HMS-16APR
SATELLITE MULTI-SWITCH
Satellite Multi-Switch
950-2150 MHz
The HMS-16APR is a 14V/18V satellite multi-switch used in
all applications that require satellite I.F. distribution from
950-2150 MHz . It will allow the user to take two LNB
outputs and provide inputs to a maximum of sixteen
receivers. The HMS-16APR routes any of the inputs bo any
of the outputs by utilizing the 14V/18V switching control
from the satellite receivers. The HMS-16APR provides an
excellent way to simplify any SMATV installation.
Provides LNBV and LNBH switching for
16 receivers
Power adapter supplies power t o LNB’s
Input selected by 14V/18V from satellite
receiver employing right and left hand
circular polarization
Ideal for smaller syatems
MODEL HMS-16APR
-1-

HOLLAND ELECTRONICS LLC
LIMITED WARRANTY
Holland Electronics LLC, warrants that the product enclosed with this Limited
Warranty statement will conform to the manufacturer’s specifications and be free of
defects in the workmanship and material for a period of two years(2) from the date of
original purchase.
WARRANTY PROCEDURE:
If the product appears to be defective contact Holland Electronics LLC. at (805) 339-
9060. We will analyze the problem and offer solutions to prevent removing the unit
from service. If the unit is to be returned for evaluation, you will be issued a Return
Material Authorization (RMA) number .
Holland Electronics LLC will, at its option , repair or replace the defective unit . under
warranty , without charge for parts or labor. This repair will be subject to charges if
signs of tampering or misuse are detected .Incoming shipping costs will be the
customers responsibility . Returns will not be accepted without an RMA number .
The warranty and remedy provided above are exclusive and in lieu of all other express
warranties and unless stated herein , any statements or representations made by any
other person or firm are void. The duration of any implied warranties of
merchantability or fitness for a particular purpose on this product shall be limited to the
duration of the express warranty set fourth above. Except as provided in this written
warranty, Holland Electronics LLC shall not be liable for any loss, inconvenience or
damage, including direct, special , incidental, or consequential damages, resulting from
the use or inability to use this product, whether resulting from breach of warranty or
any other legal theory.
Some states do not allow limitations on how long an implied warranty lasts and some
states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation and exclusion may apply to you.
This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.
To arrange for Warranty Service: Call Holland Electronics LLC. (805)339-9060
-2-

HMS-16APR
LNB Output Frequency:
950-2150 MHz
Insertion Loss:
950 – 1750 MHz -8 dB typical
1750 – 2050 MHz -13 dB typical
2050 – 2150 MHz -16 dB typical
Isolation:
LNBV to LNBH -35 dB typical
Output to Output -12 dB typical
Switching Voltage:
13/14 Vdc LNBV
17/18 Vdc LNBH
Power - Wall Adaptor: 117 Vac, 60Hz
Connectors: “F”type
Dimensions: 19”Lx2. 87”Dx1.75”H
INSTALLATION INSTRUCTIONS:
1. Connect the LNBV output and the LNBH output to the LNBV(13/14V) and
LNBH(17/18V) inputs respectively of the HMS-16APR
2. Connect each of the output ports on the front of the unit to the SATELLITE INPUT
of the receiver.
3. Plug the wall adaptor 3.5mm plug into the jack located in the back of the unit. Plug
the adaptor into a 120Vac, 60Hz wall receptacle.
4. Each of the satellite receivers can select programs in either right or left hand
circular polarities . To select a right hand circular polarity, a 13/14 DC voltage is
used and to select a left hand circular polarity, a 17/18 DC voltage is used.
-3-

IMPORTANT!!
WARNING: Holland Electronics LLC does NOT represent
this product to be WATERPROOFED. To reduce risk of
electrical shock, fire hazard, or damage to the unit, do not
expose to rain or moisture.
CAUTION: To prevent electric shock, do not use this plug
with an extension cord, receptacle or other outlet unless the
blades can be fully inserted to prevent blade exposure.
NOTE TO INSTALLER: This reminder calls the system
Installer’s attention to Article 820-22 of the NEC that
provides guidelines for proper grounding and, in particular,
specifies that the cable ground shall be connected to the
grounding system of the building, as close to the point of
cable entry as practical.
WARNING:
TO PREVENT FIRE OR ELECTRICAL SHOCK, DO
NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE
-4-