Hitron TECHNOLOGIES XM2 User Manual

WIRELESS DOCSIS 3.1 METER
DOCSIS 3.1 meter using Intel® Puma™ 7 OFDM 2x2 with 2x2 5GHz and 2x2 2.4GHz dual band Wi-Fi, LTE, GigE and USB ports
KEY FEATURES
XM2
DOCSIS 3.1/3.0/2.0/1.1 compliant
Wi-Fi 2x2 5GHz 802.11ac and 2x2 2.4GHz
802.11n dual band internal antennas
Wireless connection with smartphone to initiate tests and display results
Smartphone App support (IOS / Android)
1 x RJ-45 Ethernet port 10/100/1000Mbps
Two USB 2.0 ports (5V/1A)
LTE detection
Battery 9000mAh
2 RF connectors (outside & home)
FAN cooling
AC detection
Full frequency spectrum support
IQ constellation
Pre-equalizer analysis
Switchable Upstream 5-85/5-42
QAM measurements
Channel plan scan
Ping and trace route
Channel plan
System information
DOCSIS WAN
DOCSIS logger
DOCSIS provisioning status
MoCA power spectrum display
Downstream OFDM/OFDMA Metrics
Fast reposting available QAM channel
Wi-Fi scan capability including channel utilization
statistics to replace Raspberry Pi
Speed test (iperf 3, ariac2)
Buffers for persistence mode analysis
Firmware & APK Upgrade
Empower technicians to troubleshoot the whole home
XM2 is a powerful troubleshooting tool offering the major tests required to measure both DOCSIS and DVB-C networking environments. Through MSO partnerships, this wireless DOCSIS 3.1 meter was specially tailored to the requirements faced by installers and service technicians in the field.
The XM2 is a cable/DVB-C probe with 1 Gigabit Ethernet port and 802.11b/g/n/ac wireless LAN Access Point combined into one device to simplify cable connectivity testing and troubleshooting. The unit contains a DOCSIS 3.1/3.0/2.0/1.1 compliant cable modem to insure interoperability with existing cable systems. Through the use of technicians’ smartphones and our specifically-designed app (iOS & Android), Hitron aims to offer the most cost-efficient testing solution containing the major features MSOs require.
The XM2 also features a speed test function for proofing the customer’s premise as well as the outside network. It enables customizable DOCSIS logging functions that allow increased visibility and details.
Hitron HQ - www.hitrontech.com
No. 1-8, Lihsin 1st Rd, Hsinchu Science Park
Hsinchu, Taiwan
Tel: +886 3 5786658
USA - www.hitron-americas.com
9000 E Nichols Ave
Centennial CO 80112 Suite 103
Tel: +1 303 792 3380
Kingsfordweg 151 1043 GR
Amsterdam, The Netherlands
Tel: +31 20 491 9995
SPECIFICATIONS
XM2
Connectivity
2 x RF F-type male 75Ω connector
LTE antenna 700 MHz ~ 1.8GHz
1 x RJ-45 Ethernet port 10/100/1000 Mbps (Auto-
MDI/MDIX)
2 x USB2.0 (5V, 1A)
Management
App-based GUI for configuration and management
Protocol support: SNMP v1, v2C, v3
Power on self diagnostic
MIB II/MCNS MIB
Hitron proprietary MIBs for extended support
Reception-Demodulation
DOCSIS 3.1/3.0/2.0 /1.1
DOCSIS 3.1 demodulation: Multi-carrier OFDM 16
to 4096QAM
DOCSIS 3.1 data rate: Up to 5Gps with 2 OFDM 192MHz downstream channels +32 QAM
DOCSIS 3.0 demodulation: 64QAM, 256QAM
DOCSIS 3.0 data rate: Up to 1.2Gbps with 32
bonded downstream channels
Frequency (edge-to-edge): 108~1218MHZ/54~1218MHz (EuroDOCSIS/DOCSIS)
1350~1675MHZ(MoCA2.0)
Channel bandwidth: 6/8 MHz (DOCSIS 3.0)
100Mhz (MoCA2.0)
Signal level: -15dBmV to 15dBmV
Input return loss: >6dB
Transmitter-Modulation
DOCSIS 3.1/3.0/2.0 /1.1
DPCSOS 3.1 modulation: Multi-carrier OFDMA
96MHz US channels
DOCSIS 3.0 modulation: QPSK, 8QAM, 16QAM, 32QAM, 64QAM, and 128QAM (SCDMA only)
DOCSIS 3.0 data rate: Up to 320Mbps with 8 bonded upstream channels
Frequency: switchable 5-85/5-42MHz
1350~1675Mhz(MoCA2.0)
Upstream transmit signal level: +11 to 65dBmV
Output return loss: >6dB
Wireless
Dual band Wi-Fi
802.11a/b/g/n/ac
2T2R 5GHz (5180MHz-5240MHz band 1, 5748-5825MHz
band 4) 802.11ac with 400Mbps PHY data rate
2T2R 2.4GHz (2412MHz-2462MHz) 802.11n with 150Mbps PHY data rate
20/40MHz channel bandwidth
Up to 4 SSIDs for each frequency
Security: WPS, WPA, WPA2, WPA-PSK and 64/128- bit
WEP encryption
Wi-Fi output power Range :
Mechanical
7 status LEDs (Power, Wi-Fi, DS, US, Status, Charge, Bat)
Factory reset button
Power restart button
Dimensions: 165mm (W) x 210mm (H) x 79mm (D)
Weight: 1100g ± 10g
Electrical
Power adaptor: 100-240VAC to 12VDC, 50/60Hz, 5A
Power input: 12VDC
Power consumption: 32W (typical), 48W (max)
Battery: lithium battery cells 9000mAh
(8h of typical operation, 4.5h full load, 4h to charge)
Surge protection: RF input sustains at least 4KV,
Ethernet RJ-45 sustains at least 4KV
Environmental
Operating temperature: 0°C (32°F) - 40°C (104°F)
Operating humidity: 10% - 90% (non-condensing)
Storage temperature: -40°C (-40°F) - 80°C (176°F)
Compliance Certificates
FCC, IC, UL
RoHS compliant
IP20
XM2_2018_1A - Issued Apr 2018
Specifications subject to change without further notice
Trademarks owned by Hitron Technologies Inc. 2018 © Hitron Technologies Inc. – All rights reserved
Federal Communication Commission Interference
Statement
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 25 cm between the radiator & your body.
Industry Canada statement:
This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable.
Caution :
(i) the device for operation in the band 5150-5250 MHz is only
for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
(iii) where applicable, antenna type(s), antenna models(s), and worst-case tilt angle(s) necessary to remain compliant with the e.i.r.p. elevation mask requirement set forth in section 6.2.2.3 shall be clearly indicated.
Avertissement:
(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz
sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux;
(iii) lorsqu’il y a lieu, les types d’antennes (s’il y en a plusieurs), les numéros de modèle de l’antenne et les pires angles d’inclinaison nécessaires pour rester conforme à l’exigence de la p.i.r.e. applicable au masque d’élévation, énoncée à la section 6.2.2.3, doivent être clairement indiqués.
Radiation Exposure Statement:
This equipment complies with ISED radiation exposure
limits set forth for an uncontrolled environment. This equipment should be installed and operated with greater than 30 cm between the radiator & your body.
Déclaration d'exposition aux radiations:
Cet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé à plus de 30 cm entre le radiateur et votre corps.
Specifications subject to change without further notice
Trademarks owned by Hitron Technologies Inc. 2018 © Hitron Technologies Inc. – All rights reserved