HOLOPHANE
HOLOPHANE
HOLOPHANEHOLOPHANE
MILWAUKEE LANTERN Installation and
Maintenance
Manual
AFTER INSTALLATION DELIVER THIS
MANUAL TO OWNER
IMPORTANT SAFETY INSTRUCTIONS
WARNING
CAREFULLY BEFORE ATTEMPTING TO INSTALL OR
MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY
QUALIFIED PERSONNEL.
WARNING
POWER IS DISCONNECTED
FROM THE FIXTURE BEFORE INSTALLING
OR MAINTAINING THE FIXTURE.
WARNING
OPERATING AND MAINTENANCE INSTRUCTIONS.
MAY RESULT IN DEATH, INJURY OR SIGNIFICANT
– READ THESE INSTRUCTIONS
– BE CERTAIN THAT ALL ELECTRICAL
– FOLLOW LAMP MANUFACTURER’S
FAILURE TO FOLLOW THESE WARNINGS
PROPERTY DAMAGE.
1.2 Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(866) 759-1577
2. INSTALLATION
2.1 Tools and Material Required.
DESCRIPTION USE
1/8” Hex wrench Set screws (mounting, optical assy.)
3/8" nut driver or medium ballast mounting screws, reflector screws,
flat blade screw driver ballast door screw
Torque wrench Set screws
Pipe Thread Sealant mounting pipe threads
¾” Socket wrench Luminaire mounting screws
Figure 1
Table 1. Installation Tools and Materials
1. INTRODUCTION
1.1 Product Description.
• The Milwaukee Lantern Luminaire has been designed to
distribute specific patterns of light on the surface below. All
optics have street side orientation on the flange of the refractor.
• The Milwaukee Lantern luminaire is designed for easy
maintenance.
• The lamp can easily be replaced by loosening a screw and
swinging down the refractor door.
• Electrical components are mounted on an easily accessible
ballast assembly door.
GR2008
GR2003
2.2 Luminaire Installation.
2.2.1
Feed supply leads from pole through wireway hole.
2.2.2
Attach optical assembly to Arm assembly. Apply pipe thread
sealant to the first 4 male threads on the mounting pendant, make
sure to apply completely around the threaded pendant. Force the
sealant into the threads using a finger or similar tool. See Figure 2.
Thread the mounting assembly onto the pipe threads. Tighten by
hand until the threads begin to feel tight. Tighten at least one
additional full rotation and orient the reflector door screw toward the
street. Refractor is marked "street side." Tighten set screws at
threaded entry hole to 10-12 foot pounds.
IM-182

Caution
Field application of Pipe Thread Sealant is
required. Failure to properly apply pipe thread
sealant could cause this unit to leak.
Figure 2
GR1060
2.2.3
Loosen ballast assembly door screw, remove two hinge
screws at the rear of the ballast assembly door on the outside of the
arm to remove ballast assembly door.
2.2.4
Connect the wires from the optical assembly to the wires
from the arm assembly. Connect green wire to green wire, white
wire to white wire, and black wire to black wire.
2.2.5
With ballast assembly door removed, attach and level
luminare to the pole using mounting bolt pattern at the rear of the
arm assembly. On units using a tenon fitter tighten set screws at the
base of the tenon fitter to 10-12 foot pounds. See figure 3.
2.2.6
Connect electrical supply wires to the terminal block inside the
arm assembly. The terminals are marked “L1” (line1). “G” (Ground).
“L2” (line2). If one of the supply wires is electrically neutral, it should
be connected to terminal “L2”.
2.2.7
Open the wire chamber cover by loosening the door screw.
Connect the male wiring harness connector from the optical assy. to
the female wiring harness connector from the ballast assy. close the
ballast compartment door and tighten the screw. See figure 4.
2.2.8
Tighten door screw on ballast assembly door to 10-12 foot
pounds. See figure 4.
2.2.9
Open lamp chamber by loosening the refractor door screw
and swing down refractor. Refer to Figure 1.
3. MAINTENANCE
3.1 Relamping and Cleaning.
3.1.1
Wipe off exterior dirt and debris.
3.1.2
Open lamp chamber by loosening the refractor door
screw and swing down refractor. Refer to Figure 1.
3.1.3
Remove lamp.
3.1.4
Wipe out the refractor interior with a clean dry cloth.
3.1.5
Install new lamp of correct wattage and type. Tighten
the lamp carefully but securely.
3.1.6
Close lamp chamber by swinging up the refractor and
tightening the refractor door screw.
3.1.7
Energize the luminaire. Check for proper operation.
3.2 Replacement Ballast Assembly.
3.2.1
Loosen ballast door screw at optical assembly end of
luminaire. Refer to Figure 4.
Figure 3
Figure 4
3.2.2
Swing down ballast assembly door with one hand and use
other hand to disconnect the male wiring harness connector.
3.2.3
Remove ballast assembly door refer to section 2.2.3
3.2.4
Unscrew (2) ballast mounting strap screws located to the rear
of the ballast assembly door they are the screws attaching the ballast
strap to the door assembly, remove ballast.
3.2.5
Unpack replacement ballast assembly. Check voltage
leads.
3.2.6
Replace the ballast assembly and reinstall the ballastmounting strap.
3.2.7
Reconnect the male wiring harness connector to the female
wiring harness connector, reattach the ballast door assembly and
swing ballast assembly door completely closed
3.2.8
Tighten ballast door screw to 10-12 ft.-lbs.
3.2.9
Energize the luminaire. Check for proper operation.
GR1101
GR2004
4. Limited Warranty and Limitation of Liability
The Holophane limited warranty and limitation of liability is published
in the "Terms and Conditions" section of the current Holophane
buyer's guide, and is available from your local Holophane sales
representative.
Acuity Lighting Group, Inc.
Oakwood Ave., Newark, OH 43055
IM-182 7/02 ©2002 Acuity Lighting Group Inc.
Visit our web site at www.holophane.com
Printed in USA
®
IM-182