or twice when
the button is pressed and released.
One flash indicates that the receiving device will be instructed to
switch ON, regardless of its current state.
Two flashes indicate that the receiving device will be instructed to
switch OFF, regardless of its current state.
CHANGING THE OPERATIONAL MODE
Each channel (button) of the Wall Mount Remote Control may be
configured independently for either TOGGLE or ON/OFF mode.
Press and release the button three times rapidly while the LED is
ON.
If the Wall Mount Remote Control channel was in TOGGLE mode, it
will change to the ON/OFF mode.
If the Wall Mount Remote Control channel was in the ON/OFF
mode, it will change to TOGGLE mode.
DELETING A REMOTE CONTROL CHANNEL
A Wall Mount Remote Control channel programmed into an
Omni-Bus receiving device may be deleted from that device by
following the procedure below:
1. Place the receiving device into the programming mode. This is
normally done by pressing and holding the button on the
receiving device until the receiving device LED starts flashing
continuously. (See receiving device user guide for more
information).
2.
3. Exit the programming mode on the receiving device. (See
receiving device user guide for more information).
Press and hold the appropriate channel button
on the Wall Mount Remote Control until the
indicator LED turns on without flashing. (this
operation takes approximately 20 seconds).
Release the button.
Press and hold the appropriate button on the
Wall Mount Remote Control for exactly 14
confirmation signal from the receiving device.
(See receiving device user guide for more
information).
REMOTE CONTROL BATTERY REPLACEMENT
When the indicator LED does not function when the button is
pressed, the battery needs to be replaced.
The Wall Mount Remote Control uses one type 23A 12V battery.
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.