FEATURES
Dual Position- the air purifier can stand upright or lie on its side.
Also designed to fit with its
back flush against the
wall. When positioning
the unit, please be sure
the air inlet grill, filters
and air outlet are not
blocked to ensure
maximum airflow.
Equipped with GE motor for quieter performance and the added
durability necessary for continuous use.
Filter Life Indicator- The Filter Life Indicator uses a series of lights
to give you an indication of the remaining filter life. When the filters
are new and in good condition, the top light will be illuminated
green. As the filter life progresses, the Filter Life Indicator will move
to yellow. At this point, the carbon and HEPA filters should be
checked. When the Filter Life Indicator light is red, it is time to
change the filters. (On the HAP675RC, there are 2 filter indicator
lights. The first light will be in amber color when the filter is in new
or good condition. Over a period of time, the filter performance will
begin to decrease. At this point, the second light will become red.)
Remote Control/Push Button Controls (For HAP675RC only)
This unit offers a remote control for convenient operation from
anywhere within your room. The push
button control area also allows for easy
operation. The HAP675RC can be
controlled/operated by either the remote
control handset or the manual push buttons
on the unit. The remote control has 5
buttons – 4 speeds settings and power off. The remote control
requires 2 AAA batteries.
BATTERY WARNING:
• DO NOT mix old and new batteries.
• DO NOT mix alkaline, standard (carbon-zinc), or rechargeable
(nickel-cadmium) batteries.
When using electrical appliances, basic safety precautions should
always be followed to reduce the risk of fire, electric shock, and injury
to persons, including the following:
1. Read all instructions before using appliance.
2. To avoid fire and shock hazard, plug the appliance directly into a
120V AC electrical outlet.
3. If the filter is covered by a bag when shipped: remove plastic bag
over filter before use.
4. Keep the cord out of heavy traffic areas. To avoid fire hazard
NEVER put the cord under rugs, near heat registers, radiators,
stoves or heaters.
5. To protect against electrical hazards DO NOT immerse in water or
other liquids. Do not use near water.
6. Close supervision is necessary when any appliance is used by, or
near children or by disabled persons.
7. Always unplug the air purifier before moving it, opening the grill,
changing the filters or whenever the air purifier is not in use. Be
sure to pull by the plug and not the cord.
8. NEVER drop or insert any object into any openings.
9. Do not operate any appliance with a damaged cord or plug, if
motor fan fails to rotate, after the appliance malfunctions, or if it
has been dropped or damaged in any manner. Return appliance
to manufacturer for examination, electrical or mechanical
adjustment or repair.
10.Use appliance only for the intended household use as described in
this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock or injury to persons.
The use of attachments not recommended or sold by the Holmes
Group may cause hazards.
11.Do not use outdoors.
12.Never block the air openings, or place on soft surface, such as bed
or sofa, as this could cause the unit to tip over thus blocking the
air intake opening.
13.Keep unit away from heated surfaces and open flames.
14.DO NOT attempt to repair or adjust any electrical or mechanical
functions on this unit. Doing so will void your Warranty. The inside
of the unit contains no user serviceable parts. All servicing should
be performed by qualified personnel only.
15.WARNING: To reduce the risk of fire or electrical shock, DO NOT
use this air purifier with any solid-state speed control device.
16.DO NOT place anything on top of the unit.
CORD AND PLUG INSTALLATION SAFETY INSTRUCTIONS
The length of cord used on this appliance was selected to reduce the
hazards of becoming tangled in, or tripping over a longer cord. If a
longer cord is necessary an approved extension cord may be used.
The electrical rating of the extension cord must be equal to or greater
than the rating of the air purifier. Care must be taken to arrange the
extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
Congratulations on your purchase of an Air Purifier. Your Air Purifier
has an attractive stylish design. Its versatility and quiet operation
make this unit perfect for both the home and the office.
Harmony®BACKGROUND
First, thank you for choosing a Holmes Harmony®Air Purifier. The
Harmony
®
Air Purifier was created because consumers, like you,
provided a lot of feedback about what you wanted in an air purifier.
With the features consumers want in mind, we worked with sound
experts and engineers to make the unit quieter and smaller, with
more advanced technologies. We designed a patented modular filter
system for easier filter replacement. The result is an air purifier that
is in harmony with your environment--it cleans your air and fits your
life.
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
FEATURES - OPERATIONSFEATURES - OPERATIONS
PRE-OPERATING INSTRUCTIONS
NOTE: The door should not be opened when the unit is on its side.
1. After removing the unit from the box, take the plastic covering
off the unit and properly dispose of it.
2. Place unit with air intake grill pointing up.
3. Open the door of the air purifier.
4. The carbon filters, which are packed in a plastic bag in the box,
should be removed from plastic bag and then placed on each of
the HEPA filters. The plastic tabs on the HEPA filter will hold the
carbon in place (see Figure 1).
5. Close the air purifier door by pushing firmly against the right
hand side of the door.
OPERATING INSTRUCTIONS
1. Select location where air intake grill and filtered air outlet are
not obstructed.
2. Plug into a 120V AC electrical outlet.
3. The air purifier is now ready for use. Set the air purifier to the
desired speed setting; High (IIII), Medium (III), Low (II) or Sleep (I)
by turning the speed control knob. (On the HAP675RC, you will
need to press the ON/OFF button to turn the unit on. ON will
automatically cycle to the highest setting. Use the speed button to
set the desired speed: High (IIII), Medium (III), Low (II) or Sleep
(I).)
For continuous use, it’s recommended to operate the air purifier at
the MEDIUM setting. For quieter operation or use in a bedroom,
select the LOW setting. When high levels of air pollution are present,
select the HIGH setting to quickly circulate and filter the room air.
Figure 3
Figure 2
Figure 1
F
G
H
I
D
C
A
B
E
A. HEPA FILTER
B. CARBON FILTER
C. HANG TABS
D. AIR INTAKE GRILL
E. FILTERED AIR
OUTLET
F. SPEED CONTROL
KNOBS
G. FILTER LIFE
INDICATOR
H. RESET BUTTON
I. POWER CORD
(not shown)
THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC
(Alternating Current) PLUG (a plug having one blade wider
than the other). This plug will fit into the power outlet only
one way. If the plug does not fit fully into the outlet, reverse
the plug. If it still does not fit, contact qualified personnel to
install the proper outlet.
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY
FILTER REPLACEMENT INSTRUCTIONS
1. On average, HEPA filters need to be replaced every 12-18
months. Carbon filters need to be replaced every 3-6 months.
Filter life will vary depending on air quality and usage.
2. Turn off and unplug the air purifier before attempting to replace
the filters.
3. Remove each of the filters from the unit by pulling gently towards
you.
4. To replace the carbon filter, simply remove the old carbon filter
and insert a new carbon in its place, using the plastic tabs as a
guideline (see Figure 1).
5. To replace the HEPA filter, discard the old HEPA filters. DO NOT
attempt to clean. Put the carbon filter back on the new HEPA filter.
Insert the new HAPF600 HEPA filter into the unit, by sliding it onto
the hang tabs. (see Figure 2)
6. After replacing the HEPA filters, RESET the Filter Life Indicator by
inserting a small object (such as a pin or paper clip) into the hole
below the red filter change light marked RESET
.
REPLACEMENT FILTERS ARE AS FOLLOWS:
HAPF600 HEPA Filter
HAPF600D HEPA Filter (2 pack)
HAPF60 Carbon Filter
These filters can be purchased at a retailer near you or by calling
1-800-5-HOLMES.
NOTE: Carbon and HEPA Filters are not washable and should be
replaced at the recommended intervals.
HAP675RC shown