Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
STEAM BOOSTER HEATER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
AM15
AM15T
AM15F
FLOWING
STEAM
PRESSURE
10 150 150 150 150 320
15 150 150 150 150 260
20 150 150 150 150 260
25 150 150 150 150 180
30 150 150 150 150 180
35 150 150 150 150 180
40 150 150 150 150 150
45 150 150 150 150 150
STEAM
CONSUMPTION
LB./HR.
STD. HEIGHT &
FLOWING
STEAM
PRESSURE
10 150 150 150 150 150 150
15 150 150 150 150 150 150
20 150 150 150 150 150 150
25 150 150 150 150 150 150
30 150 150 150 150 150 150
35 150 150 150 150 150 150
40 150 150 150 150 150 150
45 150 150 150 150 150 150
STEAM
CONSUMPTION
LB./HR.
BOOSTER
NO.
25 60 65 63 38
FT900
FT900S
6" HTS (132
GPH)
BOOSTER
NO.
77 66 70 52 42 49
STD. HEIGHT
(114 GPH)
BOOSTER
NO.
CL44e
CLPS66e
CLCS66e
BOOSTER
NO.
FT900S
6" HTS
(120 GPH)
BOOSTER
NO.
SIZES – ALL MODELS
CL54e
CLPS76e
CLCS76e
BOOSTER
NO.
FT900D
STD HEIGHT &
6" HTS (90 GPH)
BOOSTER
NO.
CL64e
CLPS86e
CLCS86e UW50
BOOSTER
NO.
FT900SD
STD. HEIGHT
(72 GPH)
BOOSTER
NO.
BOOSTER
NO.
STEAM BOOSTER HEATER SIZES – ALL MODELS
FT900SD
6" HTS
(84 GPH)
BOOSTER
NO.
Note 1 — Booster sizing based on 20 P.S.I. water ow pressure. Set pressure reducing valve under ow conditions.
Note 2 — All sizes based on 130°F minimum incoming water temperature raised to 185°F (55°F temperature rise).
Note 3 — Maximum steam pressure 45 P.S.I.
Order according to incoming steam pressure 10-20 P.S.I., 21-45 P.S.I. range.
Available electrical specications are 100-120/50/60/1 and 200-240/50/60/1.
Steam boosters require a separate service connection (AM and UW) rated at one of the above two available electrical
The steam booster is electrically controlled by means of a manual off-on switch, electric thermostat and solenoid valve.
Note 4 — Base FRC model requirements on basic “C” Line machines.
Note 5 — Indicate available owing steam pressure when ordering.
specications. Protection device rated at 15 amperes maximum (by others).
Included are line strainers and pressure relief valves on both steam and hot water lines, a hot water pressure regulator with
pressure gauge and a bucket type steam trap. When operated within the stated range of steam and water pressures the
recommended size booster will provide required quantities of nal rinse water with machine operating at maximum capacity.
F-40267 – Steam Booster Heater Sizes – All Models Page 1 of 2
STEAM BOOSTER HEATER
SIZES – ALL MODELS
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
STEAM BOOSTER HEATER SIZES #150/#180
⁄8
5
⁄16
3
⁄8 9
⁄16 12
7
5
A B
150 27
180 31
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
Page 2 of 2 F-40267 – Steam Booster Heater Sizes – All Models
F-40267 (10/09) LITHO IN U.S.A. (H-01)