1.2 Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(866) 759-1577
2. INSTALLATION
2.1 Tools and Material Required.
DESCRIPTION USE 1/8” Hex wrench Set screws (mounting, optical assy.)
3/8" nut driver or medium ballast mounting screws, reflector screws, flat blade screw driver ballast door screw Torque wrench Set screws Pipe Thread Sealant mounting pipe threads ¾” Socket wrench Luminaire mounting screws
Figure 1
Table 1. Installation Tools and Materials
1. INTRODUCTION
1.1 Product Description.
The Milwaukee Lantern Luminaire has been designed to distribute specific patterns of light on the surface below. All optics have street side orientation on the flange of the refractor.
The Milwaukee Lantern luminaire is designed for easy maintenance.
The lamp can easily be replaced by loosening a screw and swinging down the refractor door.
Electrical components are mounted on an easily accessible ballast assembly door.
GR2008
GR2003
2.2 Luminaire Installation.
2.2.1
Feed supply leads from pole through wireway hole.
2.2.2
Attach optical assembly to Arm assembly. Apply pipe thread sealant to the first 4 male threads on the mounting pendant, make sure to apply completely around the threaded pendant. Force the sealant into the threads using a finger or similar tool. See Figure 2. Thread the mounting assembly onto the pipe threads. Tighten by hand until the threads begin to feel tight. Tighten at least one additional full rotation and orient the reflector door screw toward the street. Refractor is marked "street side." Tighten set screws at threaded entry hole to 10-12 foot pounds.
IM-182
Caution
Field application of Pipe Thread Sealant is
required. Failure to properly apply pipe thread
sealant could cause this unit to leak.
Figure 2
GR1060
2.2.3
Loosen ballast assembly door screw, remove two hinge screws at the rear of the ballast assembly door on the outside of the arm to remove ballast assembly door.
2.2.4
Connect the wires from the optical assembly to the wires from the arm assembly. Connect green wire to green wire, white wire to white wire, and black wire to black wire.
2.2.5
With ballast assembly door removed, attach and level luminare to the pole using mounting bolt pattern at the rear of the arm assembly. On units using a tenon fitter tighten set screws at the base of the tenon fitter to 10-12 foot pounds. See figure 3.
2.2.6
Connect electrical supply wires to the terminal block inside the arm assembly. The terminals are marked “L1” (line1). “G” (Ground). “L2” (line2). If one of the supply wires is electrically neutral, it should be connected to terminal “L2”.
2.2.7
Open the wire chamber cover by loosening the door screw. Connect the male wiring harness connector from the optical assy. to the female wiring harness connector from the ballast assy. close the ballast compartment door and tighten the screw. See figure 4.
2.2.8
Tighten door screw on ballast assembly door to 10-12 foot pounds. See figure 4.
2.2.9
Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
3. MAINTENANCE
3.1 Relamping and Cleaning.
3.1.1
Wipe off exterior dirt and debris.
3.1.2
Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
3.1.3
Remove lamp.
3.1.4
Wipe out the refractor interior with a clean dry cloth.
3.1.5
Install new lamp of correct wattage and type. Tighten the lamp carefully but securely.
3.1.6
Close lamp chamber by swinging up the refractor and tightening the refractor door screw.
3.1.7
Energize the luminaire. Check for proper operation.
3.2 Replacement Ballast Assembly.
3.2.1
Loosen ballast door screw at optical assembly end of luminaire. Refer to Figure 4.
Figure 3
Figure 4
3.2.2
Swing down ballast assembly door with one hand and use
other hand to disconnect the male wiring harness connector.
3.2.3
Remove ballast assembly door refer to section 2.2.3
3.2.4
Unscrew (2) ballast mounting strap screws located to the rear of the ballast assembly door they are the screws attaching the ballast strap to the door assembly, remove ballast.
3.2.5
Unpack replacement ballast assembly. Check voltage leads.
3.2.6
Replace the ballast assembly and reinstall the ballast­mounting strap.
3.2.7
Reconnect the male wiring harness connector to the female wiring harness connector, reattach the ballast door assembly and swing ballast assembly door completely closed
3.2.8
Tighten ballast door screw to 10-12 ft.-lbs.
3.2.9
Energize the luminaire. Check for proper operation.
GR1101
GR2004
4. Limited Warranty and Limitation of Liability
The Holophane limited warranty and limitation of liability is published in the "Terms and Conditions" section of the current Holophane buyer's guide, and is available from your local Holophane sales representative.
Acuity Lighting Group, Inc. Oakwood Ave., Newark, OH 43055
IM-182 7/02 ©2002 Acuity Lighting Group Inc.
Visit our web site at www.holophane.com
Printed in USA
®
IM-182
Loading...