INSTALLATION
Manual Type 6.2.0.1-RF
“Panasonic Compatible” Unit with Essex
“S-12 Stand - Alone” Keypad
For Models
400-S12-PAN 401-S12-PAN
403-S12-PAN 404-S12-PAN
410-S12-PAN 411-S12-PAN
Specifications
Communication
For use with all Panasonic KSUs with door phone
card. This unit is a replacement for the Panasonic
KXT-30865 door phone.
INSTRUCTIONS
Access Control
Essex “stand-alone” 12 button keypad
1 relay plus 2 grounding outputs
(external relays required)
500 users
12 VDC power supply included
Intercom to KSU
Not Used
12 VDC input (for camera and keypad)
NO, COM, NC relay connections
Keypad case ground
Remote bypass terminals (activate relay)
Connect tamper switch to alarm (optional)
501 E. Goetz Ave.
Santa Ana, Ca 92707
www.eholovision.com
Ph. 714-434-6904
Fax 800-362-0002
HOLOVISION
Loop for Strike Power
Cut for NO Contact Closure
400 Series “S-12” Junction Board

Essex Keypad Wiring
In
e
n
i
L
O
C
KSU
DC Out for Gate Strike
To Ph on e s
Strike 1
Door 1
12vDC
1.5 A
Gate Strike
NOTE: MOV (metal oxide varistor) is the small red component which is included. Its purpose is to absorb “inductive kick
back” which can be created when power is removed from the strike.
Loop is required from DC positive to contact common for DC voltage to strike.
Page 2 Type 6.2.0.1-RF
*M
OV
AC Loop for Strike
Cut for NO Contact Closure
i
s
r
ec
o
m
m
e
nd
e
d
Remote
Bypass
Button

Essex Keypad Wiring
In
e
n
i
L
O
C
KSU
Contact Closure for Gate Operation
To Ph on e s
Strike 1
Door 1
12vDC
1.5 A
Page 3 Type 6.2.0.1-RF
AC Loop for Strike
Cut for NO Contact Closure

Programming the Essex Keypad
Set Keypad Illumination to ON ALL OF THE TIME
STEP ACTION BEEP Red LED Green LED
1 Remove power
2 Jumper the “CONFIG” pins on the rear of the keypad . V = 12
3 Apply 12 VDC power to red and black wires Quadruple Beep Flash Solid
4 Enter
5 Enter
6 Remove power
7 Remove “CONFIG” jumper
8 Reapply power
followed by
9 9
2 1 4
#
followed by
Double Beep Flash Solid
#
Triple Beep Flash Solid
Set Master Code
STEP ACTION BEEP Red LED Green LED
1
2 Enter
3 Enter
4 Enter new master code, followed by
5 Enter
6 EXAMPLE: old code is 123, new code is 456
The default Master Code is
This can be changed to a unique code 3 - 8 digits long
3 1 2 3 #
*
1
#
* *
“123”
#
.
Double Beep Fast Flash Solid
Double Beep Fast Flash Slow Flash
Triple Beep Fast Flash Solid
Double Beep
3 1 2 3 # 1 # 4 5 6 #
*
* *
Note: If the User ID, or User Code/PIN has already been assigned, you will hear one long beep when # is entered.
In this case, choose a different User ID / PIN, or see the instructions for changing or deleting codes.
DEFAULT USER CODE & MASTER CODE IS “123#”
TYPE 6.2.0.1-RF Page 4

Programming the Essex Keypad
Set User Codes
STEP ACTION BEEP Red LED Green LED
1 The Master Code is necessary to do this step.
2 Enter
3 Enter
4 Enter 1st User ID (1-500), followed by
5 Enter 1st User Code/PIN, followed by
6 Enter #to complete User 1 programming Triple Beep Slow Flash Slow Flash
7 Enter 2nd User ID (1-500), followed by
8 Enter 2nd User Code/PIN, followed by
9 Enter #to complete User 2 programming Triple Beep Slow Flash Slow Flash
10 Enter
Example for entering user code 1 and 2- * 1 1 2 3 # 1 # 1# 4 5 6 # # 2 # 7 8 9 # # * * * *
Changing User Codes - using User ID
Master Code “123” is used as an example.
1 1 2 3
*
1
#
#
#
#
#
#
* * * *
Double Beep Slow Flash Solid
N
N
N
Double Beep Slow Flash Slow Flash
Double Beep Slow Flash Fast Flash
Double Beep Slow Flash Fast Flash
N
Double Beep Slow Flash Fast Flash
Double Beep Slow Flash Fast Flash
Double Beep X 2
STEP ACTION BEEP Red LED Green LED
1 The Master Code is necessary to do this step.
Master Code “123” is used as an example.
2 Enter
3 Enter
4 Enter User ID to be changed (1-500), followed by
5 Enter new User Code/PIN, followed by
6 Enter #to complete programming Triple Beep Slow Flash Slow Flash
7 Enter
Example for changing user code 1- * 1 1 2 3 # 2 # 1 # 7 8 9 # # * * * *
1 1 2 3
*
2
#
#
#
#
N
* * * *
* Note: If the User ID, or User Code/PIN has not been assigned, you will hear one long beep
N
Double Beep Slow Flash Solid
Double Beep Slow Flash Slow Flash
Double Beep Slow Flash Fast Flash
Double Beep Slow Flash Fast Flash
Double Beep X 2
when # is entered.
TYPE 6.2.0.1-RF Page 5

Programming the Essex Keypad
Deleting User Codes - using User Code/PIN
STEP ACTION BEEP Red LED Green LED
1 The Master Code is necessary to do this step.
In this example, the Master Code is 123
2 Enter
3 Enter
4 Enter User Code/PIN to be changed, followed by
5 Enter new User Code/PIN, followed by
6 Enter #to complete programming Triple Beep Slow Flash Slow Flash
7 Enter
Example for deleting user code # 456- * 1 1 2 3 # 5 # 4 5 6 # 7 8 9 # # * * * *
Deleting User Codes - using User ID
1 1 2 3
*
5
#
* * * *
#
N
#
#
Double Beep Slow Flash Solid
Double Beep Slow Flash Slow Flash
Double Beep Slow Flash Fast Flash
Double Beep Slow Flash Fast Flash
Double Beep X 2
STEP ACTION BEEP Red LED Green LED
1 The Master Code is necessary to do this step.
2 Enter
3 Enter
4 Enter 1st User ID to be deleted (1-500), followed by
In this example, the Master Code is 123
1 1 2 3
*
4
#
#
Double Beep Slow Flash Solid
Double Beep Slow Flash Slow Flash
N
#
Triple Beep Slow Flash Fast Flash
5 Enter 2nd User ID to be deleted (1-500), followed by
.
6 Enter
Example for deleting user ID 1 and 2- * 1 1 2 3 # 4 #1 # 2 # * * * *
* * * *
N
* Note: If the User ID, or User Code/PIN has not been assigned, you will hear one long beep
when # is entered.
#
N
Triple Beep Slow Flash Fast Flash
Double Beep X 2
Page 6 TYPE 6.2.0.1-RF

Programming the Essex Keypad
Reset Keypad to Factory Defaults--- This is not normally necessary, but can be done as follows
STEP ACTION BEEP Red LED Green LED
1 Remove power
2 Jumper the “CONFIG” pins on the rear of the keypad
3 Apply 12 VDC power to red and black wires ONLY Quadruple Beep Flash Solid
5 Enter
6 WAIT about 4 seconds Quadruple Beep Flash Solid
7 Enter
8 Remove power
9 Remove “CONFIG” jumper
10 Reapply power
Setting Main Relay Opening Time
0 0 9 9
9 9
#
#
Double Beep Flash 3 Sec Flash
Triple Beep Flash Solid
STEP ACTION BEEP Red LED Green LED
1 The default Master Code is “123”.
This can be changed to a unique code 3 - 8 digits long.
2 Enter
3 Enter
*3 1 2 3
2
#
#
Double Beep Slow Flash Solid
Double Beep Slow Flash Slow Flash
4 Enter the desired activation time in Seconds followed by
5 Enter
6 Example:
to exit
* *
2 # 10 #
(10 second activation time)
* *
Note: If the User ID, or User Code/PIN has not been assigned, you will hear one long beep
when # is entered.
#
Triple Beep Slow Flash Solid
Page 7 TYPE 6.2.0.1-RF

www.eholovision.com
501 E. Goetz Ave.
Santa Ana, Ca 92707
Ph. 714-434-6904
Fax 800-362-0002