LOCTITE® 444™
March-2010
PRODUCT DESCRIPTION
LOCTITE® 444™ provides the following product characteristics:
Technology Cyanoacrylate Chemical Type Ethyl cyanoacrylate Appearance Colorless transparent liquid
LMS
Components One part - requires no mixing Viscosity Medium
Cure Humidity Application Bonding
Key Substrates Rubbers, Plastics and Metals
LOCTITE® 444™ is a single part, fast curing medium viscosity cyanoacrylate adhesive formulated for electronics applications. LOCTITE® 444™ is designed to use with TAK PAK® Accelerators to attain instant cures for tacking electronics components . Typical applications include wire tacking to coil forms; tamper proofing adjustable components; mounting standoffs, edge guides and stiffeners to circuit boards.
Commercial Item Description A-A-3097:
LOCTITE® 444™ has been qualified to Commercial Item Description A-A-3097. Note: This is a regional approval. Please contact your local Technical Service Center for more information and clarification.
TYPICAL PROPERTIES OF UNCURED MATERIAL
Specific Gravity @ 25 °C 1.05 Viscosity, Brookfield - LVF, 25 °C, mPa·s (cP):
Spindle 2, speed 30 rpm 550 to 850
LMS
Flash Point - See MSDS
TYPICAL CURING PERFORMANCE
Under normal conditions, the atmospheric moisture initiates the curing process. Although full functional strength is developed in a relatively short time, curing continues for at least 24 hours before full chemical/solvent resistance is developed.
Cure Speed vs. Bond Gap
The rate of cure will depend on the bondline gap. Thin bond lines result in high cure speeds, increasing the bond gap will decrease the rate of cure.
Cure Speed vs. Activator
Where cure speed is unacceptably long due to large gaps, applying activator to the surface will improve cure speed. However, this can reduce ultimate strength of the bond and therefore testing is recommended to confirm effect.
TYPICAL PROPERTIES OF CURED MATERIAL
After 24 hours @ 22 °C
Physical Properties:
Coefficient of Thermal Expansion, ISO 11359-2, K
-1
80×10
-5
Coefficient of Thermal Conductivity, ISO 8302, W/(m·K)
0.11
Glass Transition Temperature, ASTM E 228, °C
130
Electrical Properties:
Volume Resistivity, IEC 60093, Ω·cm
7.2×10
15
Surface Resistivity, IEC 60093,Ω66×10
15
Dielectric Breakdown Strength, IEC 60243-1, kV/mm
36.6
Dielectric Constant / Dissipation Factor, IEC 60250:
1-kHz 3.0 / 0.028
TYPICAL PERFORMANCE OF CURED MATERIAL
Cured for 2 minutes @ 22 °C
Lap Shear Strength, ISO 4587:
Steel (grit blasted) N/mm² ≥5.4
LMS
(psi) (≥780)
GENERAL INFORMATION This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as a sealant for chlorine or other strong oxidizing materials
For safe handling information on this product, consult the Material Safety Data Sheet (MSDS).
Directions for use:
1.
Apply one coating of TAK PAK® accelerator to the area to be bonded, by spray, brush or dipping. Prior to application, contaminated surfaces may need special cleaning or degreasing to remove any dissolvable contamination.
NOTE: Because the solvent base of TAK PAK® accelerators can affect certain plastics or coatings, checking all surfaces for compatibility is recommended.
.
2. Allow the accelerator time to evaporate under good ventilation until the surfaces are completely dry (approx. 15 to 30- seconds)..
Documentation Provided By HMC Electronics
33 Springdale Ave. Canton, MA 02021
http://www.hmcelectronics.com
(800) 482-4440
TDS LOCTITE® 444™, March-2010
3.
Apply LOCTITE® 444™ cyanoacrylate product immediately after solvent has dried.
NOTE: If cyanoacrylate is not applied to the accelerator within 45 seconds, accelerator should be reapplied
.
4. Where possible, move surfaces in relation to each other for a few seconds on assembly to properly distribute the adhesive and for maximum activation..
5. Secure the assembly and await fixturing before any further handling..
Loctite Material Specification
LMS
LMS dated December-28, 1999. Test reports for each batch are available for the indicated properties. LMS test reports include selected QC test parameters considered appropriate to specifications for customer use. Additionally, comprehensive controls are in place to assure product quality and consistency. Special customer specification requirements may be coordinated through Henkel Quality.
Storage
Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling.
Optimal Storage: 2 °C to 8 °C. Storage below 2 °C or greater than 8 °C can adversely affect product properties.
Material removed from containers may be contaminated during use. Do not return product to the original container. Henkel Corporation cannot assume responsibility for product which has been contaminated or stored under conditions other than those previously indicated. If additional information is required, please contact your local Technical Service Center or Customer Service Representative.
Conversions
(°C x 1.8) + 32 = °F kV/mm x 25.4 = V/mil mm / 25.4 = inches µm / 25.4 = mil N x 0.225 = lb N/mm x 5.71 = lb/in N/mm² x 145 = psi MPa x 145 = psi N·m x 8.851 = lb·in N·m x 0.738 = lb·ft N·mm x 0.142 = oz·in mPa·s = cP
Note
The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained by others over whose methods we have no control. It is the user's responsibility to determine suitability for the user's purpose of any production methods mentioned herein and to adopt such precautions as may be advisable for the protection of property and of persons against any hazards that may be involved in the handling and use thereof. In light of the foregoing, Henkel Corporation
specifically disclaims all warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose, arising from sale or use of Henkel Corporation’s products. Henkel Corporation specifically disclaims any liability for consequential or incidental damages of any kind, including lost profits. The discussion
herein of various processes or compositions is not to be interpreted as representation that they are free from domination of patents owned by others or as a license under any Henkel Corporation patents that may cover such processes or compositions. We recommend that each prospective user test his proposed application before repetitive use, using this data as a guide. This product may be covered by one or more United States or foreign patents or patent applications.
Trademark usage
Except as otherwise noted, all trademarks in this document are trademarks of Henkel Corporation in the U.S. and elsewhere. ® denotes a trademark registered in the U.S. Patent and Trademark Office.
Reference 1.3
Henkel Americas +860.571.5100
Henkel Europe
+49.89.320800.1800
Henkel Asia Pacific
+86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial
Documentation Provided By HMC Electronics
33 Springdale Ave. Canton, MA 02021
http://www.hmcelectronics.com
(800) 482-4440
Loading...