Hi-Tech GSM+PSTN Touch Screen Wireless Alarm System User Manual

User’s manual for GSM+PSTN Touch Screen Wireless Alarm System
I. Foreword
Thank you for purchasing and using GSM/PSTN LCD touch screen wireless home alarm system. This is a Hi-tech household security product. It will make your life safer and colorful. Please read the below information carefully before using for a proper usage.
II. Brief introduction of the Product
Alarm Host
Basic Accessories
Wireless Optional Accessories
GSM/PSTN LCD
Alarm Host
remote, wireless intelligent door sensor(or wireless door sensor) wireless wide-angle PIR sensor, , wireless indoor siren with sound and flash
gas alarm, smoke alarm, wireless keypad, wireless outdoor siren, doorbell button
Table 1: Product components
III. Function Features
1. Touch keypad; LCD displays Date, Day of the week, Time, and current Armed Status
2. Supported Languages: Simplified Chinese\ Traditional Chinese\ English\ German\ French\ and more to meet different market needs..
3. 2 /4 Band GSM/PSTN dual net-work. Support phone call alarm and SMS alarm, automatically switch to GSM dailing when telephone line is cut.
4. 29 wireless zones (Each zone supports up to 4 sensors) and 2 dedicated zones for remotes (Supports up to 4 remotes or wireless keypads per zone). Sipports 8 more wired zones(Optional).
5. Can preset up to 5 phone numbers and dial in sequence.
6. Intelligent logic analysis technology, corresponding zone number and sensor name can be displayed.
7. Record up to a 10 second greeting for the auto-dialer, Then play the greeting back.
8. Arm\ Disarm the system by 5 ways: SMS, Main Host(Keypad), Wireless Keypad, Keychain Remotes, or even remotely by phones. (PSTN alarm don‟t support SMS)
9. Available in AC\DC with Low-voltage Indicators
10. Learning sensors to alarm host, very easy operation.
11. Non-volatile chip, information stored automatically when off power.
12. Check door\window status automatically (This is when the system is disarmed only, if a door is opened, it will sound fast “bi bi bi”)
13. Support wireless “ding-dong” doorbell function (Optional)
14. Support CID uploading to CMS(Center monitoring Station) , can user our GSM CID connector to have this function.
15. Disconnection alarm, auto priority to occupy the telephone and monitoring function to hear what is happening.
16. Built-in Li-Ion backup battery, it will alert when low power or without external power supply.
17. Store up to 100 alarm records and 100 arm\disarm records
IV. Understanding of the Products
A. Understanding of the Alarm Host
/
Power /Signal
Low voltage
Status indicator
Emergency/Back Space
Number/Arm
Disarm/Delete/Esc
Confirm
Mic
Program
PgUp & PgDn
08.08 6
12 26 28
Connect antenna here
Front Side
Speaker
Backup battery ON/OFF
Power
Extend 8 wired zones here (Optional)
ON OFF
IN TEL
OUT
Tel out
Tel in
()
Connect wired siren here
Optional
Record
Play
SIM
SIM card slot
Back Side
1. Specifications:
Working power: AC=100~230V, DC=12V 1A  Static current:<50mA (when not charging) Alarm current:<500mA  Built-in Li-Ion backup battery: 3.7V 800mAH(rechargeable),  Standby: around 16 hours, Full charging time: 12 hours  2-Band GSM: GSM900/1800Mhz4-Band is optional: 850/900/1800/1900Mhz GSM transmit power: 2W  Receiving and emitting frequency: 433MHz  Working condition:
Temperature: -10ºC ~ 50ºC Humidity: 80%
Product dimension:150×107×26(mm)
2. Zone types and definitions
Zone types: Perimeter zone, Motion zone, Emergency zone  Definitions:
Perimeter zone: Detecting the space like doors, windows, etc., generally use wireless door magnet sensors and wireless curtain PIR sensors Motion zone: Detecting the space like living room, aisles and bedrooms, etc., generally use wireless wide-angle PIR sensors.
Emergency zone: Detecting the space like Emergency area (such as emergency distress, medical rescue, gas leakage and fire alarm, etc., this zone keep 24-hour monitoring status automatically. Generally use panic button, wireless gas sensors and wireless smoke sensors.
3. Modes of arming
Away Arm” modeOnce any detectors in perimeter zones or motion zones get triggered, the host will alarm immediately and
meantime dial “#” automatically.
Home Arm” modeOnce any detectors in perimeter zones get triggered, the host will alarm immediately and meantime dial #
automatically. It will not alarm after any detectors in the motion zone are triggered.
4. How to operate the alarm host Preparation
1. Insert SIM card properly.
2. Fix the antenna
3. Connect the telephone cable: connect the telephone cable of telecommunication to Tel in port on the alarm host, then use the telephone cable attached in the package to connect Tel out port and telephone set.
4. Connect power: connect the power adaptor to DC port of the alarm host first, then plug it to the AC socket.
5. Turn on the backup battery
6. Check and see if GSM signal is good enough
Type
GSM Signal OK
Signal is not normal or SIM card not
inserted properly
2-Band
900/1800 MHZ
Signal indicator keeps flash about
every 2 seconds
Signal indicator keeps on
4-Band
850/900/1800/900 MHZ
Signal indicator keeps flash about
every 3 seconds
Signal indicator keeps flash about
every 1 seconds
Signal level status
When standby, press“▲”or“▼”and you can see the signal status as below. XX: 0 …..31 indicates the signal from weak to strong,99 indicates unknown.
YY: Indicates signal status, OK is good, No is a little weak and need to adjust installation position. Press ESC to get back for standby status. Or get back to standby status automatically after 30 seconds without no operation.
Note: If SIM card is not insert properly, it will shows:
How to program
Notes:
The host will exit programming mode if without any operation within 30 seconds  It will exit to the previous menu if press ESC If enter codes by mistake for 3 times, the host panel will resume to the standby mode  you can press “▲▼” to adjust programming info. Or to find alarming info.
1. Menu preview
Main menu
Sub-Menu1
Sub-Menu2
Sub-Menu3
Sub-Menu4
Sub-Menu5
Remark
Set Time
Set time
Hour/minute/second
Set Date
Set Date
Year/Month/Day/Week
Auto-dialer#‟s
Call Center Personal Nbr
Call by phone SMS reportng
Alarming phone number, Group 2~5 for personal
Entry Delay
Entry delay
Time delay for enter
Exit Delay
Exit Delay
Time delay for exit
Siren On/Off
Siren off Siren on
Emergency siren
Perimeter siren
Motion siren
Duration time of alarming sound
Signal Level:
XX YY
NO SIM CARD:
XX YY
Arm/Disarm Beep
Arm/Disarm Beep Yes No
No need to setup for personal use
User Id
Enter Usercode
No need to setup for personal use
Upload Satus?
Upload status? Yes No
No need to setup for personal use
CutWire Alarm?
CutWire Alarm? Yes No
Only applicable for PSTN
Zone Attribute
Zone number XX
XX Zone type 2 1 0
Alarm Type XX
Bypass Zone? Yes No
Entry Delay Set?
Yes No
Needed when adding wireless sensors
Set Smart Zone
Zone number
Smart Sensor ON Yes No
Smart Sensor ON? Yes No
Zone Indicator Yes No
Detect and indicate open/close states of doors/windows
Program Sensor
Zone number
Group Number
ActivateSensor Delete Sensor
For Adding or deleting wireless sensor
Wireless Code
Wireless Code
Usually no need for users
Alarm History
XX: Button Call Failed
XX: 01.01 00:08:52
For checking alarming history records.
Status History
DISARM 00:
01.01 03:39
For checking working records
Table 2: Menu Preview
2. Detailed program instructions:
For any program, you should start withSET + Enter code + input the 6-digit code (default: 888888)+ENT
Set time】: 【ENT + press to delete the old record + input current time+ENT】→ “X X X X X X”: 6 digits, means “hour, minute, second,
each takes 2 digits space, e.g. you may press 142120, now the host time will be 14:21:20.
Set date】: 【ENT + press to delete the old record + input current date and week +ENT】→ “X X X X X X”: 7 digits, means “year, month, day and week, e.g.:0701174, means Jan 17th, 2007, Thursday. (“0” means Sunday.) 【Auto Dialer#’s】:
Totally 5 telephone/mobile numbers  The first group is fixed for management centerother 4 groups are fixed for personal numbers  Press“▲▼” to select the report method: ”SMS Phone No.” for voice alarming, ”SMS reporting” for SMS text alarming  Notes: if you choose “SMS Reporting”, it will just sent to mobile numbers not include PSTN(landline) phone numbers.  Press ENT to confirm each phone(telephone/mobile) number
---【1: Call Center】:
ENT + 1: Call Center + press to delete the old record + input the number you want to preset+ENT+ Press “▲▼” set as
Call by phone or SMS Reporting
---2: Personal Nbr: Press ENT continously till you see 2: Personal Nbr+ press to delete the old record + input the number you want to preset+ENT+ Press “▲▼” set as Call by phone or SMS Reporting personal number is fixed from Group No. 2 to 5, press ENT to set next personal number.
Entry delay】:
ENT + Entry Delay+ press to delete old record + X X + ENT→ “X X”: 2 digits, you can set 00~59 seconds.
( default: “00”)
Exit delay】:
ENT + press to delete the old record + X X + ENT→ “X X”: 2 digits,you can set 00~59 seconds.(default is: 15)
Siren On/Off】:
ENT + Siren On/Off, press “▲▼” to choose ON or OFF.
If choose ON, the system will have alarm sound when alarm trigered. You need to setup the alarming delay time(seconds) in the next sub-menus. Please do as following: ENT +press to delete old record + input new time X X + ENT. You can set 00~60 minutes, the default is “03”
If choose OFF, just press ENT to confirm is ok. Then the system will not alarm when sensors trigered. Arm/Disarm Beep】: ENT + Arm/Disarm Beep, press “▲▼” to choose YES or NO. The default set before shipment is YES.