HM Electronics BP200 Belt-pac Registration Instructions

Page 1
BP200
Belt-pac
REGISTRATION INSTRUCTIONS
Prior to operation of the DX200 system, each Belt-pac must be registered for use with a specific base station. The base station will then recognize all registered Belt-pacs when their power is on, differentiating between them and interfering transmissions from other electronic equipment operating on similar frequencies. If a Belt-pac is added or replaced later, the new one must be registered. When a Belt-pac is replaced, the old one remains in memory. A maximum of 15 Belt­pacs can be registered to a single base station. If the maximum number of 15 (in memory) is exceeded, an F will appear in the REGISTRATION STATUS display on the base station and you will hear “Registration failed” in the headset. If this happens, refer to the last section on the back of this sheet.
Register each Belt-pac as follows:
NOTE: Belt-pacs must be within 6 feet (1.83 meters) of the base station while being registered.
Be certain all Belt-pacs to be registered are powered off and the base station power is on.
Other Belt-pacs can be on or off.
Press the REGISTER BELT-PAC button shown in Figure 1.
After you press the REGISTER BELT-PAC button, the REGISTRATION STATUS display will show a small “o” for open.
NOTE: To press the
RESET button, insert a small paper clip or similar object into the RESET
HM ELECTRONICS, INC.
Figure 1. Registration buttons and indicat or on left front panel of base stat ion
14110 Stowe Drive, Poway, CA 92064 USA Phone: 1-800-848-4468 Fax: (858) 552-0172
HME# 400544 Rev— 3/2/04
Page 2
Press and hold the ISO button on the Belt-pac while pressing and releasing the PWR (power) button to turn the unit on, then release the ISO button. This will cause the Belt-pac to enter the registration mode. The two power lights next to the IC and ISO buttons on the Belt-pac will begin blinking red, then will blink green two or three times and go off momentarily.
Wait! There may be a short delay. One of the following will happen.
If Registration is Successfully Completed: If Registration Failed:
A voice message in the headset will say “Power on, Belt-pac #, Version #, Begin registration, Registration complete, …” After a delay of up to 15 seconds (in some cases), the REGISTRATION STATUS disp lay will show the ID number assigned to this Belt-pac, momentarily. NOTE: ID numbers are assigned sequentially as 0 thru 9, A, b, C, d and E. The power light on the Belt-pac, next to the IC button, will remain on steady green.
A voice message in the headset will say “Power on, Belt-pac #, Ver s ion #, Begin registration, …” Both power l ights on the Be lt-p a c will be blinking red, and there may be a delay of up to 90 seconds before yo u hear “Registration failed.”
If the failure is due to excessive (more than 15) Belt-pacs registered, an F will also appear on the REGISTRATION STATUS display. If this happens, follow the instructions at the bottom of this page.
Press the RESET button. (See Figure 1.) When the REGISTRATION STATUS display
goes blank, press the REGISTER BELT-PAC button and repeat the registration procedure. If registration fails again, call (in the USA) HME Customer Support at 1-800-848-4468 or (outside the USA) your local HME representative for assistance.
“ISO”
button
“IC”
button
Power button
Figure 2. Registration controls on Belt-pac
When the maximum number of Belt-pacs (15) is exceeded:
If a Belt-pac is replaced, the new one must be registered and the old one remains in memory. If the maximum number of 15 (in memory) is exceeded, all current registrations must be cleared and all active Belt-pacs must be re-registered. To clear all current registrations, press the RESET REGISTRATION button and the RESET button simultaneously. To press the RESET button, insert a small paper clip or similar object into the RESET hole at the lower-left corner of the base station front panel. Refer to Figure 1. Continue holding the RESET REGISTRATION button after releasing the RESET button, until the clear code “c” (lower case) appears momentarily on the REGISTRATION STATUS display. All active Belt-pacs can then be registered, one at a time. (Previously registered Belt-pacs must be re-registered.)
Loading...