Technical Data Sheet
LOCTITE®7471™
February-2008
PRODUCT DESCRIPTION
LOCTITE®7471™ provides the following product characteristics:
Technology
Activator for LOCTITE® anaerobic
adhesives and sealants Chemical Type Amine and Thiazole Solvent Acetone and Isopropanol Appearance Transparent, yellow to amber liquid
LMS
Viscosity Very low
Cure Not applicable Application Cure acceleration of
LOCTITE® anaerobic products
LOCTITE®7471™ is used where increased cure speed of LOCTITE® anaerobic products is required. It is especially recommended for applications with passive metals or inert surfaces and with large bond gaps. LOCTITE®7471™ is particularly recommended when prevailing temperature is low (<15 °C).
TYPICAL PROPERTIES
Specific Gravity @ 25 °C 0.79 Viscosity @ 20 °C, mPa·s (cP) 2 Drying Time @ 20 °C, seconds 30 to 70 On Part Life, days ≤7 Infrared Spectrum To match standard
LMS
Flash Point - See MSDS
TYPICAL PERFORMANCE
Fixture time and cure speed achieved as a result of using LOCTITE®7471™ depend on the adhesive used and the substrate bonded.
Fixture Time, ISO 4587, minutes:
Zinc dichromate using LOCTITE® 640™, two side activation
≤25
(Fixture time is defined as the time to develop a shear strength of 0.1 N/mm²)
TYPICAL PERFORMANCE OF CURED MATERIAL
Adhesive Properties
After 5 minutes @ 25 °C
Compressive Shear Strength, ISO 10123:
Steel pins and collars (degreased), using LOCTITE®640™
N/mm² ≥4.5
LMS
(psi) (≥2,935)
Handling precautions
Activator must be handled in a manner applicable to highly flammable materials and in compliance with relevant local regulations.
The solvent can affect certain plastics or coatings. It is recommended to check all surfaces for compatibility before use.
GENERAL INFORMATION This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected with a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the Material Safety Data Sheet (MSDS).
Under no circumstances should activator and adhesive be mixed directly as liquids.
Use only in a well ventilated area
Where aqueous washing systems are used to clean the surfaces before bonding, it is important to check for compatibility of the washing solution with the adhesive. In some cases these aqueous washes can affect the cure and performance of the adhesive.
Directions for use
1. Spray or brush on the activator on both mating surfaces to be bonded. For small gaps, treatment of only one surface may be adequate. Contaminated surfaces may need repeated treatment or special degreasing prior to activation to remove any dissolvable contamination. Porous surfaces may need two treatments of activator.
2. Allow the solvent time to evaporate under good ventilation until the surfaces are completely dry.
3. After activation, parts should be bonded within 7- days. Contamination of the surface before bonding should be prevented.
4. Apply the Loctite Anaerobic product to one or both surfaces and assemble parts immediately.
5. Where possible, move surfaces in relation to each other for a few seconds on assembly to properly distribute the adhesive and for maximum activation..
6. Secure the assembly and await fixturing before any further handling..
Loctite Material Specification
LMS
LMS dated September-01, 1995. Test reports for each batch are available for the indicated properties. LMS test reports include selected QC test parameters considered appropriate to specifications for customer use. Additionally, comprehensive controls are in place to assure product quality and consistency. Special customer specification requirements may be coordinated through Henkel Quality.
Documentation Provided By HMC Electronics
33 Springdale Ave. Canton, MA 02021
http://www.hmcelectronics.com
(800) 482-4440
TDS LOCTITE®7471™, February-2008
Storage
This activator is classified as HIGHLY FLAMMABLE and must be stored in an appropriate manner in compliance with relevant regulations. Do not store near oxidising agents or combustible materials. The product is light sensitve and accordingly, translucent containers should be kept in a dark place when not in use. Store product in the unopened container in a dry location. Storage information may also be indicated on the product container labelling.
Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or greater than 28 °C can adversely affect product properties.
Material removed from containers may be contaminated during use. Do not return product to the original container. Henkel cannot assume responsibility for product which has been contaminated or stored under conditions other than those previously indicated. If additional information is required, please contact your local Technical Service Center or Customer Service Representative.
Conversions
(°C x 1.8) + 32 = °F kV/mm x 25.4 = V/mil mm / 25.4 = inches µm / 25.4 = mil N x 0.225 = lb N/mm x 5.71 = lb/in N/mm² x 145 = psi MPa x 145 = psi N·m x 8.851 = lb·in N·m x 0.738 = lb·ft N·mm x 0.142 = oz·in mPa·s = cP
Note
The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained by others over whose methods we have no control. It is the user's responsibility to determine suitability for the user's purpose of any production methods mentioned herein and to adopt such precautions as may be advisable for the protection of property and of persons against any hazards that may be involved in the handling and use thereof. In light of the foregoing, Henkel Corporation
specifically disclaims all warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose, arising from sale or use of Henkel Corporation’s products. Henkel Corporation specifically disclaims any liability for consequential or incidental damages of any kind, including lost profits. The discussion
herein of various processes or compositions is not to be interpreted as representation that they are free from domination of patents owned by others or as a license under any Henkel Corporation patents that may cover such processes or compositions. We recommend that each prospective user test his proposed application before repetitive use, using this data as a guide. This product may be covered by one or more United States or foreign patents or patent applications.
Trademark usage
Except as otherwise noted, all trademarks in this document are trademarks of Henkel Corporation in the U.S. and elsewhere. ® denotes a trademark registered in the U.S. Patent and Trademark Office.
Reference 1.1
Henkel Americas +860.571.5100
Henkel Europe
+49.89.320800.1800
Henkel Asia Pacific
+86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial