User’s manual for GSM+PSTN Touch Screen Wireless Alarm System
I. Foreword
Thank you for purchasing and using GSM/PSTN LCD touch screen wireless home alarm system. This is a Hi-tech
household security product. It will make your life safer and colorful.
Please read the below information carefully before using for a proper usage.
II. Brief introduction of the Product
A. Product components: This product is composed of alarm host, basic accessories and optional accessories.
Wireless Optional Accessories
remote, wireless intelligent door sensor(or wireless door
sensor) wireless wide-angle PIR sensor, , wireless indoor siren
with sound and flash
gas alarm, smoke alarm,
wireless keypad, wireless
outdoor siren, doorbell button
Table 1: Product components
III. Function Features
1. Touch keypad; LCD displays Date, Day of the week, Time, and current Armed Status
2. Supported Languages: Simplified Chinese\ Traditional Chinese\ English\ German\ French\ and more to meet different
market needs..
3. 2 /4 Band GSM/PSTN dual net-work. Support phone call alarm and SMS alarm, automatically switch to GSM dailing
when telephone line is cut.
4. 29 wireless zones (Each zone supports up to 4 sensors) and 2 dedicated zones for remotes (Supports up to 4 remotes
or wireless keypads per zone). Sipports 8 more wired zones(Optional).
5. Can preset up to 5 phone numbers and dial in sequence.
6. Intelligent logic analysis technology, corresponding zone number and sensor name can be displayed.
7. Record up to a 10 second greeting for the auto-dialer, Then play the greeting back.
8. Arm\ Disarm the system by 5 ways: SMS, Main Host(Keypad), Wireless Keypad, Keychain Remotes, or even remotely
by phones. (PSTN alarm don‟t support SMS)
9. Available in AC\DC with Low-voltage Indicators
10. Learning sensors to alarm host, very easy operation.
11. Non-volatile chip, information stored automatically when off power.
12. Check door\window status automatically (This is when the system is disarmed only, if a door is opened, it will sound fast
“bi bi bi”)
13. Support wireless “ding-dong” doorbell function (Optional)
14. Support CID uploading to CMS(Center monitoring Station) , can user our GSM CID connector to have this function.
15. Disconnection alarm, auto priority to occupy the telephone and monitoring function to hear what is happening.
16. Built-in Li-Ion backup battery, it will alert when low power or without external power supply.
17. Store up to 100 alarm records and 100 arm\disarm records
IV. Understanding of the Products
A. Understanding of the Alarm Host
![](/html/bf/bf4d/bf4d7982f612339fdb718762b4fcd8f80557350ce5047f7dba1364fda96e75b7/bg2.png)
/
Power /Signal
Low voltage
Status indicator
Emergency/Back Space
Number/Arm
Disarm/Delete/Esc
Confirm
Mic
Program
PgUp & PgDn
08.08 6
12 26 28
Connect antenna here
Speaker
Backup battery ON/OFF
Power
Extend 8 wired zones here (Optional)
ON
OFF
IN
TEL
OUT
Tel out
Tel in
()
Connect wired siren here
Optional
Record
Play
SIM
SIM card slot
Back Side
1. Specifications:
Working power: AC=100~230V, DC=12V 1A
Static current:<50mA (when not charging) Alarm current:<500mA
Built-in Li-Ion backup battery: 3.7V 800mAH(rechargeable),
Standby: around 16 hours, Full charging time: 12 hours
2-Band GSM: GSM900/1800Mhz(4-Band is optional: 850/900/1800/1900Mhz)
GSM transmit power: 2W
Receiving and emitting frequency: 433MHz
Working condition:
Temperature: -10ºC ~ 50ºC Humidity: <80%
Product dimension:150×107×26(mm)
2. Zone types and definitions
Zone types: Perimeter zone, Motion zone, Emergency zone
Definitions:
Perimeter zone: Detecting the space like doors, windows, etc., generally use wireless door magnet sensors and wireless
curtain PIR sensors
Motion zone: Detecting the space like living room, aisles and bedrooms, etc., generally use wireless wide-angle PIR sensors.
![](/html/bf/bf4d/bf4d7982f612339fdb718762b4fcd8f80557350ce5047f7dba1364fda96e75b7/bg3.png)
Emergency zone: Detecting the space like Emergency area (such as emergency distress, medical rescue, gas leakage and
fire alarm, etc., this zone keep 24-hour monitoring status automatically. Generally use panic button, wireless gas sensors and
wireless smoke sensors.
3. Modes of arming
“Away Arm” mode:Once any detectors in perimeter zones or motion zones get triggered, the host will alarm immediately and
meantime dial “#” automatically.
“Home Arm” mode:Once any detectors in perimeter zones get triggered, the host will alarm immediately and meantime dial “#”
automatically. It will not alarm after any detectors in the motion zone are triggered.
4. How to operate the alarm host
Preparation
1. Insert SIM card properly.
2. Fix the antenna
3. Connect the telephone cable: connect the telephone cable of telecommunication to “Tel in” port on the alarm host, then
use the telephone cable attached in the package to connect “Tel out” port and telephone set.
4. Connect power: connect the power adaptor to DC port of the alarm host first, then plug it to the AC socket.
5. Turn on the backup battery
6. Check and see if GSM signal is good enough
Signal is not normal or SIM card not
inserted properly
Signal indicator keeps flash about
every 2 seconds
Signal indicator keeps on
4-Band
(850/900/1800/900 MHZ)
Signal indicator keeps flash about
every 3 seconds
Signal indicator keeps flash about
every 1 seconds
Signal level status
When standby, press“▲”or“▼”and you can see the signal status as below.
XX: 0 …..31 indicates the signal from weak to strong,99 indicates unknown.
YY: Indicates signal status, OK is good, No is a little weak and need to adjust installation position.
Press “ESC” to get back for standby status. Or get back to standby status automatically after 30 seconds without no operation.
Note: If SIM card is not insert properly, it will shows:
How to program
Notes:
The host will exit programming mode if without any operation within 30 seconds
It will exit to the previous menu if press “ESC”
If enter codes by mistake for 3 times, the host panel will resume to the standby mode
you can press “▲▼” to adjust programming info. Or to find alarming info.
1. Menu preview
Call by phone
SMS reportng
Alarming phone number,
Group 2~5 for personal
Duration time
of alarming sound
![](/html/bf/bf4d/bf4d7982f612339fdb718762b4fcd8f80557350ce5047f7dba1364fda96e75b7/bg4.png)
No need to setup
for personal use
No need to setup
for personal use
No need to setup
for personal use
Needed when adding
wireless sensors
Detect and indicate
open/close states of
doors/windows
ActivateSensor
Delete Sensor
For Adding or
deleting wireless sensor
Usually no need for users
For checking
alarming history records.
For checking
working records
Table 2: Menu Preview
2. Detailed program instructions:
For any program, you should start with【SET + Enter code + input the 6-digit code (default: 888888)+ENT】
【Set time】:
【ENT + press “ ” to delete the old record + input current time+ENT】→ “X X X X X X”: 6 digits, means “hour, minute, second”,
each takes 2 digits space, e.g. you may press 142120, now the host time will be 14:21:20.
【Set date】:
【ENT + press “ ” to delete the old record + input current date and week +ENT】→ “X X X X X X”: 7 digits, means “year,
month, day and week”, e.g.:0701174, means Jan 17th, 2007, Thursday. (“0” means Sunday.)
【Auto Dialer#’s】:
Totally 5 telephone/mobile numbers
The first group is fixed for management center,other 4 groups are fixed for personal numbers
Press“▲▼” to select the report method: ”SMS Phone No.” for voice alarming, ”SMS reporting” for SMS text alarming
Notes: if you choose “SMS Reporting”, it will just sent to mobile numbers not include PSTN(landline) phone numbers.
Press ENT to confirm each phone(telephone/mobile) number
---【1: Call Center】:
【ENT + 1: Call Center + press “ ” to delete the old record + input the number you want to preset+ENT+ Press “▲▼” set as
Call by phone or SMS Reporting】
---【2: Personal Nbr】:
【Press ENT continously till you see “2: Personal Nbr” + press “ ” to delete the old record + input the number you want to
preset+ENT+ Press “▲▼” set as Call by phone or SMS Reporting】→ personal number is fixed from Group No. 2 to 5, press
ENT to set next personal number.
【Entry delay】:
【ENT + Entry Delay+ press “ ” to delete old record + X X + ENT】 → “X X”: 2 digits, you can set 00~59 seconds.
( default: “00”)
【Exit delay】:
【ENT + press “ ” to delete the old record + X X + ENT】 → “X X”: 2 digits,you can set 00~59 seconds.(default is: “15”)
【Siren On/Off】:
【ENT + Siren On/Off, press “▲▼” to choose ON or OFF. 】
If choose ON, the system will have alarm sound when alarm trigered. You need to setup the alarming delay time(seconds)
in the next sub-menus. Please do as following:
ENT +press “ ” to delete old record + input new time X X + ENT. You can set 00~60 minutes, the default is “03”
If choose OFF, just press ENT to confirm is ok. Then the system will not alarm when sensors trigered.
【Arm/Disarm Beep】:
ENT + Arm/Disarm Beep, press “▲▼” to choose YES or NO. The default set before shipment is “YES”.
【User ID】: