Holman TD30 Installation Manual

THERMAL VECTION
IL2263
Heat and Hold Drawer
MODEL
TVD30, TVD50
Installation and
Operation
Instructions
1
2
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specications and product design without
notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change without notice. While Star International Holdings Inc., Company exercises good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions
reached as a result of using the specications. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when
you call to ensure a faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business
8:00 am to 4:30 p.m. Central Standard Time
Hours:
Telephone: (800) 264-7827 Local (314) 684-6303
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Service Help Desk
Authorized Service Agent Listing
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com
Mailing Address: Star International Holdings Inc., Company
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
Width
Depth
Height
IL2186
SPECIFICATIONS
Electrical Specications
Model Voltage Watts Amps Cord
TD30
TD50 1370 11.4A
TD30 24"
TD50 36"
120V
Dimensions
Width Depth Height
700 5.8A
29.75" 6.25"
NEMA 5-15P
CAUTION
WARNING
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
VOLTAGE
The thermal vection is equipped for use on the voltage specied on the nameplate.
DO NOT CONNECT TO ANY OTHER TYPE OF CURRENT OR THE MACHINE WILL BE SERIOUSLY DAMAGED.
3
OPERATION
START-UP
When the unit is rst turned on it will begin the PRE-HEAT mode. The current hold temperature will be displayed for 3 seconds, then “PHT” (PREHEAT) will ash along with the “HEAT ON” lamp until the unit has reached its preset hold temperature. When this has been reached, the audible alarm will beep 3 times, the “HEAT ON” lamp will stop ashing and the display will read “RDY”.
COOKING
Load the unit with the product, (thawed not frozen) Press the “COOK” button to begin. The “COOK” light will remain on and the Temp light will be on as the unit call for heat. “COOK” will display for 3 seconds, and then the internal cook timer will begin counting down.
Close the drawer.
When the timer reaches 00:00, the audible alarm will beep 3 times.
Then you have two options:
1. Remove the product immediately from the Thermal Vection and place in on your preheated roller grill for display, then press the “RESET” button. This will take the temperature back to the PRE-HEAT mode temperature, until you are ready to cook again.
2. Leave the product in the Thermal Vection until you are ready to serve, the unit will maintain the HOLD temperature and an internal timer will begin to count down, after 3 hours an audible alarm will sound for 3 seconds and the display will ash “DoNE” until the RESET button is pressed. At
this time the remaining product left in the unit has expired and needs to be discarded.
READING TEMPERATURE
At any point the operator can view the actual temperature by pressing the “TEMP” button. The reading will be displayed in the temperature mode (°F or °C) which is programmed.
PROGRAMMING THE TEMPERATURE MODE
The temperature mode can be changed from °F to °C or °C to °F by pressing and holding the “TEMP” button while turning on the main power switch. The set-point temperature that is displayed will be in
the changed temperature mode.
PROGRAMMING HOLD / PREHEAT TEMPERATURE MODE ( F / C)
The HOLD / PREHEAT temperature and hold time can be programmed using the following steps. The default HOLD temp and TIME are 140°F (60°C) for 3 hours.
1. Simultaneously press and hold the “TEMP” and “HOLD” buttons for approx 3 seconds.
2. The display will show “----“
3. Release the buttons.
4. Enter the 4 digit security code. (4,3,2,1)
5. Once completed, the current hold / preheat temperature will be displayed.
6. To increase or decrease the temperature use the “UP” or “DOWN” arrows.
7. Press the “TEMP” button to save the change.
8. The current time duration for the HOLD mode is now displayed.
9. Use the “UP” or “DOWN” arrows to increase or decrease the HOLD time.
10. Press the “TEMP” button to save the new HOLD time.
11. Press the “TEMP” button again to exit the programming mode.