Hobart Food Machines FT1000S User Manual

Page 1
FT1000S ENERGY RECOVERY
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
WITH BLOWER DRYER
STANDARD FEATURES
Pumped rinse system (pressure gauge not required)
Water usage 58 gph
Digital controls with machine diagnostics
Low temperature alert
Single point vent location
31" access on prewash and power wash
chambers; 20" access on dual rinse and ASR chambers
Start and stop switches at both ends
Doors open indicator
Drains open indicator
Door interlocks
31⁄2 H.P. prewash, and 5 H.P. power wash pump
motors, all TEFC
Capless Auto Clean wash arms
Easy to remove stainless steel scrap pans and
baskets
30" wide conveyor belt
Dual Rinse
Automatic Soil Removal system (ASR)
Auto Clean
Auto Delime
Energy Recovery
Front and rear panels
Variable speed conveyor
MODEL
FT1000S Energy Recovery with Blower Dryer
Flight-Type Dishwasher
OPTIONS AT EXTRA COST
Electric Tank Heat
Steam Tank Heat
Booster Heater Electric Steam
Blower Dryer Electric Steam
6" higher than standard chamber
Multiple conveyor choices
Circuit breakers
Security package
Other options available, consult factory
ACCESSORIES
Flanged feet
Water hammer arrestor/PRV (installed by others)
Drain water tempering kit (installed by others)
Vent connection kit
Specications, Details and Dimensions on Inside and Back.
FT1000S ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER
DIRECTION OF OPERATION
Right to Left
Left to Right
• LA Research Report M660004
• Complies with EPA Reduction of Lead in Drinking Water Act 2014
• Meets requirements of ASSE Standard No. 1004
VOLTAGE
208/60/3
240/60/3
480/60/3
Other voltages available – consult factory
F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 1 of 12
Page 2
FT1000S ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
DESIGN: Fully automatic, ight-type dish machine consisting of a load section with Automatic Soil Removal system, power recirculating prewash, power wash and dual rinse/nal rinse section. Included with each machine will be exible plastic strip curtains to control overspray.
CONSTRUCTION: Stainless steel tank and chambers with No. 3 polish on appearance surfaces. Frame, legs and feet to be constructed of stainless steel. Inspection doors to be chamber width.
PUMPS: Recirculating stainless steel pumps with stainless steel impellers. Pump housing has easy to remove coverplate for access to impeller. Wash pumps are self-draining.
MOTORS: Totally enclosed fan cooled (TEFC) design with overload protection. Pump motors to be 31⁄2 H.P. for prewash, 5 H.P. for power wash, and conveyor motor to be 1⁄3 H.P. Available in electrical specica­tions of 208/60/3, 240/60/3 and 480/60/3.
CONTROLS: A stainless steel control center with electronic digital controls mounted at eye level. Power “On/Off” and “Start/Stop” switches integrated into keypad. Digital display indicates door(s) open, low temperature alert, tanks/nal rinse temperatures, Auto Clean and Auto Delime instructions and notica­tions, and other pertinent operating data. Additional “Start/Stop” switches are located at each end of machine. Conveyor speed button to be included on the control center to provide for the adjustable speed conveyor.
FLIGHT-TYPE CONVEYOR: Stainless steel side links, tie rods and conveyor tracks. Injection molded, resilient Duraex ight links.
VENT: Indirect vent connection with integral powered fan.
AUTOMATIC SOIL REMOVAL SYSTEM (ASR): Two foot section with specialized soil removal wash arms which removes food soil from the ware before it reaches the prewash tank. System will pump food soil from the ASR tank into an external collec­tor located under the load section, minimizing the need to pre-scrap dishes and reducing detergent consumption. Operator can easily remove and clean external collector without interruption of machine operation.
RECIRCULATING PREWASH SECTION: Prewash compartment is tted with upper and lower wash arms. Large removable one piece perforated stainless steel screen sloped downward to deep stainless steel scrap basket.
TANK HEAT: Power wash and dual rinse tank water temperatures are thermostatically controlled. Low water protection is provided. Specify either electric or steam heat.
FINAL RINSE: Easily removed nal rinse arms.
ENERGY RECOVERY: Energy Recovery system
operates with a cold water line, capturing energy from exhaust air, and using it to elevate the temperature of the water entering the booster heater. The result is savings – both in hot water and in energy.
CONVEYOR DRIVE UNIT: Powered by a 1⁄3 H.P. motor. Trip mechanism provided on unload section. Jam protection is provided by load sensing switch at drive platform. Conveyor speed adjustment of 4 feet per minute to 6.3 feet per minute is provided on the digital display keypad.
DRAINS: Manual, hand-operated, located at each tank. One manual and automatic master drain to be used for Auto Clean and Auto Delime.
BLOWER DRYER: Includes (2) 2 H.P. fan motors with sealed ball bearings and overload protection. Available in electric or steam heat.
Page 2 of 12 F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher
Page 3
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
FT1000S ENERGY RECOVERY
WITH BLOWER DRYER
No other control system allows easier monitoring.
The digital controls are placed in a convenient panel that lets operators verify proper operation and temperatures at a glance. Digital display indicates the unit is on, and conrms that the doors are closed. Automatic door interlocks prevent the pump and conveyor from operating if the doors are open. Easy-to-read digital display indicates accurate tem­peratures of the 160°F wash, 160°F dual rinse and 180°F nal rinse — critical for proper HACCP system record-keeping.
Stainless steel pump is built for long life.
The stainless steel pump housing and impeller offer greater durability and long life. The pump motor is totally enclosed and fan cooled (TEFC) to protect it from water spray during dishroom clean-up.
Scrap baskets capture food particles and are easy to clean.
The sloped screens that carry scraps to the scrap baskets are steeper, so less soil gets into the tanks. The basket opening is larger for easy cleaning and basket handles have been designed for easy lift-out access. The load section also features a removable scrap basket which contains soil that is pumped from the ASR section. All scrap baskets and strainers are stainless steel for strength and durability.
The FT1000 Series saves water and energy.
The unit has the lowest water and energy consumption in
the industry, yet provides effective cleaning and sanitizing that meets NSF International requirements.
This is achieved through a carefully balanced ratio of water ow to pressure. Insulated doors and thermal layered curtains also reduce heat loss. The unit’s 58 gallons per hour rinse ow rate saves both water and the energy to heat it.
Variable speed conveyor offers increased throughput.
The conveyor on the FT1000 Series is wider so it can handle more ware. Result: more volume and versatility, quicker work. Its speed is servicer adjustable for the type of ware, soiled condition, or workforce requirements. It runs at 4 - 6.3 feet per minute.
Energy Recovery system reclaims heat for energy.
The Energy Recovery system's heat exchanger captures escaping heat and steam from the exhaust air in the dish machine, and uses it to preheat the incoming cold water supply to 120°F before it enters the booster heater. In addition to energy savings, the Energy Recovery system provides a viable use for this otherwise exhausted heat.
Self-draining wash pumps help keep water clean.
Pumps are self-draining when the machine is shut down, so there is no residual water left in the pumps.
Installation is quick and easy with modular design, minimal wiring connections, and single point vent.
Modular design means the FT1000 installs quickly and reliably. The control panel is already in place, premounted to the dual rinse/nal rinse section.
Wiring connections are minimal, and there is only a single vent, saving time and expense. The control box uses a “single plane” circuitry design for easy accessibility during installation and service. The FT1000 is ready to run quickly.
F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 3 of 12
Page 4
FT1000S ENERGY RECOVERY
37 1/2"
63 3/8"
FLOOR LINE
7 7/8"3 15/16"
OVER FRAME "A"
62 3/4"
)
6" MINIMUM
ON THE TOP
FLOOR LINE
NOTE: REFER TO LATEST
NO
WITH BLOWER DRYER, ELECTRIC L-R
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
E1
E2
E3
E4
18 3/4"
E5
E6
E7
E8
P2
P1 P3
V1
P3
V1
E3
E7
5 3/4"
E2
E6
E1
5' 1"
9 15/16"
11 13/16"
25 9/16"
23 3/4"
6" AIR
GAP
25 9/16"
3"
P3
LOAD "B"
124 11/16"
E5
E4
E8
35 7/16" 35 7/16"
60"
52"
44 9/16"
UNLOAD "C"
EXHAUST HOOD SUPPLIED BY OTHERS
43 5/16"
P2 P1
23 3/4"
55 11/16"
V1
36 1/2"
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
BLOWER/
DRYER
AUX
LOAD
END
6"
35"
ASR
40 3/8"
44 13/16"
SEE NOTE (a)
PRE-
WASH
DIRECTION OF OPERATION
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
POWER
WASH
RNS
FNL RNS
MODEL NO.
FT1020S (7.5'-5'-7.5') 20' 4-1/16" FT1021S (8.5'-5'-7.5') 21' 3-13/16" FT1022S (9.5'-5'-7.5') 22' 3-21/32" FT1022S (7.5'-5'-9') 21' 11-13/16" FT1023S (8.5'-5'-9') 22' 11-9/16" FT1024S (9.5'-5'-9') 23' 11-13/32" FT1024S (7.5'-5'-11') 23' 11-7/16" FT1025S (8.5'-5'-11') 24' 11-3/16" FT1026S (9.5'-5'-11') 25' 11-1/32" FT1027S (7.5'-5'-15') 27' 6-3/4" FT1028S (8.5'-5'-15') 28' 6-1/2" FT1029S (9.5'-5'-15') 29' 6-11/32" FT1029S (7.5'-5'-17') 29' 6-5/16" FT1030S (8.5'-5'-17') 30' 6-1/16" FT1031S (9.5'-5'-17') 31' 5-29/32"
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"
UNLOAD
END
36 1/4"
"A""B"
7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32"
81 7/8"
89 3/8"
SEE NOTE (e
"C"
7' 6-1/2" 7' 6-1/2" 7' 6-1/2" 9' 2-1/4" 9' 2-1/4"
9' 2-1/4" 11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"
Page 4 of 12 F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher
Page 5
701 S Ridge Avenue, Troy, OH 45374
GENERAL NOTES:
(a)
A
Y INCREASE 3-1/4"
I
ELECTRICAL WARNING:
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
G (b)
(c)
HAN 55°F
(d)
WATER SUPPLY LINES AT SERVICE CONNECTION.
VENTILATION NOTES:
ELECTRICAL CONNECTIONS COMMON ON
E1
S
E2 ELECTRIC CONNECTION (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS W/O CIRCUIT BREAKERS:
E3
E4
E5 B
E6 1" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
BOOSTER
2" CONDUIT, 79-1/8" AFF
PLUMBING CONNECTIONS:
R
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
THERS).
95-3/8" AFF
MODEL: FT1000S ENERGY RECO
Y
ELECTRIC L-R OPER 00-949515 REV A1
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
SERVICE CONNECTION WITH CIRCUIT BREAKERS
SERVICE CONNECTION W/O CIRCUIT BREAKERS
480/60/3
40 40
26.8
ELECTRIC BOOSTER
MOTORS AND CONTROLS
1-888-4HOBART • www.hobartcorp.com
FT1000S ENERGY RECOVERY
WITH BLOWER DRYER,
ELECTRIC L-R
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, BOOSTER HEAT (TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3 WASH, DUAL RINSE HEAT, B/D HEAT & BLOWERS (TB2)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(4) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE 10KW,
BLOWER DRYER HEAT 7 KW & BLOWERS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
(1) 36 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
87.7
85.2
47.9
RATED
AMPS
164.1
155.6
78.3
RATED AMPS
56.1
52.4
ELECTRIC TANK HEAT, WASH
RATED AMPS
108.0 125 125
103.2 125 125
51.5 70 70
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
125 125
125 125
60 60
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200 200 200 200 100 100
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
70 70 70 70
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS
ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR
LL DIMENSIONS TAKEN FROM THE FLOOR LINE MA
WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL
WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION
NFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING
OF UNIT.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
ALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 40-45 PSI.
RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS T CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD
(e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS.
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDER (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
, VENT FAN CONTROL.
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208-240/60/3
480/60/3
F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 5 of 12
Drain and fill line configurations
RATED
AMPS
54.0 70 70
51.5 70 70
25.8 35 35
RATED
AMPS
33.7 45 45
22.1 30 30
y, safety and plumbing
CONDUCTOR
CONDUCTOR
MINIMUM
SUPPLY
AMPACITY
MINIMUM
SUPPLY
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
ELECTRIC CONNECTION, MOTORS & CONTROLS, 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TANK, 36KW. 1-1/4" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 10KW.
LOWER DRYER 7KW & BLOWER DRYER MOTORS.
1" CONDUIT. 79-1/8" AFF ELECTRIC CONNECTION, BOOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E7 ELECTRIC CONNECTION, M OTORS, CONTROLS, HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED). (TB1) 1-1/4" CONDUIT, 79-1/8" AFF
E8 ELECTRIC CONNECTION, WASH HEAT, DUAL RINSE HEAT, BLOWER DRYER HEAT & BLOWERS (TB2).
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATE MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM, 1" FPT, 5-1/2" AFF see notes (c) and (d).
P3 COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END OF UNIT, PLUG OPPOSITE END.
MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 750 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY O
BACK DRAFT PREVENTER REQUIRED (SUPPLIED AND INSTALLED BY OTHERS).
W/BLOWER DRYER
VER
ATION
Page 6
FT1000S ENERGY RECOVERY
62 3/4"
SEE NO
FLOOR LINE
7 7/8"
3 15/16"
OVER FRAME "A"
63 3/8"
6" MINIMUM
ON THE TOP
FLOOR LINE
NOTE: REFER TO LATEST
NO
WITH BLOWER DRYER, ELECTRIC R-L
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
55 11/16"
V1
P2
P1
23 3/4"
60"
52"
44 9/16"
UNLOAD "C"
SUPPLIED BY OTHERS
25 9/16"
EXHAUST HOOD
43 5/16"
23 3/4"
6" AIR
GAP
P2 P1
P3
11 13/16"
9 15/16"
V1
E2
E1
E6E7E8
5' 1"
5 3/4"
124 11/16"
E3
E4
18 3/4"
37 1/2"
V1 P3
E1
E5
E2
E6
E3
E7
E4
E8
P3
E5
LOAD "B"
35 7/16"35 7/16"
25 9/16"
3"
89 3/8"
TE (e)
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
81 7/8"
36 1/4"
35"
UNLOAD
END
40 3/8"
44 13/16"
SEE NOTE (a)
BLOWER/
DRYER
FNL RNS
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
POWER
AUX
WASH
RNS
DIRECTION OF OPERATION
MODEL NO.
FT1020S (7.5'-5'-7.5') 20' 4-1/16" FT1021S (8.5'-5'-7.5') 21' 3-13/16" FT1022S (9.5'-5'-7.5') 22' 3-21/32" FT1022S (7.5'-5'-9') 21' 11-13/16" FT1023S (8.5'-5'-9') 22' 11-9/16" FT1024S (9.5'-5'-9') 23' 11-13/32" FT1024S (7.5'-5'-11') 23' 11-7/16" FT1025S (8.5'-5'-11') 24' 11-3/16" FT1026S (9.5'-5'-11') 25' 11-1/32" FT1027S (7.5'-5'-15') 27' 6-3/4" FT1028S (8.5'-5'-15') 28' 6-1/2" FT1029S (9.5'-5'-15') 29' 6-11/32" FT1029S (7.5'-5'-17') 29' 6-5/16" FT1030S (8.5'-5'-17') 30' 6-1/16" FT1031S (9.5'-5'-17') 31' 5-29/32"
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"
PRE-
WASH
ASR
"A""B"
LOAD
END
7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32"
36 1/2"
6"
"C"
7' 6-1/2"
7' 6-1/2"
7' 6-1/2"
9' 2-1/4"
9' 2-1/4"
9' 2-1/4" 11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"
Page 6 of 12 F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher
Page 7
701 S Ridge Avenue, Troy, OH 45374
GENERAL NOTES:
(a)
A
Y INCREASE 3-1/4"
I
ELECTRICAL WARNING:
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
G (b)
(c)
HAN 55°F
(d)
WATER SUPPLY LINES AT SERVICE CONNECTION.
VENTILATION NOTES:
ELECTRICAL CONNECTIONS COMMON ON
E1
S
E2 ELECTRIC CONNECTION (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS W/O CIRCUIT BREAKERS:
E3
E4
E5 B
E6 1" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
BOOSTER
2" CONDUIT, 79-1/8" AFF
PLUMBING CONNECTIONS:
R
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
THERS).
95-3/8" AFF
MODEL: FT1000S ENERGY RECO
Y
ELECTRIC R-L OPER 00-949514 REV A1
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
SERVICE CONNECTION WITH CIRCUIT BREAKERS
SERVICE CONNECTION W/O CIRCUIT BREAKERS
480/60/3
40 40
26.8
ELECTRIC BOOSTER
MOTORS AND CONTROLS
480/60/3
1-888-4HOBART • www.hobartcorp.com
FT1000S ENERGY RECOVERY
WITH BLOWER DRYER,
ELECTRIC R-L
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, BOOSTER HEAT (TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3 WASH, DUAL RINSE HEAT, B/D HEAT & BLOWERS (TB2)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(4) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE 10KW,
BLOWER DRYER HEAT 7 KW & BLOWERS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
(1) 36 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
87.7
85.2
47.9
RATED
AMPS
164.1
155.6
78.3
RATED AMPS
56.1
52.4
ELECTRIC TANK HEAT, WASH
RATED AMPS
108.0 125 125
103.2 125 125
51.5 70 70
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
125 125 125 125
60 60
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200 200 200 200 100 100
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
70 70 70 70
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS
ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR
LL DIMENSIONS TAKEN FROM THE FLOOR LINE MA
WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL
WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION
NFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING
OF UNIT.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
ALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 40-45 PSI.
RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS T CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD
(e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS.
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDER (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
, VENT FAN CONTROL.
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208-240/60/3
F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 7 of 12
Drain and fill line configurations
RATED
AMPS
54.0 70 70
51.5 70 70
25.8 35 35
RATED
AMPS
33.7 45 45
22.1 30 30
y, safety and plumbing
CONDUCTOR
CONDUCTOR
MINIMUM
SUPPLY
AMPACITY
MINIMUM
SUPPLY
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
ELECTRIC CONNECTION, MOTORS & CONTROLS, 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TANK, 36KW. 1-1/4" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 10KW.
LOWER DRYER 7KW & BLOWER DRYER MOTORS.
1" CONDUIT. 79-1/8" AFF ELECTRIC CONNECTION, BOOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E7 ELECTRIC CONNECTION, M OTORS, CONTROLS, HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED). (TB1) 1-1/4" CONDUIT, 79-1/8" AFF
E8 ELECTRIC CONNECTION, WASH HEAT, DUAL RINSE HEAT, BLOWER DRYER HEAT & BLOWERS (TB2).
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATE MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM, 1" FPT, 5-1/2" AFF see notes (c) and (d).
P3 COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END OF UNIT, PLUG OPPOSITE END.
MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 750 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY O
BACK DRAFT PREVENTER REQUIRED (SUPPLIED AND INSTALLED BY OTHERS).
W/BLOWER DRYER
VER
ATION
Page 8
MODEL: FT1000S ENERGY RECO
STEAM L-R OPER 00-949515 REV A1
FT1000S ENERGY RECOVERY
FLOOR LINE
7 7/8"3 15/16"
OVER FRAME "A"
62 3/4"
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
63 3/8"
WITH BLOWER DRYER, STEAM L-R
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P7
15 11/16"
37 1/2"
E1
E2
E3
18 3/4"
V1
P3
P3
25 9/16"
3"
LOAD "B"
124 11/16"
35 7/16"
E3
P7
V1
E2
E1
35 7/16"
14 11/16"
P5
P6
2 15/16"
9 15/16"
11 13/16"
P8
28 7/16"
P4
5 3/4"
5 15/16"
33 3/8"
P7
38 1/4"
5' 1"
P1
P2
P3
P9
55 3/16"
51 15/16"
44 9/16"
33"
25 9/16" EXHAUST HOOD
SUPPLIED BY OTHERS
43 5/16" 23 3/4" 6" AIR
GAP
UNLOAD "C"
6 3/4"
P9
11 9/16"
21 3/4"
P6
23"
P5
23 1/8"
P1
P8
P2
23 3/4"
P4
28 15/16"
55 11/16"
V1
LOAD
END
36 1/2"
6"
Page 8 of 12 F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher
Drain and fill line configurations
y, safety and plumbing
ASR
PRE-
WASH
DIRECTION OF OPERATION
POWER
WASH
AUX RNS
FNL RNS
BLOWER/
DRYER
UNLOAD
END
SEE NOTE (f)
81 7/8"
36 1/4"
W/BLOWER DRYER
ATION
89 3/8"
VERY
Page 9
701 S Ridge Avenue, Troy, OH 45374
ELECTRICAL WARNING:
SERVICE WIRE TEMPERATURE RATING: 90C.
VENTILATION REQUIREMENTS:
V1
THERS).
95-3/8" AFF
NO
6" MINIMUM
ON THE TOP
FLOOR LINE
NOTE: REFER TO LATEST
GENERAL NOTES:
(a)
A
Y INCREASE 3-1/4"
I
PLUMBING NOTES:
G (b)
(c)
THE
(d)
(e) AT THE DISHWASHER, CONTACT SALES ENGINEERING.
VENTILATION NOTES:
(f)
ED
ELECTRICAL CONNECTIONS COMMON ON
E1
S
E2 ELECTRIC CONNECTION (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS WITH &
E3
,
1" CONDUIT. 79-1/8" AFF
PLUMBING CONNECTIONS:
)
(WHEN STEAM BOOSTER OPTION IS SPECIFIED)
3/4" FPT, 13" AFF
480/60/3
1-888-4HOBART • www.hobartcorp.com
FT1000S ENERGY RECOVERY
WITH BLOWER DRYER,
STEAM L-R
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
(1) SERVICE CONNECTION AS SHOWN BELOW
MOTORS AND CONTROLS
ELEC.
SPECS.
208-240/60/3
MODEL NO.
FT1020S (7.5'-5'-7.5') 20' 4-1/16" FT1021S (8.5'-5'-7.5') 21' 3-13/16" FT1022S (9.5'-5'-7.5') 22' 3-21/32" FT1022S (7.5'-5'-9') 21' 11-13/16" FT1023S (8.5'-5'-9') 22' 11-9/16" FT1024S (9.5'-5'-9') 23' 11-13/32" FT1024S (7.5'-5'-11') 23' 11-7/16" FT1025S (8.5'-5'-11') 24' 11-3/16" FT1026S (9.5'-5'-11') 25' 11-1/32" FT1027S (7.5'-5'-15') 27' 6-3/4" FT1028S (8.5'-5'-15') 28' 6-1/2" FT1029S (9.5'-5'-15') 29' 6-11/32" FT1029S (7.5'-5'-17') 29' 6-5/16" FT1030S (8.5'-5'-17') 30' 6-1/16" FT1031S (9.5'-5'-17') 31' 5-29/32"
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"
RATED
AMPS
40.5 60 60
26.4 35 35
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
"A""B"
7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32"
MAXIMUM
PROTECTIVE
DEVICE
"C"
7' 6-1/2" 7' 6-1/2" 7' 6-1/2" 9' 2-1/4" 9' 2-1/4"
9' 2-1/4" 11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"
THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING.
AFF = ABOVE FINISHED FLOOR
LL DIMENSIONS TAKEN FROM THE FLOOR LINE MA
WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL
WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION
NFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING
OF UNIT.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
ALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 40-45 PSI.
RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD WATER SUPPLY LINES AT SERVICE CONNECTION.
IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE
THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOV FROM THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS.
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 9 of 12
35"
MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 750 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY O
BACK DRAFT PREVENTER REQUIRED (SUPPLIED AND INSTALLED BY OTHERS).
40 3/8"
44 13/16"
SEE NOTE (a)
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDER (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
, VENT FAN CONTROL.
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATER MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM, 1" FPT, 5-1/2" AFF see notes (c) and (d).
P3 COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END OF UNIT, PLUG OPPOSITE END. 2" FPT. 7" AFF
P4 COMMON STEAM CONNECTION (TANK HEAT, STEAM BOOSTER &
BLOWER DRYER). 1-1/2" FPT, 4-3/8" AFF (10-45 PSI FLOWING PRESSURE see note (e).
P5 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P6 HOT WATER RELIEF VALVE, 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P7 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 2 CONNECTIONS. 3/4" FPT, 11" AFF
P8 CONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF
P9 CONDENSATE RETURN, GRAVITY CONNECTION (STEAM BLOWER DRYER), BUCKET TYPE TRAP FURNISHED.
Page 10
FT1000S ENERGY RECOVERY
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
MODEL: FT1000S ENERGY RECO
STEAM R-L OPER 00-949514 REV A1
62 3/4"
FLOOR LINE
7 7/8"
3 15/16"
OVER FRAME "A"
SEE NO
63 3/8"
WITH BLOWER DRYER, STEAM R-L
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
28 15/16"
55 11/16"
P4
V1
P2 P1
23 3/4"
P5
23 1/8"
23 1/16"
11 5/8"
P8
6 3/4"
60"
52"
44 9/16"
P6
P9
UNLOAD "C"
25 9/16"
EXHAUST HOOD
SUPPLIED BY OTHERS
43 5/16"
23 3/4"
6" AIR
GAP
P2
P1 P3
32 15/16"
14 5/8" 5 7/8"
11 13/16"
28 7/16"
38 1/4"
5' 1"
P5
P6
53 3/8"
22 5/8"
9 15/16"
P4
5 3/4"
P9
P7
P7
15 11/16"
18 3/4"
V1
124 11/16"
E3
E2
E1
P8
LOAD "B"
35 7/16"35 7/16"
P3
25 9/16"
3"
P7
37 1/2"
V1
P3
E1
E2
E3
89 3/8"
TE (f)
Page 10 of 12 F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher
81 7/8"
36 1/4"
y, safety and plumbing
Drain and fill line configurations
UNLOAD
END
BLOWER/
DRYER
FNL
RNS
AUX
POWER
RNS
WASH
DIRECTION OF OPERATION
PRE-
WASH
ASR
LOAD
END
36 1/2"
6"
W/BLOWER DRYER
ATION
VERY
Page 11
701 S Ridge Avenue, Troy, OH 45374
ELECTRICAL WARNING:
SERVICE WIRE TEMPERATURE RATING: 90C.
VENTILATION REQUIREMENTS:
V1
THERS).
95-3/8" AFF
NO
GENERAL NOTES:
(a)
A
Y INCREASE 3-1/4"
I
PLUMBING NOTES:
G (b)
(c)
THE
(d)
(e) AT THE DISHWASHER, CONTACT SALES ENGINEERING.
VENTILATION NOTES:
(f)
ED
ELECTRICAL CONNECTIONS COMMON ON
E1
S
E2 ELECTRIC CONNECTION (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS WITH &
E3
,
1" CONDUIT. 79-1/8" AFF
PLUMBING CONNECTIONS:
)
(WHEN STEAM BOOSTER OPTION IS SPECIFIED)
3/4" FPT, 13" AFF
6" MINIMUM
ON THE TOP
FLOOR LINE
NOTE: REFER TO LATEST
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
1-888-4HOBART • www.hobartcorp.com
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208-240/60/3
480/60/3
MOTORS AND CONTROLS
RATED
AMPS
40.5 60 60
26.4 35 35
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
FT1000S ENERGY RECOVERY
WITH BLOWER DRYER,
STEAM R-L
THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING.
AFF = ABOVE FINISHED FLOOR
MAXIMUM
PROTECTIVE
DEVICE
LL DIMENSIONS TAKEN FROM THE FLOOR LINE MA
WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL
WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION
NFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING
OF UNIT.
MODEL NO.
FT1020S (7.5'-5'-7.5') 20' 4-1/16" FT1021S (8.5'-5'-7.5') 21' 3-13/16" FT1022S (9.5'-5'-7.5') 22' 3-21/32" FT1022S (7.5'-5'-9') 21' 11-13/16" FT1023S (8.5'-5'-9') 22' 11-9/16" FT1024S (9.5'-5'-9') 23' 11-13/32" FT1024S (7.5'-5'-11') 23' 11-7/16" FT1025S (8.5'-5'-11') 24' 11-3/16" FT1026S (9.5'-5'-11') 25' 11-1/32" FT1027S (7.5'-5'-15') 27' 6-3/4" FT1028S (8.5'-5'-15') 28' 6-1/2" FT1029S (9.5'-5'-15') 29' 6-11/32" FT1029S (7.5'-5'-17') 29' 6-5/16" FT1030S (8.5'-5'-17') 30' 6-1/16" FT1031S (9.5'-5'-17') 31' 5-29/32"
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16"
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher Page 11 of 12
35"
MINIMUM OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 750 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY O
BACK DRAFT PREVENTER REQUIRED (SUPPLIED AND INSTALLED BY OTHERS).
"A""B"
40 3/8"
44 13/16"
SEE NOTE (a)
7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32" 7' 8-1/2" 8' 8-1/4" 9' 8-3/32"
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
7' 6-1/2"
7' 6-1/2"
7' 6-1/2"
9' 2-1/4"
9' 2-1/4"
9' 2-1/4" 11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
"C"
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
ALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 40-45 PSI.
RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO DISHWASHER IS 30-35 PSI. IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT AND COLD WATER SUPPLY LINES AT SERVICE CONNECTION.
IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE
THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOV FROM THE ENERGY RECOVERY UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS.
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDER (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
, VENT FAN CONTROL.
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110°F WATER MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION, 55°F WATER MINIMUM, 1" FPT, 5-1/2" AFF see notes (c) and (d).
P3 COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER END OF UNIT, PLUG OPPOSITE END. 2" FPT. 7" AFF
P4 COMMON STEAM CONNECTION (TANK HEAT, STEAM BOOSTER &
BLOWER DRYER). 1-1/2" FPT, 4-3/8" AFF (10-45 PSI FLOWING PRESSURE see note (e).
P5 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P6 HOT WATER RELIEF VALVE, 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P7 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 2 CONNECTIONS. 3/4" FPT, 11" AFF
P8 CONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF
P9 CONDENSATE RETURN, GRAVITY CONNECTION (STEAM BLOWER DRYER), BUCKET TYPE TRAP FURNISHED.
Page 12
FT1000S ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
FT (ight type) Models—many additional variations of these model specications are available. Engineering data furnished on request. Numbers in parentheses,
in feet of the following respectively; Loading section, Washing and Power Rinsing sections, Unloading section.
after model number from left to right, represent length
FT1000S Energy Recovery with Blower Dryer Series
(7.5, 9 Load / 5 Center / 7.5, 9, 11 Unload)
Machine Ratings (Mechanical)
Conveyor Speed — Feet per minute 4 - 6.3
Dishes per Hour 10,611
Motor — Horsepower ASR Soil - 1⁄4; ASR Wash - 1⁄3; Pre-Wash - 31⁄2; Wash - 5;
Tank Capacity — Gallons ASR - 7.2; Pre-Wash - 40; Wash - 40; Dual Rinse - 7.2
Rate of Final Rinse — Gallons per minute
(Pumped rinse) .97
Final Rinse Consumption — Gallons per hour (Pumped rinse) 58
Exhaust Requirements — Cubic feet per minute 750 (at standard air conditions)
Latent/Sensible Heat — BTU per hour Electric - Latent: 77,300 / Sensible: 33,100
Electric Heat Requirements
Tank Heat - Kilowatt (Regulated)
Optional Electric Booster - Kilowatt
Optional Blower Dryer - Kilowatt
Steam Heat Requirements
Steam Consumption
Tank Heat - Pounds per hour - maximum (Regulated) - based on 10 to 45 PSI steam at the machine
Optional Steam Booster - Pounds per hour - maximum
- based on 20 PSI steam, 110°F incoming water raised to 185°F (75°F rise) (180°F minimum)
Optional Steam Blower Dryer - Pounds per hour ­ maximum - based on 20 PSI steam
Peak Rate of Drain Flow — Gallons per minute Initial rate with full tanks 38
Shipping Weight Crated Varies by individual model - consult your Hobart representative
Dual Rinse - 1⁄6; Final Rinse - 1⁄2; Conveyor - 1⁄3; Blower Dryer (2) 2
Steam - Latent: 92,300 / Sensible: 39,600
Disconnect switches are recommended for each power circuit connected
to dishwasher. These disconnect switches are NOT furnished by Hobart
and should be installed by the electrical contractor at the time of installation.
Circuit breakers optional at extra cost.
Total tank heat - 43KW (Wash and Dual Rinse)
18KW - 110°F incoming water raised to 185°F (75°F rise) (180°F minimum)
7.0 KW
171 lbs./160°F Wash minimum - 160°F Dual Rinse minimum
42 lbs./180°F Final Rinse minimum
30 lbs.
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
Page 12 of 12 F40393 – FT1000S Energy Recovery with Blower Dryer Flight-Type Dishwasher
F40393 (REV. 09/14) LITHO IN U.S.A. (H-01)