Hitachi uc 24yfb Technical Data And Service Manual

POWER TOOLS
TECHNICAL DATA
AND
SERVICE MANUAL
CHARGER
UC 24YFB
SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT
U
MODEL
UC 24YFB
Notice for use
Specifications and parts are subject to change for improvement.
Refer to Hitachi Power Tool Technical News for further information.
Page
CONTENTS
1. PRODUCT NAME ........................................................................................................................... 1
2. MARKETING OBJECTIVE ............................................................................................................. 1
3. APPLICATIONS.............................................................................................................................. 1
4. SELLING POINTS .......................................................................................................................... 2
4-1. Selling Point Descriptions ............................................................................................................... 3
5. SPECIFICATIONS .......................................................................................................................... 7
5-1. Specifications.................................................................................................................................. 7
5-2. Comparisons with Similar Products ................................................................................................ 7
6. PRECAUTIONS IN SALES PROMOTION ..................................................................................... 8
6-1. Safety Instructions .......................................................................................................................... 8
6-2. Extra Precautions in Sales Promotion ............................................................................................ 9
7. QUESTIONS AND ANSWERS ON MODEL UC 24YFB .............................................................. 10
8. GENERAL PRECAUTIONS ......................................................................................................... 12
8-1. Model UC 24YFB .......................................................................................................................... 12
8-2. Pilot Lamp Indications................................................................................................................... 13
9. PRECAUTIONS IN DISASSEMBLY AND REASSEMBLY .......................................................... 14
9-1. Disassembly ................................................................................................................................ 14
9-2. Reassembly .................................................................................................................................. 14
9-3. Confirmation after Reassembly .................................................................................................... 14
10. TROUBLESHOOTING GUIDE ................................................................................................... 15
10-1. Troubleshooting Based on Pilot Lamp Indications ...................................................................... 15
10-2. Troubleshooting and Repair Procedures .................................................................................... 15
11. STANDARD REPAIR TIME (UNIT) SCHEDULES...................................................................... 19
Assembly Diagram for UC 24YFB ....................................................................................................... 20
1
1. PRODUCT NAME
Hitachi Charger, Model UC 24YFB
2. MARKETING OBJECTIVE
As the cordless tool market expands year by year, customers have come to expect a wider range of high-voltage products with excellent appearance, operability and durability. To satisfy these needs, it is necessary to develop slide-in battery packs as well as the conventional plug-in battery packs, and corresponding chargers and multi­purpose cordless tools featuring the following:
Improved operability and appearance designed free from the handle shape constraints
Improved stability in mounting battery packs to cordless tools and improved stability in electric contact The Model UC 24YFB Charger that has been developed to meet these needs is capable of recharging either a 24 V slide-in nickel cadmium (Ni-Cd) battery or a 24 V slide-in nickel metal hydride (Ni-MH) battery in about one hour. The rechargeable range is from 7.2 V to 24 V to correspond to the future slide-in battery packs.
3. APPLICA TIONS
Recharging of Hitachi batteries Applicable batteries:
Ni-Cd battery EB 2420 [24 V, 2.0 Ah] Ni-MH battery EB 2430HA [24 V, 3.0 Ah]
2
4. SELLING POINTS
(1) Accepts both Ni-MH and Ni-Cd batteries (2) Rapidly charges Hitachi EB 2420 and 2430 HA batteries
Charging time:
24 V, 2.0 Ah
•••••••••
50 minutes
24 V, 3.0 Ah
•••••••••
70 minutes
(3) Hitachi original charge control mechanism for longer battery life
EB 2420 EB 2430HA
Easy-to-read visual display of charging status through constant lighting or flashing of red and green pilot lamps
3-way overcharging protection systems for longer battery and charger life
Fig. 1
Recharging/discharging cycles of battery (ambient temperature range between 10 ˚C and 30 ˚C)
Ni-Cd: about 1,000 times
Ni-MH: about 500 times
3
4-1. Selling Point Descriptions
4-1-1. Capable of handling both nickel cadmium (Ni-Cd) and nickel metal hydride (Ni-MH) batteries
Through application of HITACHI-microcomputer and electronic-circuit control technology, Model UC 24YFB is capable of handling both Ni-Cd and Ni-MH batteries.
4-1-2. Rapidly charges Hitachi EB 2420 and 2430 HA batteries
Table 1 Recharging time (approx. min.) at 20 ˚C
Battery voltage
Battery capacity
24 V
3.0 Ah
EB2430HA
70 min.
2.0 Ah
EB2420 50 min.
NOTE: The recharging time may vary depending on the ambient temperature and the power supply voltage. : Ni-MH batteries
4-1-3.Recharging/discharging cycles of battery (ambient temperature range between 10˚C and 30˚C)
Ni-Cd battery: about 1,000 times Ni-MH battery: about 500 times
4-1-4. Capable of recharging batteries with internal temperatures as high as 60 ˚C
When a battery with S terminal is used, as shown in Fig. 2, the 60 ˚C thermistor operates to permit recharging of batteries heated up to 60 ˚C, and as shown in Fig. 3, the 55 ˚C thermistor operates heated up to 55 ˚C.
(Note 1) Wiring diagrams for batteries are shown below.
The 95 ˚C thermal protector in the batteries EB 2420 and 2430 HA interrupts the recharging circuit when the battery temperature reaches 95 ˚C.
A discriminating resistor is provided in Ni-MH batteries EB 2430HA and EB 2430H to distinguish them from Ni-Cd batteries.
Because Ni-MH battery EB 2430HA is heated to high temperatures during recharging, this charger operates within a range of a 10 ˚C temperature difference between the maximum battery temperature when starting recharging (45 ˚C) and the temperature when stopping recharging (55 ˚C).
4
60 ˚C Thermistor
95 ˚C Thermal protector
Terminal
--
Terminal
+
Terminal
--
Terminal
S
Fig. 2 Ni-Cd battery (EB 2420)
Terminal position
Fig. 3 Ni-MH battery (EB 2430HA)
Terminal
--
Terminal
+
Terminal
S
Terminal
--
Terminal
T
95 ˚C Thermal protector
55 ˚C Thermistor
Discriminating resistor
Terminal position
5
Battery voltage
Battery internal gas pressure
Battery temperature
Battery voltage
2
V
Overcharge range
60˚C Thermistor 40˚C Thermostat
30~60-Minute timer
Ni-Cd Battery temperature
Charging time
Battery internal gas pressure
55˚C Thermistor
dT/dt
Ni-MH Battery temperature
4-1-5. 3-way overcharge protection system
Overcharge protection is ensured by a (A) system or dT/dt system (for Ni-MH battery), (B) built-in battery temperature sensors (thermostat and thermistor) and (C) a timer.
Fig. 4 Relationships of time, voltage, temperature and gas pressure while charging
(A) : This detects the increase in battery voltage at the end of charging using the value and suspends
charging. dT/dt : This system is applicable to Ni-MH batteries. This detects the variation of Ni-MH battery temperature by the value dT/dt at the end of charging and suspends charging.
(B) Built-in battery temperature sensors : In the event the system fails to detect the voltage change,
the 40 ˚C thermostat or the 60 ˚C thermistor stops charging when battery temperatures reach their respective values.
(C) Timer : Should both the system, dT/dt system and the temperature sensors fail, the timer automatically
stops charging within 120 minutes from the beginning of charging.
(Note 2) The voltage of the battery increases during charging and begins to fall when further charging is not
possible. The system detects the point where the voltage begins to fall, and suspends charging to protect the battery from overcharging.
(Note 3) The temperature rise during charging of a Ni-MH battery is higher than with a Ni-Cd battery, and a
sudden temperature rise occurs just before the battery is fully charged. The dT/dt system detects the point where the temperature rises suddenly and suspends charging to minimize the temperature rise.
(Note 4) As shown in Fig. 7, the pressure of gas generated after a battery has become fully charged rises
rapidly to cause high temperature and high gas pressure that degrade the effectiveness of the battery. If charging is allowed to continue, the pressure of the gas will activate the safety valve in the battery, and the electrolyte will begin leaking.
6
4-1-6. Easy-to-read visual display of charging status through constant lighting or flashing of red and green pilot
lamps
Prior to charging
Red pilot lamp remains lit or flashes
Blinks
0.5 sec. ON 0.5 sec. OFF
During charging
Charging completed
Lights
Blinks
Charging not possible
Flickers
Green pilot lamp is lit
High battery temperature
Lights
Stays ON constantly
0.5 sec. ON 0.5 sec. OFF
0.1 sec. ON 0.1 sec. OFF
Stays ON constantly
Battery or charger is faulty.
Charging not possible because battery temperature is too high.
Pilot lamp indications
Battery Type
Battery temperature range during charging
Charging of heated (high temperature) batteries
Heated (high temperature) battery
EB 2420 ---5 ˚C --- 60 ˚C
Green pilot lamp lights. When battery temperature is reduced to 60 ˚C, green pilot lamp goes OFF and charging begins.
EB 2430HA
0 ˚C --- 45 ˚C
Green pilot lamp lights. When battery temperature is reduced to 45 ˚C, green pilot lamp goes OFF and charging begins.
7
5. SPECIFICATIONS
5-1. Specifications
Descriptions
Item
AC single-phase, 50 Hz or 60 Hz 90 W Constant current charge with feedback control
(1) Battery voltage detection ( system) for Ni-Cd battery Ni-MH battery temperature detection (dT/dt system) for Ni-MH battery (2) Battery surface temperature detection (thermostat or thermistor) (3) 120 minutes timer
24 V
0.6 kg 0 ˚C --- 40 ˚C
Power source
Charging system Overcharging protection system
Charging voltage Charging current Charging time Product weight Operating ambient
temperature range
5-2. Comparisons with Similar Products
Power input
2.5 A Approx. 50 minutes (for Ni-Cd 2.0 Ah, 24 V)
(*1): Chargeable Ni-Cd battery temperature range (*2): Chargeable Ni-MH battery temperature range
HITACHI
UC 24YFB
Charging time
Overcharge protection system
Charging voltage
min. 50
(EB 2420)
V
24 Charging current A 2.5 Power input VA 120 V, 1.5 A
Operating ambient temperature range
˚C
0 --- 40
Chargeable battery temperature range
˚C (*1) ---5 --- 60
(*2) 0 --- 45
---
system, dt/dt system, battery surface temperature detection, timer
External dimensions (length x width x height)
mm
226 x 110 x 75
Weight kg 0.6 (1.3 lbs.)
D
50
(2.0 Ah, 24 V Ni-Cd)
24
2.5
120 V, 2.2 A
4.5 --- 40.5
Peak cut
165 x 201 x 56
0.6 (1.3 lbs.)
4.5 --- 40.5
8
6. PRECAUTIONS IN SALES PROMOTION
6-1. Safety Instructions
In the interest of promoting the safest and most efficient use of the Model UC 24YFB Charger by all of our customers, it is very important that at the time of sale the salesperson carefully ensures that the buyer seriously recognizes the importance of the contents of the Handling Instructions.
6-1-1. Handling instructions
Salespersons must be thoroughly familiar with the contents of the Handling Instructions in order to give pertinent advice to the customer. (1) Connect the charger to an AC power outlet only.
Use of any other power source (DC outlet, fuel-powered generator, etc.) will cause the charger to overheat and burn out.
(2) Do not use any voltage-increasing equipment (transformer, voltage regulator, etc.) between the power source
and the charger. If the charger is used with voltage over and above that indicated on the unit, it will not function properly.
(3) Conduct battery charging in an ambient temperature range of 0 ˚C --- 40 ˚C.
If charging is attempted when the ambient temperature is below 0 ˚C, overcharging occurs because the thermistor and thermostat do not function properly, thereby reducing the service life of the battery. While it is possible to charge batteries with an S terminal at higher temperatures, the service life of the batteries may be considerably reduced.
(4) Do not use the charger for successive charging.
In very hot locations, if two or more batteries are charged successively the temperature of the charger will rise excessively, and might cause the charger to fail. Instruct the customer to wait at least 15 minutes before commencing next charging. Particular care is necessary in summer or tropical countries when the power source voltage is high.
(5) Do not insert foreign objects into the air vent on the charger.
The charger case is equipped with air vents to protect the internal electronic components from overheating. Caution the customer not to allow foreign materials, such as metallic or inflammable objects, to be dropped or inserted into the air vents. This could cause electrical shock, fire or other serious hazards.
(6) Do not attempt to disassemble the charger.
Incorrect parts replacement and/or wiring will cause malfunctions which could result in fire or other hazards. Instruct the customer to bring the charger to an authorized service center in the event repair or replacement is necessary.
9
6-2. Extra Precautions in Sales Promotion
The following points must be given during sales promotion.
6-2-1. Charging may not be possible when the battery temperature is high
Charging may not be possible if the temperature of the battery is high after it has been exposed to direct sunlight for a long time or immediately after it has been used. The customer should be advised in such a case to place the battery in a shaded area with good airflow, and allow sufficient cooling before recharging. This phenomenon is common to all existing batteries and chargers which employ temperature sensitive overcharge protection devices. The cooling time required before recharging varies from a few minutes to about 30 minutes, depending on the load, duration of use and ambient temperature.
10
7. QUESTIONS AND ANSWERS ON MODEL UC 24YFB
Q1 What are typical charging methods?
A1 The most recent electronic charging methods are outlined below.
Battery voltage
Charging time
Voltage variation factor immediately before battery becomes fully charged is detected, and charging is automatically suspended.
Charging method
Method A UC 12Y
UC 12YA
Method B UC 24YFA
UC 24YFB UC 24YC UC 24YF UC 14YF2 UC 14YF UC 12YF UC 12YD UC 12YB
dT/dt Charging method
Method C UC 24YFA
UC 24YFB UC 24YC
Battery voltage
Charging time
The descending voltage ( --- ) of the battery in the final stage of charging is detected, and charging is automatically suspended.
--- Charging method
Battery temperature
Charging time
dT/dt
Sudden temperature rise just before full charging is detected and charging is suspended (Ni-MH battery)
11
Q2 Why was the microcomputer control system adopted for the Model UC 24YFB?
A2 If charging is continued after the battery has been fully charged, it will cause a large amount of oxygen gas
(O2) to be generated in a short period of time, as shown below. This proportionately accelerates degradation of the plates. The microcomputer control system was adopted for the Model UC 24YFB charger in order to stop charging immediately before the battery is fully charged, thereby avoiding the generation of oxygen gas. This charging method applies no stress to the batteries.
Anode plate
Up to full charge. (Charging proceeds almost without deviation.)
Charged portion Uncharged portion
Plates
Separator
Cathode plate
O
2
O
2
O
2
Oxygen gas is generated when full charge is reached. (Anode is fully charged.)
Enters overcharge state and begins gas degradation with the cathode.
Anode plate
Cathode plate
Cathode plate
Anode plate
O2O2O
2
Q3 What is the difference between the microcomputer control system and the dT/dt system?
A3 Both systems cut off charging at almost the same point before the battery becomes fully charged.
The microcomputer control system detects a sudden voltage change which occurs just before the battery is fully charged and then suspends charging. The dT/dt system detects a sudden temperature rise which occurs just before the battery is fully charged and then suspends charging.
Q4 Is there any difference in the amount of work possible per charge of batteries charged with the
microcomputer control system and those charged with dT/dt microcomputer control system?
A4 The dT/dt microcomputer control system may have a slightly shorter charging capacity (approx. 3 to 5 %).
However, the amount of work possible per charge varies widely depending on the ambient temperature, the efficiency with which the battery charge is used, etc., so that there is essentially no difference between batteries charged with either system.
Q5 The battery charger is supposed to be used within a temperature range of 0 to 40 ˚C.
What happens if it is used for charging at under 0 ˚C or above 40 ˚C?
A5 At temperatures of under 0 ˚C, battery overcharge will occur, resulting in damage to the battery plates
because the plates may not function properly. At temperatures over 40 ˚C, sufficient charging cannot be attained, or the plates will be damaged and the recharging/discharging cycles of the batteries will be reduced by half compared to low-temperature charging, even if the battery is fully recharged.
12
Case (A)
8. GENERAL PRECAUTIONS
8-1. Model UC 24YFB
(1) The outer frame consists of case (A) and case (B). Inside the frame there are the print circuit board and
terminals.
(2) The print circuit board consists of high-frequency power transformer, microcomputer and other electronic
devices to permit rapid charging and to protect against overcharging.
Case (B)
Printed circuit board
Terminal
Case (A)
Case (B)
13
8-2. Pilot Lamp Indications
Battery Type
Battery temperature range
during charging
Pilot lamp indications during charging of heated (high temperature) batteries
Heated (high temperature) battery
EB 2420 - --5 ˚C --- 60 ˚C
Green pilot lamp lights. When battery temperature is reduced to 60 ˚C, green pilot lamp goes OFF and charging begins.
EB 2430H
0 ˚C --- 45 ˚C
Green pilot lamp lights. When battery temperature is reduced to 45 ˚C, green pilot lamp goes OFF and charging begins.
Prior to charging
Red pilot lamp remains lit or flashes
Blinks
0.5 sec. ON 0.5 sec. OFF
During charging
Charging completed
Lights
Blinks
Charging not possible
Flickers
Green pilot lamp is lit
High battery temperature
Lights
Stays ON constantly
0.5 sec. ON 0.5 sec. OFF
0.1 sec. ON 0.1 sec. OFF
Stays ON constantly
Battery or charger is faulty.
Charging not possible because battery temperature is too high.
Pilot lamp indications
14
9. PRECAUTIONS IN DISASSEMBLY AND REASSEMBLY
The [Bold] numbers in the descriptions below correspond to the item numbers in the Parts List and exploded assembly diagram for UC 24YFB.
9-1. Disassembly
(1) Remove the four Tapping Screws (W/Flange) D3 x 20 [6] and take off Case (A) [2].
The Printed Circuit Board Ass'y [4] and the Cord [9] can then be taken out in an assembled body.
(2)
To separate the Printed Circuit Board Ass'y [4] and the Cord [9], melt the soldered portions with a soldering iron.
(NOTE) Ideally, the soldered portions should be free with a solder absorber. If a soldering iron must be used,
use one with a rated power of 35 W.
9-2. Reassembly
Reassembly can be accomplished by following the disassembly procedures in reverse; however, special attention should be given to ensure that lamps, cord armor and charging terminals are properly installed in their prescribed grooves.
9-3. Confirmation after Reassembly
(1) Confirm the following when the battery is fully charged.
Confirm that the red pilot lamp on the charger lights up.
When charging an EB 2430H battery, confirm that the red pilot lamp flashes at 1 second intervals approx. 60 minutes from commencing charging.
(2) Measure the insulation resistance and conduct a dielectric strength test.
Insulation resistance:10 M or more between the plug blade of cord and the Name Plate or case fastening
screws, with DC 500 V Megohm Tester.
Dielectric strength test: (a) Between the plug blade of cord and the charging terminal blade. (b) Between the plug blade of cord and the Name Plate or fastening screws on the case.
Based on the voltage listed on the Name Plate, dielectric strength test should be conducted.
CAUTION: Without fail, insulation resistance must be measured between the plug blade of cord and the
Name Plate or fastening screws, and dielectric strength test must be conducted between the plug blade of cord and the charging terminal blade or between the plug blade of cord and the Name Plate or fastening screws on the case. Under no circumstances should testing be conducted between both blades of the plug, or both blades of the charging terminal, which may cause burn-out of the charger.
Voltage on the name plate Test voltage
120 V 230 V, 240 V
AC 1,240 V (1 minute) AC 3,750 V (1 minute)
15
10. TROUBLESHOOTING GUIDE
10-1. Troubleshooting Based on Pilot Lamp Indications
Phenomenon
Pilot lamp fails to light or flash.
Red pilot lamp does not stay lit (continues to flicker) after battery has been connected.
Pilot lamp remains green (red fails to light) after battery has been connected.
Pilot lamp indicates abnormality by flashing red rapidly (at 0.2 second intervals).
(1) Faulty AC cord (2) Blown fuse (3.15 A) on primary side
(1) Poor connection of (T) or (S) terminal (2) Faulty battery (open circuit) (3) Faulty PCB
(1) Poor connection of (T) or (S) terminal (2) Faulty PCB
(1) Faulty battery (short-circuit, or open circuit) (2) Faulty PCB
Typical causes
Refer to trouble mode (A).
Check procedures
Refer to trouble mode (B).
Refer to trouble mode (C).
Refer to trouble mode (D).
NO
NO
NO
NO
NO
YES
YES
YES
YES
Pilot lamp fails to light or flash.
Apply rated voltage.
Is rated
voltage applied
to the plug ?
Is there
continuity between
the blades of the
AC cord plug ?
Is there
an open circuit in
the AC cord ?
Is the fuse
on the primary side
Blown ?
Replace PCB.
Faulty internal circuit
Replace PCB.
Replace the AC cord.
Faulty internal circuit
Check with tester.
Replace the fuse.
10-2. Troubleshooting and Repair Procedures
(1) Trouble mode (A)
16
(2) Trouble mode (B)
NO
Check with tester.
NO
YES
YES
Red pilot lamp does not stay lit (continues to flash) after battery has been connected.
Are the connection terminals
of the charger or the battery dirty, deformed,
or otherwise abnormal ?
Faulty internal circuits
Replace PCB.
Remove dirt or correct abnormality.
Replace the battery.
Is the resistance
between (S) and (---) terminals
2K
to
100 K
?
17
(3) Trouble mode (C)
NO
NO
YES
YES
YES
YES
NO
Is ambient temperature
within designated range (between
0˚C and 40˚C) ?
Is the
battery very
hot ?
Are the connection
terminals of the charger
or the battery dirty or
deformed ?
Is the resistance
between (S) and (---) terminals
2K
to
100 K
?
Faulty internal circuits
Replace PCB.
Pilot lamp remains green (red fails to light) after battery has been connected.
Allow battery to cool prior to charging
NO
Conduct charging within designated temperature range.
0 ˚C
---
40 ˚C
Clean, or repair deformed terminals.
For EB 2420, charging cannot be accomplished if battery temperature is above 60˚C. For EB 2430HA, charging cannot be accomplished if battery temperature is above 45˚C.
Replace battery.
18
(4) Trouble mode (D)
NO
Pilot lamp flickers red, indicating abnormality.
YES
Remove foreign matter.
Is there some
sort of conductive foreign
matter in the hole where the
battery is inserted ?
NO
NO
YES
Replace the battery.
Is the battery short-circuited
or opened ?
Replace PCB.
Faulty internal circuit
19
11. STANDARD REPAIR TIME (UNIT) SCHEDULES
MODEL 10 20 30 40
Fixed
Variable
UC 24YFB
Work Flow
Case (A) Fuse (3.15 A) Light Bar
60 min.
50
Case (B) Printed Circuit
Board Ass'y
Cord
General Assembly
ELECTRIC TOOL PARTS LIST
LIST NO.
CHARGER Model UC 24YFB
2001 • 1•30
(E1)
F846
*
ALTERNATIVE PARTS
--- 2 ---
ITEM
NO.
CODE NO.
DESCRIPTION REMARKS
NO.
USED
PARTS
Printed in Japan (010130N)
1 -- 01
UC 24YFB
1 HITACHI LABEL 1
2 319-935 CASE (A) 1 * 3 319-781 FUSE (125V-3.15A) 1 FOR 120V * 3 319-780 FUSE (250V-3.15A) 1 FOR 230V-240V * 4 319-937 PRINTED CIRCUIT BOARD ASSY 120V 1 INCLUD.3 * 4 319-938 PRINTED CIRCUIT BOARD ASSY 230V-240V 1 INCLUD.3
5 319-936 CASE (B) 1
6 300-036 TAPPING SCREW (W/FLANGE) D3X20 4
7 NAME PLATE 1
8 319-934 LIGHT BAR 1 * 9 318-262 CORD 1 * 9 318-259 CORD 1 FOR USA * 9 318-261 CORD 1 FOR GBR * 9 318-260 CORD 1 FOR AUS
Loading...