Hoffman DAH2001A, DAH8001B, DAH8002B, DAH13002C, DAH13001C User Manual

...
Electric Heaters
Rev. D
© 2012 Pentair Technical Products PH 763 422 2211 • hoffmanonline.com 87565511
P/N 28359001
English
INTRODUCTION
1. Before installing the electric heater, read these instructions carefully. Failure to follow these instructions could damage the product or cause a hazardous condition.
WARNING
To avoid electric shock and equipment damage, disconnect any power supplies to the enclosure before installing the electric heater. Do not energize any circuits before all internal and external electrical and mechanical clearances are checked to assure that all assembled equipment functions safely and properly.
GENERAL SAFETY INFORMATION
1. Protect the lead wires from coming in contact with sharp objects, hot surfaces, and/or chemicals.
2. If continuous operation of the heater is essential to the safe functioning of any other equipment, adequate warning devices must be installed to assure safe operation at all times.
CAUTION
Do not use these electric heaters in dusty, dirty, corrosive, or hazardous locations.
Reduce the thermostat from factory setting to a recommended setting not to exceed 75 F for most applications.
Portions of the heater can get hot. Adequate protection must be taken to protect people from potential burns and to protect other components from this heat. Always allow the heater to cool before touching it.
Thermal sensitive devices or materials may need to be located further from the heater than the minimum recommended distance.
Heaters must not be installed on wood or other combustible surfaces.
This heater must only be installed in a totally enclosed enclosure.
- 2 -
© 2012 Pentair Technical Products
PH 763 422 2211 • hoffmanonline.com 87565511
English
LOCATION AND MOUNTING
1. Hoffman electric heaters should be centered as low as possible in the enclosure for optimum heat distribution.
2. It is recommended that the heater be installed on a non-combustible metal panel for optimum performance. It may, however, be mounted on any metal surface.
WARNING: Heaters must not be installed on wood or other combustible surfaces.
3. The heater should be mounted in a vertical position with the terminal block at the bottom and the air outlet openings at the top as shown.
4. The recommended clearances shown by the shadowed area indicates the space that should be kept free of components for safe operation of the heater.
WARNING: Heat sensitive components must not be placed above the heater discharge area.
5. Four 10−32 UNF, self−tapping screws are included for installation.
Vertical Surface Mounting Optional Horizontal Surface Mounting
Watts X D E
DAH1001A, DAH1002A 100 4
DAH2001A, DAH2002A 200 6
DAH4001B, DAH4002B 400 6
DAH13001C, DAH13002C 1300 8
© 2012 Pentair Technical Products
5.00 (127 mm) 3.25 (83 mm)
7.00 (178 mm) 3.50 (89 mm)DAH8001B, DAH8002B 800 8