4. This model utilizes a
hang tab and filter clip.
The clip can only be
attached to the tabs on
the filter one way only.
The filter clip should
easily slide onto the filter
hang tab with only a
small amount of pressure.
DO NOT use force while
attaching the clip to the
filter (See Fig. 2). Align
the clip on the top of the
HEPA-type filter with the
rails on the inside of the
air purifier unit. Gently
slide the filter onto the
rail (See Fig. 3).
NOTE: The pleated material and rubber gasket should be
facing towards the unit when applied.
5. If the filters are enclosed in plastic bags please
ensure that the bags are removed prior to
operation.
6. Replace air inlet grill back onto unit securely.
7. The filter reminder dial should be set ahead 3 months,
to indicate when the filter conditions should be checked
and replaced. (See FILTER REPLACEMENT INSTRUCTIONS
for more information. )
NOTE: Do not point air outlet towards a wall.
OPERATING INSTRUCTIONS
1. Plug into a 120V AC electrical outlet.
2. Select the desired operating speed; HI ( ), MEDIUM ( ),
LOW ( ), by turning Speed Control Knob to the
appropriate setting.
3. To release negative ions into the filtered air, turn the
Ionizer Knob to ON ( ) and the light will illuminate.
4. The ionizer will not work unless the unit is running.
5. For optimum air filtration, it is recommended to operate
the air purifier continuously. Its rugged motor has been
designed to give many years of use.
CLEANING/MAINTENANCE INSTRUCTIONS
1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned with a soft,
clean dampened cloth.
3. The rear air inlet grill can be removed and washed in
warm soapy water (not dishwasher safe). Dry before
replacing in the unit.
4. The filtered air outlet can be cleaned of dust with a
small, soft brush.
5. If you wish to clean the inside of the air purifier, please
only use a dry, soft cloth to wipe it down.
WARNING: Do not allow moisture to come in contact with
the main housing of the air purifier.
FILTER REPLACEMENT INSTRUCTIONS
1. Every few weeks, check the condition of the pre-filter.
2. Remove the rear grill. Examine the foam pre-filter. If
the pre-filter has collected a noticeable amount of dust
or lint, remove it from the inlet of the grill and wash it
in warm soapy water. Rinse and drip dry the pre-filter
thoroughly before replacing it in the inlet of the grill.
3. With the rear grill removed, remove the used HEPA-type
cartridge and dispose of it in the garbage. DO NOT try
to wash and re-use the HEPA-type filter. Replace with a
new HEPA-type HAPF30 filter, removing the protective
polybag before inserting into the air purifier.
4. Align the clips on the top of your HEPA-type filter with
the rails on the inside of the unit. Gently slide the filter
onto the rail.
NOTE: The pleated material and rubber gasket should be
facing towards the unit when installed.
5. Filter Life – Under normal conditions of continuous use,
the HEPA-type filter will operate efficiently for 3-6
months.
6. Replacement filters (HAPF30) are available from your
local supplier or by calling 1-800-253-2764.
7. The filter reminder dial should be set ahead 3-6 months
depending on usage.
Thank you for choosing a Holmes®air purifier. To ensure the
best performance from your air purifier, please read and
save the following instructions.
IONIZER
Your air purifier has an independently controlled ionizer,
which, when turned on, releases negative ions into outgoing
filtered air. Ions are tiny particles that carry a positive or
negative charge. These ions exist naturally around us, in the
air, water, and ground. Both positive and negative ions are
colorless, odorless, and completely harmless. Negative ions
help the air purification process by attaching themselves to
very small airborne particles in the room.
These particles take on a negative charge and may join with
positively charged particles such as dust, pollen, smoke, and
pet dander to form larger particles that are then more
readily captured by the filter system, or may be attracted to
positively charged surfaces throughout the home, like walls
or floors. This may occur more frequently when the filter is
nearing the end of its functional life expectancy and is able
to capture less of the charged particles.
You may also note after extended use, that dust has
collected around the grills or front panel. This is from the
ionization affect caused by the negative ions exiting from
the air outlet. This is additional evidence of the air cleaning
effectiveness of negative ions. The dust can be easily
removed with a clean, damp cloth or soft brush.
Finally, using your ionizer may result in an occasional
popping or cracking sound. This is a normal sound, generally
caused by a small build-up of ions that, when discharged,
cause the popping or cracking sound.
NOTE: It is important to replace the HEPA-type filters at the
recommended intervals.
Using the ionizer in conjunction with dirty filters may result
in dirty particles exiting the air purifier and being attracted
to walls, carpets, furniture, or other household objects. These
dirty particles may prove very difficult to remove. Homes
with excessive amounts of pet dander, dust, or smoke may
decrease the life expectancy of the HEPA-type filtration
system and may interfere with the ionization process. You
may want to run the Ionizer less often and check the
condition of the HEPA-type filter(s) more frequently in order
to reduce particles from being attracted to surfaces
throughout your home as mentioned above.
PRE-OPERATING INSTRUCTIONS
1. Carefully unpack your air purifier. Select a firm level
place where there are no obstructions to the air inlet or
filtered air outlet. A good location in a room is
approximately 1 foot away from the wall, in a central
location of your home.
2. Pull air inlet grill towards you by grasping the finger
tabs and pulling forward .
3. Remove the HEPA-type filters by gripping on both sides
and pulling forward.
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
FEATURES
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
• Read all instructions before using the appliance.
•To avoid fire or shock hazard, plug the appliance
directly into a 120V AC electrical outlet.
• If the filter is covered by a bag when shipped: Remove
plastic bag before use.
• Keep the cord out of heavy traffic areas. To avoid fire
hazard, NEVER put the cord under rugs, near heat
registers, radiators, stoves, or heaters.
•To protect against electrical hazards, DO NOT immerse
in water or other liquids. Do not use near water.
• Close supervision is necessary when any appliance is
used by or near children, or disabled persons.
• Always unplug the air purifier before moving it, opening
the grill, changing the filters, cleaning, or whenever the
air purifier is not in use. Be sure to pull by the plug and
not the cord.
• NEVER drop or insert any object into any openings.
• DO NOT operate any appliance with a damaged cord or
plug, if motor fan fails to rotate, after the appliance
malfunctions, or if it has been dropped or damaged in any
manner. Return appliance to manufacturer for examination,
electrical or mechanical adjustment, or repair.
• Use appliance only for intended household use as described
in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to
persons. The use of attachments not recommended or
sold by JCS/THG, LLC may cause hazards.
• DO NOT use outdoors.
• NEVER block the air openings, grills/outlets or place on a
soft surface such as a bed or sofa, as this could cause the
unit to tip over, blocking the Air Intake Opening/Grill.
• Keep unit away from heated surfaces and open flames.
• DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed by
qualified personnel only.
• WARNING:To reduce the risk of fire or electric shock,
DO NOT use this air purifier with any solid-state speed
control device.
• DO NOT place anything on top of unit.
PLEASE READ AND SAVE
THESE IMPORTANT SAFETY
INSTRUCTIONS
CORD AND PLUG INSTALLATION SAFETY
INSTRUCTIONS
The length of cord used on this appliance was selected to reduce
the hazards of becoming tangled in, or tripping over a longer
cord. If a longer cord is necessary, an approved extension cord
may be used. The electrical rating of the extension cord must be
equal to or greater than the rating of the air purifier. Care must
be taken to arrange the extension cord so that it will not drape
over the countertop or tabletop where it can be pulled on by
children or accidentally tripped over.
Thank you for purchasing this Holmes®product. We
understand the value of quality and are committed to
making superior products that stand the test of time. We
trust this product will exceed your expectations of quality
and reliability. We hope that you enjoy this product and will
consider purchasing another Holmes®product in the future.
To see our full product line or if you have any questions or
comments about this product, please visit our website at:
www.holmesproducts.com.
THIS PRODUCT IS EQUIPPED WITH A POLARIZED PLUG (a plug having one blade wider
than the other). This plug will fit into the power outlet only one way. If the plug does not
fit fully into the outlet, reverse the plug. If it still does not fit, contact qualified personnel
to install the proper outlet.
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY
FEATURES - OPERATIONS
CLEANING/MAINTENANCE
FILTER REPLACEMENT
Air Purifier Model #
Filter Quantity
Needed
Filter # Filter Description
HAP424-U 2 HAPF30 HEPA/Carbon
Fig. 2
Fig. 3
A. Ionizer Knob E. Filtered Air Outlet
B. Filter Reminder Dial F. HEPA-Type Filters
C. Speed Control Knob G. Washable Foam Pre-Filter
D. Ionizer LED H. Air Inlet Grill
Fig. 1
D
E
F
G
H
C
B
A