Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
LXe
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
STANDARD FEATURES
■ 32 racks per hour – LXeH
■ 34 racks per hour – LXeC
■ .74 gallons of water per rack
■ Hot water or chemical sanitation units available
■ Low chemical alert indicators
■ Sense-A-Temp™ booster heater capable of 70°
rise, provided on LXeH models
■ Delime notication with cycle
■ Chemical pump “auto-prime”
■ Service diagnostics
■ Deep drawn stainless steel tank
■ Microcomputer, top mounted controls with
digital cycle/temperature display
HOT AND COLD
MODELS
❑ LXeC
❑ LXeH
ACCESSORIES
❑ Power cord kits
❑ Stainless steel base with 6" legs
❑ 17" stainless steel stand with storage
❑ External caster kit
❑ DWT-L Xe drain water tempering kit
Specications, Details and Dimensions on Back.
■ Revolving upper and lower anti-clogging wash
arms
■ Revolving upper and lower rinse arms
■ Removable stainless steel scrap screen
■ Corrosion resistant pump
■ Automatic pumped drain
■ 17" door opening
■ Automatic ll
■ Detergent and rinse aid pumps standard
(plus sanitizer pump on chemical machine)
■ Electric tank heat
■ Two dishracks – one peg and one combination
type
STANDARD VOLTAGES
❑ 120/208-240(3W)/60/1 (LXeH model only)
❑ 120/60/1 (LXeC model only)
LXe HOT AND COLD
OPTIONS AT EXTRA COST
❑ 208-240(2W)/60/1 (LXeH model only)
❑ 208-240/60/3 (LXeH model only)
F40332 – LXe Hot and Cold Page 1 of 4

LXeH
HOT
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 2 of 4 F40332 – LXe Hot and Cold

LXeC
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
COLD
F40332 – LXe Hot and Cold Page 3 of 4

LXe
HOT AND COLD
SPECIFICATIONS
DESIGN: Front opening, equipped for installation in either
freestanding or undercounter-type operations.
CONSTRUCTION: 300 series stainless steel tank, door
and top panel.
PUMP: Centrifugal-type, integral with motor, horizontally
mounted. Pump capacity 38 gpm.
MOTOR: Single phase, furnished for all electrical specications. Factory sealed lubrication. Inherent overload
protection with auto reset.
WASH AND RINSE CYCLE: Complete automatic type,
controlled by solid-state electronics. Cycle may be interrupted any time by opening door. Cycle continues when
door is closed.
• Initial cycle lls wash tank, to be recirculated each wash
cycle. Some wash water is drained off before rinse
cycle. Rinse cycle refreshes wash water and tank heat.
RINSE PUMP: Powered by a single phase motor, the rinse
pump is made of high strength engineered composite
material.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
RINSE AND SANITATION:
• LXeH: Sanitation is accomplished by means of a built-in
booster heater designed to raise temperature of water
to a minimum of 180°F from an incoming water temperature of 110°F.
• LXeC: Sanitation is accomplished by injection of proper
amount of sodium hypochlorite solution (liquid bleach)
into nal rinse water to achieve a minimum of 50PPM
sanitizing solution. Injection of sodium hypochlorite is
accomplished by a built-in sanitizing chemical pump.
PUMPED DRAIN: Machine automatically drains water
through a built-in pump. Maximum 38" drain height
permitted.
RACKING: Machines accommodate racks from
10" x 20" to 20" x 20". Also accepts 16" x 18" cafeteria
trays.
NOTE: Certain materials, including silver, aluminum and
pewter are attacked by Sodium Hypochlorite solution in
the chemical sanitizing mode of operation.
SPECIFICATIONS: Listed by Underwriters Laboratories
Inc. and NSF International.
MACHINE RATINGS LXeC LXeH
Racks per Hour Rate 34 32
Dishes per Hour (25 per Rack Avg.) 850 800
Glasses per Hour (36 per Rack Avg.) 1224 115 2
Controls Microcomputer
Tank Capacity - Gallons 2.9
Overall Dimensions - H x W x D 321⁄2 " x 2315⁄16" x 259⁄16"
Cycle Time - Seconds 10 5 109
Tank H e a t 1.8 K W
Electric Booster Heater N/A 4.9 KW
Water Usage Per Rack - Gallons .74
Drain Design Pumped
Door Opening Height 17"
Detergent Pump Standard
Rinse-Aid Pump Standard
Sanitizer Pump Standard N/A
Chemical Prime (auto prime) Standard
Peak Drain Flow - GPM 4.0
Service Diagnostics Standard
70°Rise Sense-A-Temp™ Booster Heater N/A Standard
Incoming Water Temperature Required (minimum) 120° 110 °
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
Page 4 of 4 F40332 – LXe Hot and Cold